Comparison of Two Cooling and Dehumidifying Methods for a Semi-Closed Organic Tomato Greenhouse

被引:3
|
作者
Vallieres, M. [1 ]
de Halleux, D. [1 ]
Dorais, M. [2 ]
Bouzid, S. [3 ]
机构
[1] Univ Laval, Quebec City, PQ G1K 7P4, Canada
[2] Agr & Agri Food Canada, Quebec City, PQ G1V 0A6, Canada
[3] Jardins Nat, New Richmond, PQ G0C 2B0, Canada
来源
INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013 | 2014年 / 1037卷
关键词
carbon dioxide (CO2); geothermal energy; water curtain; fan coil; temperature; humidity; northern greenhouse;
D O I
10.17660/ActaHortic.2014.1037.78
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Two non-traditional methods of cooling and dehumidifying (C/D) were compared in a semi-closed greenhouse using cold water withdrawals from a saturated water table in order to 1) maintain the greenhouse semi-closed under high solar radiation, 2) evaluate the impact of both systems on temperature on relative air humidity (RH) and on vapor pressure deficit (VPD), 3) increase carbon dioxide levels (CO2) by limiting air external exchanges, and 4) reduce the CO2 consumption. The first studied method was a cold water fan coil system where greenhouse air was cooled through a coil on which the water vapour was condensed. The second method was a cold water curtain installed above the canopy, forcing warm humid air to condense on its surface, thus generating a free convection air movement within the greenhouse. These two heat exchanger methods were compared with the traditional natural ventilation C/D technique. The cooling capacities of both systems varied between 125 and 600 W m(-2). Under sunny summer days, higher than 838 W m(-2) for each system, the water curtain, the fan coil system and the traditional method were able to maintain set 24 h temperature (21.2, 21.2 and 21.9 degrees C), and RH (82.0, 82.4, and 77.5%) corresponding to acceptable VPD levels (0.5, 0.5 and 0.6) in the greenhouse. By maintaining closed-roofs, the water curtain and the fan coil technology maintained higher maximum levels of CO2 (1,046 and 992 mu mol mol(-1)) in the greenhouses compared to the traditional method (550 mu mol mol(-1)). During sunny days, the water curtain and the fan coil demonstrated higher maximum daily temperatures (26.6 and 29.6 degrees C), while cooler minimum temperatures during the night (18.1 and 15.8 degrees C) were observed resulting in a similar 24 h mean temperature. Compared to the water curtain, the fan coil system had the advantage of requiring low maintenance with a reduced fungal disease risk. When comparing the CO2 injection strategies, it was observed that the greenhouse using the fan coil technology injected up to 20% less than the traditional method.
引用
收藏
页码:611 / 616
页数:6
相关论文
共 50 条
  • [31] Comparison of predicted and measured oxygen levels in a semi-closed underwater breathing apparatus
    Nuckols, ML
    Finlayson, WS
    Newville, B
    Gavin, WA
    OCEANS 2001 MTS/IEEE: AN OCEAN ODYSSEY, VOLS 1-4, CONFERENCE PROCEEDINGS, 2001, : 1725 - 1730
  • [32] Comparison of organic and inorganic substrates in greenhouse tomato production
    Ingram, David M.
    Fain, Glenn B.
    Gilliam, Charles H.
    Boyer, Cheryl R.
    Hudson, Peter M.
    Crouse, K. Kieth
    HORTSCIENCE, 2007, 42 (04) : 989 - 989
  • [33] Development of a Cucumber Transpiration Model Based on a Simplified Penman-Monteith Model in a Semi-closed Greenhouse
    Rho, Hyungmin
    Jo, Jung Su
    Sim, Ha Seon
    Moon, Yu Hyun
    Woo, Ui Jeong
    Kim, Sung Kyeom
    HORTSCIENCE, 2023, 58 (10) : 1208 - 1216
  • [34] Energy utilization assessment of a semi-closed greenhouse using data-driven model predictive control
    Mahmood, Farhat
    Govindan, Rajesh
    Bermak, Amine
    Yang, David
    Khadra, Carol
    Al-Ansari, Tareq
    JOURNAL OF CLEANER PRODUCTION, 2021, 324
  • [35] Using Artificial Neural Networks to Predict the Climate in a Greenhouse: First Simulation Results on a Semi-Closed System
    Miranda, L.
    Schuch, I.
    Dannehl, D.
    Rocksch, T.
    Salazar, R.
    Schmidt, U.
    II INTERNATIONAL SYMPOSIUM ON HORTICULTURE IN EUROPE, 2015, 1099 : 137 - 144
  • [36] The increasing influence of oyster farming on sedimentary organic matter in a semi-closed subtropical bay
    Xie, Lei
    Yang, Bin
    Xu, Jie
    Lu, Dongliang
    Zhu, Wenjuan
    Cui, Dandan
    Huang, Haifang
    Zhou, Jiaodi
    Kang, Zhenjun
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 951
  • [37] The fate of nitrogen compounds and heavy metals in studied semi-closed organic paddy fields
    Su, Ming-Chien
    Kao, Nien-Hsin
    DESALINATION AND WATER TREATMENT, 2012, 46 (1-3) : 149 - 159
  • [38] Influence analysis of space configuration on cooling load of a large semi-closed atrium in hot and humid region
    Xu, Fei
    Li, Chunying
    Tang, Haida
    BUILDING AND ENVIRONMENT, 2022, 225
  • [39] Altered Plant Structure and Greater Yield of Cucumber Grown at Elevated CO2 in a Semi-Closed Greenhouse
    Luomala, E. -M.
    Sarkka, L.
    Kaukoranta, T.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON HIGH TECHNOLOGY FOR GREENHOUSE SYSTEM MANAGEMENT, VOLS 1 AND 2, 2008, (801): : 1339 - 1345
  • [40] STUDY OF VARIOUS COOLING METHODS AND THEIR EFFECT ON MICROCLIMATE AND TRANSPIRATION OF A GREENHOUSE TOMATO CROP
    BOULARD, T
    BAILLE, A
    LEGALL, F
    AGRONOMIE, 1991, 11 (07): : 543 - 553