Comparison of Two Cooling and Dehumidifying Methods for a Semi-Closed Organic Tomato Greenhouse

被引:3
|
作者
Vallieres, M. [1 ]
de Halleux, D. [1 ]
Dorais, M. [2 ]
Bouzid, S. [3 ]
机构
[1] Univ Laval, Quebec City, PQ G1K 7P4, Canada
[2] Agr & Agri Food Canada, Quebec City, PQ G1V 0A6, Canada
[3] Jardins Nat, New Richmond, PQ G0C 2B0, Canada
来源
INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013 | 2014年 / 1037卷
关键词
carbon dioxide (CO2); geothermal energy; water curtain; fan coil; temperature; humidity; northern greenhouse;
D O I
10.17660/ActaHortic.2014.1037.78
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Two non-traditional methods of cooling and dehumidifying (C/D) were compared in a semi-closed greenhouse using cold water withdrawals from a saturated water table in order to 1) maintain the greenhouse semi-closed under high solar radiation, 2) evaluate the impact of both systems on temperature on relative air humidity (RH) and on vapor pressure deficit (VPD), 3) increase carbon dioxide levels (CO2) by limiting air external exchanges, and 4) reduce the CO2 consumption. The first studied method was a cold water fan coil system where greenhouse air was cooled through a coil on which the water vapour was condensed. The second method was a cold water curtain installed above the canopy, forcing warm humid air to condense on its surface, thus generating a free convection air movement within the greenhouse. These two heat exchanger methods were compared with the traditional natural ventilation C/D technique. The cooling capacities of both systems varied between 125 and 600 W m(-2). Under sunny summer days, higher than 838 W m(-2) for each system, the water curtain, the fan coil system and the traditional method were able to maintain set 24 h temperature (21.2, 21.2 and 21.9 degrees C), and RH (82.0, 82.4, and 77.5%) corresponding to acceptable VPD levels (0.5, 0.5 and 0.6) in the greenhouse. By maintaining closed-roofs, the water curtain and the fan coil technology maintained higher maximum levels of CO2 (1,046 and 992 mu mol mol(-1)) in the greenhouses compared to the traditional method (550 mu mol mol(-1)). During sunny days, the water curtain and the fan coil demonstrated higher maximum daily temperatures (26.6 and 29.6 degrees C), while cooler minimum temperatures during the night (18.1 and 15.8 degrees C) were observed resulting in a similar 24 h mean temperature. Compared to the water curtain, the fan coil system had the advantage of requiring low maintenance with a reduced fungal disease risk. When comparing the CO2 injection strategies, it was observed that the greenhouse using the fan coil technology injected up to 20% less than the traditional method.
引用
收藏
页码:611 / 616
页数:6
相关论文
共 50 条
  • [21] Deep Reinforcement Learning Based Automatic Control in Semi-Closed Greenhouse Systems
    Ajagekar, Akshay
    You, Fengqi
    IFAC PAPERSONLINE, 2022, 55 (07): : 406 - 411
  • [22] COMPARISON OF LACK AND BAIN SEMI-CLOSED CIRCUITS IN SPONTANEOUS RESPIRATION
    NOTT, M
    WALTERS, F
    NORMAN, J
    BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (05) : 512 - 512
  • [23] Split root fertigation enhances cucumber yield in both an open and a semi-closed greenhouse
    Jokinen, Kari
    Sarkka, Liisa E.
    Nakkila, Juha
    Tahvonen, Risto
    SCIENTIA HORTICULTURAE, 2011, 130 (04) : 808 - 814
  • [24] Vertical microclimate heterogeneity and dew formation in semi-closed and naturally ventilated tomato greenhouses
    Jerszurki, Daniela
    Saadon, Tal
    Zhen, Jingbo
    Agam, Nurit
    Tas, Eran
    Rachmilevitch, Shimon
    Lazarovitch, Naftali
    SCIENTIA HORTICULTURAE, 2021, 288
  • [25] Optimization analysis of the motor cooling method in semi-closed single screw refrigeration compressor
    Wang, Z. L.
    Shen, Y. F.
    Wang, Z. B.
    Wang, J.
    10TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, 2017, 232
  • [26] Tomato yield in a closed greenhouse and comparison with simulated yields in closed and conventional greenhouses
    de Gelder, A
    Heuvelink, E
    Opdam, JJG
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SUSTAINABLE GREENHOUSE SYSTEMS, VOLS 1 AND 2, 2005, (691): : 549 - 552
  • [27] In Vitro Comparison of a Closed and Semi-closed Leaflet Design for Adult and Pediatric Transcatheter Heart Valves
    Breitenstein-Attach, Alexander
    Steitz, Marvin
    Sun, Xiaolin
    Hao, Yimeng
    Kiekenap, Jonathan
    Emeis, Jasper
    Tuladhar, Sugat Ratna
    Berger, Felix
    Schmitt, Boris
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (08) : 2051 - 2064
  • [28] A Prospective Randomized Comparison Between an Open Hemorrhoidectomy and a Semi-Closed (Semi-Open) Hemorrhoidectomy
    Noboru Mikuni
    Masatoshi Oya
    Junji Komatsu
    Tetsuo Yamana
    Surgery Today, 2002, 32 : 40 - 47
  • [29] A prospective randomized comparison between an open hemorrhoidectomy and a semi-closed (semi-open) hemorrhoidectomy
    Mikuni, N
    Oya, M
    Komatsu, J
    Yamana, T
    SURGERY TODAY, 2002, 32 (01) : 40 - 47
  • [30] THERMODYNAMIC COMPARISON OF SEMI-CLOSED AND OPEN-LOOP GAS-TURBINE ENGINE AIR COOLING SYSTEM EFFECTIVENESS.
    Manushin, E.A.
    Soviet Aeronautics (English translation of Izvestiya VUZ, Aviatsionnaya Tekhnika), 1981, 24 (01): : 15 - 19