A Passive Optical Fiber Anemometer for Wind Speed Measurement on High-Voltage Overhead Transmission Lines

被引:42
|
作者
Ma, Guo-Ming [1 ]
Li, Cheng-Rong [1 ]
Jiang, Jian [1 ]
Liang, Jun-Yu [2 ]
Luo, Ying-Ting [1 ]
Cheng, Yang-Chun [1 ]
机构
[1] N China Elect Power Univ, Beijing Key Lab High Voltage & Elect Compatibil, Beijing 102206, Peoples R China
[2] N China Elect Power Univ, Thermal Energy & Power Engn, Beijing 102206, Peoples R China
关键词
Anemometer; fiber Bragg grating (FBG); overhead transmission lines; quasi-distribution measurement; BRAGG GRATING SENSORS; POWER-LINES; TEMPERATURE; LOADS;
D O I
10.1109/TIM.2011.2164837
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurement of wind speed is an essential part of overhead transmission line monitoring. To overcome the drawbacks of the existing anemometer, such as the requirement on field power, the sensitivity to electromagnetic interference, and the unavailability of real-time measurement, a novel anemometer is developed on the basis of the fiber Bragg grating (FBG) sensing technique. In the anemometer, a beam with uniform strength was used to measure the force generated by the wind; two naked FBGs were symmetrically glued on the upper and lower surfaces of the beam to solve the problem of cross-sensitivity between strain and temperature of FBG sensing. Furthermore, the temperature effect on the zero output was investigated by putting the FBG anemometer into a temperature-controlled cabinet, and the experimental results indicated that the temperature effect on the zero output of the wind speed was less than +/- 5 pm (-10 degrees C to 50 degrees C). The results from the wind tunnel experiment indicated that the measurement error of the anemometer was less than +/- 0.5 m/s.
引用
收藏
页码:539 / 544
页数:6
相关论文
共 50 条
  • [21] Capillary Optical Fiber Sensor for Real-Time Monitoring of High-Voltage Transmission Lines Sag
    Zhang Xiaodong
    Zhu Xiaoliang
    Yu Yao
    Chen Jiayi
    Sun Zecheng
    LASER & OPTOELECTRONICS PROGRESS, 2022, 59 (07)
  • [22] Effect of the Ground on High-Frequency Transmission Characteristics of Overhead High-Voltage Power Lines.
    Slaninka, Pavel
    Svst, Ef
    Elektrotechnicky obzor, 1984, 73 (09): : 492 - 498
  • [23] Monitoring the magnetic field in houses under 50 Hz high-voltage overhead transmission lines
    Decat, G
    Van Tongerloo, J
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 1998, 9 (04) : 341 - 351
  • [24] ULTRA-HIGH VOLTAGE OVERHEAD TRANSMISSION LINES
    ALEKSANDROV, GN
    ELECTRICAL TECHNOLOGY RUSSIA, 1971, 1 : 1 - +
  • [25] Adult Cancers Near High-voltage Overhead Power Lines
    Elliott, Paul
    Shaddick, Gavin
    Douglass, Margaret
    de Hoogh, Kees
    Briggs, David J.
    Toledano, Mireille B.
    EPIDEMIOLOGY, 2013, 24 (02) : 184 - 190
  • [26] METHOD FOR SIMULTANEOUS MEASUREMENT OF CURRENT AND VOLTAGE ON HIGH-VOLTAGE LINES USING OPTICAL TECHNIQUES
    SANDERSON, JVH
    BROWN, CW
    ROGERS, AJ
    PAYMAN, R
    STALEWSKI, A
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1977, 124 (11): : 992 - 994
  • [27] Plastic Composite Insulators for High-Voltage Overhead Lines.
    Pargamin, Laurent
    Huc, Jean
    Elektrizitatswirtschaft, 1980, 79 (08): : 290 - 293
  • [28] METHOD FOR SIMULTANEOUS MEASUREMENT OF CURRENT AND VOLTAGE ON HIGH-VOLTAGE LINES USING OPTICAL TECHNIQUES
    ROGERS, AJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1976, 123 (10): : 957 - 960
  • [29] Wind speed measurement with a low-cost polymer optical fiber anemometer based on Fresnel reflection
    Gucyetmez, Mehmet
    Keser, Serkan
    Hayber, Sekip Esat
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 339
  • [30] ON EFFECTS OF HIGH-VOLTAGE TRANSMISSION-LINES
    BANKS, RS
    WILLIAMS, AN
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1984, 74 (09) : 1042 - 1042