High sensitivity flow injection analysis of urea using composite electropolymerized polypyrrole-polyion complex film

被引:24
|
作者
Osaka, T [1 ]
Komaba, S
Fujino, Y
Matsuda, T
Satoh, I
机构
[1] Waseda Univ, Sch Sci & Engn, Dept Appl Chem, Tokyo 1698555, Japan
[2] Waseda Univ, Kagami Mem Lab Mat Sci & Technol, Tokyo 1698555, Japan
[3] Kanagawa Inst Technol, Fac Engn, Dept Appl Chem, Atsugi, Kanagawa 2430292, Japan
关键词
D O I
10.1149/1.1391652
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A highly sensitive and rapid flow injection system for urea analysis was constructed with a composite film of electropolymerized inactive polypyrrole (PPy) and a polyion complex incorporating urease. This system shows a sensitivity of 120 mV decade(-1) and a lifetime of more than 80 assays. The origin of the high sensitivity of this system is attributed to an additional potential response of inactive PPy to ammonia or ammonium ion superimposed on the response to pH change. By injecting a concentrated buffer solution immediately after the sample injection, this system is capable of assaying more than 15 samples per hour. (C) 1999 The Electrochemical Society. S0013-4651(98)05-073-3. All rights reserved.
引用
收藏
页码:615 / 619
页数:5
相关论文
共 50 条
  • [21] Enhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection
    Zhang, JZ
    ANALYTICAL SCIENCES, 2006, 22 (01) : 57 - 60
  • [22] Enhanced Sensitivity in Flow Injection Analysis Using a Long Pathlength Liquid Waveguide Capillary Flow Cell for Spectrophotometric Detection
    Jia-Zhong Zhang
    Analytical Sciences, 2006, 22 : 57 - 60
  • [23] FLOW-INJECTION ANALYSIS FOR HYDROGEN-PEROXIDE USING A TITANIUM(IV)-PORPHYRIN COMPLEX
    MATSUBARA, C
    NAKAMICHI, N
    KAWAMOTO, N
    TAKAMURA, K
    BUNSEKI KAGAKU, 1993, 42 (06) : 363 - 367
  • [24] Electrocatalytic detection of Hg(II) using a platinum electrode modified with composite film of cobalt(II) phthalocyanine tetra-substituted with 1-(methoxymethyl)-benzotriazole groups and co-electropolymerized polypyrrole *
    Shoba, Siyabonga
    Mambanda, Allen
    Booysen, Irvin Noel
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2024, 19 (04):
  • [25] Flow injection analysis of carbofuran in foods using air stable lipid film based acetylcholinesterase biosensor
    Nikolelis, DP
    Simantiraki, MG
    Siontorou, CG
    Toth, K
    ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) : 169 - 177
  • [26] SOFTWARE FIACRE - BIOPROCESS MONITORING ON THE BASIS OF FLOW-INJECTION ANALYSIS USING SIMULTANEOUSLY A UREA OPTODE AND A GLUCOSE LUMINESCENCE SENSOR
    BUSCH, M
    HOBEL, W
    POLSTER, J
    JOURNAL OF BIOTECHNOLOGY, 1993, 31 (03) : 327 - 343
  • [27] FLOW-INJECTION POTENTIOMETRIC AND VOLTAMMETRIC STRIPPING ANALYSIS USING A DIALYSIS MEMBRANE COVERED MERCURY FILM ELECTRODE
    ALDSTADT, JH
    KING, DF
    DEWALD, HD
    ANALYST, 1994, 119 (08) : 1813 - 1818
  • [28] Determination of serum glucose using flow injection analysis and highly selective glucose sensor based on composite films
    Huang, Chuncui
    Wang, Qian
    Gu, Chuantao
    Shao, Hui Bo
    ELECTROCHIMICA ACTA, 2012, 65 : 90 - 96
  • [29] Flow injection analysis of ethambutol in synthetic urine using a graphite-polyurethane composite electrode as an amperometric detector
    Perantoni, Camila B.
    de Azevedo, Alessandra B. R.
    Vaz, Fernando A. S.
    de Oliveira, Marcone A. L.
    Matos, Renato C.
    Lowinsohn, Denise
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (10): : 1668 - 1673
  • [30] Determination of β-D-glucose using flow injection analysis and composite-type amperometric tubular biosensors
    Alvarez-Romero, GA
    Rojas-Hernández, A
    Morales-Pérez, A
    Ramírez-Silva, MT
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (09): : 1057 - 1065