High power test of CVD diamond window for ECRH system in SST-1

被引:0
作者
Shukla, B. K. [1 ]
Babu, Rajan [1 ]
Kushwah, Mahesh [1 ]
Sathyanarayana, K. [1 ]
Patel, Jatin [1 ]
Rao, S. L. [1 ]
Pragnesh, D. [1 ]
Patel, Harshida [1 ]
Belsare, S. [1 ]
Vipal, R. [1 ]
Patel, Satish D. [1 ]
Vishal, B. [1 ]
Priyanka, A. S. [1 ]
Anjali, S. [1 ]
Ronak, S. [1 ]
Shmelev, Mikhail [2 ]
Belov, Yury [2 ]
Belousov, Vladimir [2 ]
机构
[1] Inst Plasma Res, Gandhinagar 382418, Gujarat, India
[2] Inst Appl Phys, Nizhnii Novgorod, Russia
来源
2011 IEEE/NPSS 24TH SYMPOSIUM ON FUSION ENGINEERING (SOFE) | 2011年
关键词
component; CVD diamond window; ECRH; Gyrotron; matching optic unit;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
High power tests on CVD diamond window are carried out using 82.6GHz Gyrotron. In order to test CVD diamond window with calorimetric dummy load, a matching optic unit is designed and fabricated with special profiled mirrors. The mirrors are fabricated by M/s. Gycom Russia and a mirror box assembly is fabricated at IPR. The mirrors and mirror box are cooled with water. The mirror box consists of four arc detectors for the protection of window. The CVD diamond window is connected to dummy load with this mirror box. The alignment of mirror is done during the testing of CVD window in pulsed condition. After achieving the desired Gaussian pattern at the exit of mirror box, system is connected to dummy load for CW test. The CVD window is tested up to 60kW power for 10minutes.
引用
收藏
页数:4
相关论文
共 24 条
  • [21] Design of control system for all solid anode high-voltage power supply based on pulse step modulation for ECRH
    Rao Y.-H.
    Chen W.-G.
    Hu B.
    Rao J.
    Feng K.
    Kang Z.-H.
    Chen, Wen-Guang (tocwg6666@126.com), 1600, Atomic Energy Press (50): : 2276 - 2282
  • [22] Development of a Wide-Band Window in HE1,1 Waveguide for High Power Gyrotrons
    Read, Michael
    Bui, Thuc
    Marsden, David
    Collins, George
    Ives, R. Lawrence
    IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2014, : 433 - 434
  • [23] High power test of a temperature controlled diplexer for electron cyclotron current drive system
    Saigusa, Mikio
    Sekiguchi, Kenji
    Honzu, Toshihiko
    Mori, Junnya
    Shozu, Hiroki
    Oda, Yasuhisa
    Ikeda, Ryosuke
    Takahashi, Koji
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 385 - 389
  • [24] Experimental study of high-power millimeter wave transmission of sapphire window for electron cyclotron range of frequencies system
    Kasugai, A
    Takahashi, K
    Sakamoto, K
    Yamamoto, T
    Tsuneoka, M
    Kariya, T
    Imai, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5A): : 2883 - 2887