The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study

被引:141
作者
Allum, Simon Rupert [1 ]
Tomlinson, Rachel Anne [2 ]
Joshi, Rajendra [3 ]
机构
[1] Dent Implant Clin, Darlington, Durham, England
[2] Univ Sheffield, Sheffield, S Yorkshire, England
[3] Charles Clifford Dent Hosp, Sheffield, S Yorkshire, England
关键词
dental; design; diameter; failure; fatigue; fracture; implants; mini; overload;
D O I
10.1111/j.1600-0501.2007.01395.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: While caution in the use of small-diameter (<= 3.5 mm) implants has been advocated in view of an increased risk of fatigue fracture under clinical loading conditions, a variety of implant designs with diameters < 3 mm are currently offered in the market for reconstructions including fixed restorations. There is an absence of reported laboratory studies and randomized-controlled clinical trials to demonstrate clinical efficacy for implant designs with small diameters. This laboratory study aimed to provide comparative data on the mechanical performance of a number of narrow commercially marketed implants. Materials and methods: Implants of varying designs were investigated under a standardized test set-up similar to that recommended for standardized ISO laboratory testing. Implant assemblies were mounted in acrylic blocks supporting laboratory cast crowns and subjected to 30 degrees off-axis loading on an LRX Tensometer. Continuous output data were collected using Nexygen software. Results: Load/displacement curves demonstrated good grouping of samples for each design with elastic deformation up to a point of failure approximating the maximum load value for each sample. The maximum loads for Straumann (control) implants were 989 N (+/- 107 N) for the 4.1 mm RN design, and 619 N (+/- 50 N) for the 3.3 mm RN implant (an implant known to have a risk of fracture in clinical use). Values for mini implants were recorded as 261 N (+/- 31 N) for the HiTec 2.4 mm implant, 237 N (+/- 37 N) for the Osteocare 2.8 mm mini and 147 N (+/- 25 N) for the Osteocare mini design. Other implant designs were also tested. Conclusions: The diameters of the commercially available implants tested demonstrated a major impact on their ability to withstand load, with those below 3 mm diameter yielding results significantly below a value representing a risk of fracture in clinical practice. The results therefore advocate caution when considering the applicability of implants <= 3 mm diameter. Standardized fatigue testing is recommended for all commercially available implants.
引用
收藏
页码:553 / 559
页数:7
相关论文
共 39 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] [Anonymous], 2003, 14801 ISO
  • [3] Balkin B E, 2001, J Oral Implantol, V27, P32, DOI 10.1563/1548-1336(2001)027<0032:MIIWTA>2.3.CO
  • [4] 2
  • [5] Barber H D, 1994, Compendium, V15, P1392
  • [6] A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years
    Berglundh, T
    Persson, L
    Klinge, B
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 : 197 - 212
  • [7] Brägger U, 1999, PROCEEDINGS OF THE 3RD EUROPEAN WORKSHOP ON PERIODONTOLOGY: IMPLANT DENTISTRY, P304
  • [8] Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
  • [9] Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants
    Buser, D
    MericskeStern, R
    Bernard, JP
    Behneke, A
    Behneke, N
    Hirt, HP
    Belser, UC
    Lang, NP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) : 161 - 172
  • [10] Force transmission of one- and two-piece morse-taper oral implants:: a nonlinear finite element analysis
    Çehreli, MC
    Akça, K
    Iplikçioglu, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 481 - 489