Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time

被引:3
作者
Xiang, Haiyan [1 ]
Liu, Yanyong [1 ]
Li, Yinhua [1 ]
Qin, Yufei [1 ]
Yu, Mengsun [1 ]
机构
[1] Inst Aviat Med, Beijing 100142, Peoples R China
关键词
beat-to-beat; blood pressure; Korotkoff sound delay time; noninvasive measurement; transmural pressure; PULSE ARRIVAL-TIME; TRANSIT-TIME; ACCURACY; GENESIS;
D O I
10.1097/MBP.0b013e32834f710b
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To propose a novel noninvasive beat-to-beat arterial blood pressure measurement method based on the Korotkoff sound delay time (KDT) and evaluate its accuracy in preliminary experiments. Methods KDT decreases as the cuff pressure P deflates, which can be described by a function KDT = f(P). Actually, KDT is a function of arterial transmural pressure. Therefore, the variation in blood pressure can be obtained by the transmural pressure, which is estimated by the KDT. Holding the cuff pressure at an approximate constant pressure between systolic pressure and diastolic pressure, the variation in blood pressure Delta EBP between successive heartbeats can be estimated according to KDT and f'(p), which represents the variation of KDT corresponding to unit pressure. Then the blood pressure for each heartbeat can be obtained by accumulating the Delta EBP. Invasive and noninvasive blood pressure values of six participants were measured simultaneously to evaluate the method. Results The average of the correlation coefficients between the invasive mean arterial pressure (MAP) and the KDT for six participants was -0.91. The average of the correlation coefficients between the invasive MAP and the estimated mean blood pressure (EBP) was 0.92. The mean difference between EBP and MAP was 0.51 mmHg, and the SD was 2.65 mmHg. The mean blood pressure estimated by the KDT is consistent with the invasive MAP. Conclusion The beat-to-beat blood pressure estimated by KDT provides an accurate estimate of MAP in the preliminary experiments and represents a potential acceptable alternative to invasive blood pressure monitoring during laboratory studies. Blood Press Monit 17:35-41 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [21] Increasing sleep duration to lower beat-to-beat blood pressure: a pilot study
    Haack, Monika
    Serrador, Jorge
    Cohen, Daniel
    Simpson, Norah
    Meier-Ewert, Hans
    Mullington, Janet M.
    JOURNAL OF SLEEP RESEARCH, 2013, 22 (03) : 295 - 304
  • [22] Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification
    Farzam, Ramin
    Azad, Mohammad Hasan
    Moghaddam, Hamid Abrishami
    Forouzanfar, Mohamad
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (02) : 619 - 629
  • [23] Increased Beat-to-Beat Blood Pressure Variability Is Associated With Impaired Cognitive Function
    Asmuje, Nur Fazidah
    Mat, Sumaiyah
    Goh, Choon Hian
    Myint, Phyo Kyaw
    Tan, Maw Pin
    AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (12) : 998 - 1005
  • [24] Beat-to-beat Systolic as Well as Diastolic Blood Pressure Variability is High in Atrial Fibrillation
    Olbers, Joakim
    Gille, Adam
    Ostergren, Jan
    Ljungman, Petter
    Rosenqvist, Marten
    Witt, Nils
    CIRCULATION, 2015, 132
  • [25] Augmented resting beat-to-beat blood pressure variability in patients with chronic kidney disease
    Sabino-Carvalho, Jeann L.
    Jeong, Jinhee
    Sprick, Justin
    Dacosta, Dana
    Nardone, Massimo
    Park, Jeanie
    CLINICAL AUTONOMIC RESEARCH, 2023, 33 (06) : 705 - 714
  • [26] Augmented resting beat-to-beat blood pressure variability in patients with chronic kidney disease
    Jeann L. Sabino-Carvalho
    Jinhee Jeong
    Justin Sprick
    Dana DaCosta
    Massimo Nardone
    Jeanie Park
    Clinical Autonomic Research, 2023, 33 : 705 - 714
  • [27] Interaction between cardiac beat-to-beat interval changes and systolic blood pressure changes
    Emma J. Bowers
    Alan Murray
    Clinical Autonomic Research, 2004, 14 : 92 - 98
  • [28] Interaction between cardiac beat-to-beat interval changes an systolic blood pressure changes
    Bowers, EJ
    Murray, A
    CLINICAL AUTONOMIC RESEARCH, 2004, 14 (02) : 92 - 98
  • [29] High beat-to-beat blood pressure variability in atrial fibrillation compared to sinus rhythm
    Olbers, Joakim
    Gille, Adam
    Ljungman, Petter
    Rosenqvist, Marten
    Ostergren, Jan
    Witt, Nils
    BLOOD PRESSURE, 2018, 27 (05) : 249 - 255
  • [30] Continuous Noninvasive Blood Pressure Monitoring of Beat-By-Beat Blood Pressure and Heart Rate Using Caretaker Compared With Invasive Arterial Catheter in the Intensive Care Unit
    Kwon, Younghoon
    Stafford, Patrick L.
    Enfield, Kyle
    Mazimba, Sula
    Baruch, Martin C.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (07) : 2012 - 2021