A combined impedance and traveling wave based fault location method for multi-terminal transmission lines

被引:68
|
作者
Ngu, E. E. [1 ]
Ramar, K. [1 ]
机构
[1] Multimedia Univ Malaysia, Fac Engn, Cyberjaya 63100, Malaysia
关键词
Fault location; Impedance based; Multi-terminal line; Traveling wave based;
D O I
10.1016/j.ijepes.2011.08.020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new fault location method suitable for multi-terminal transmission lines that combines the advantages of both impedance and traveling wave based methods has been developed and presented in this paper. The proposed method first determines whether the fault is grounded or ungrounded by comparing the magnitude of the ground mode wavelet coefficients at the measurement end. Next, the impedance based method is used to identify the faulted half of the line in the case of two-terminal line and the faulted line section as well as the faulted half of the line section in the case of multi-terminal lines. Finally the fault location is determined by taking the time difference between the first two consecutive aerial modes of the current traveling waves observed at one end of the multi-terminal line. The proposed method has been tested on four- and five-terminal transmission lines with different types of faults, fault resistances and fault inception angles using ATP simulation. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1767 / 1775
页数:9
相关论文
共 50 条
  • [1] Traveling Wave Based Fault Location of Multi-terminal Transmission Lines
    Sawai, Suraj
    Pradhan, A. K.
    Naidu, O. D.
    2017 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2017,
  • [2] A novel fault location scheme for multi-terminal transmission lines based on principle of double-ended traveling wave
    Fan, Xinqiao
    Zhu, Yongli
    Dianwang Jishu/Power System Technology, 2013, 37 (01): : 261 - 269
  • [3] Combined Traveling Wave and Fuzzy Logic Based Fault Location in Multi-Terminal HVDC Systems
    Hossam-Eldini, Ahmed
    Lotfy, Ahmed
    Elgamal, Mohammed
    Ebeed, Mohammed
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [4] Fault location system for multi-terminal transmission lines
    Junior G.M.
    Rodrigues E.C.N.
    Senger E.C.
    Nakagomi R.M.
    Pellini E.L.
    Controle y Automacao, 2010, 21 (02): : 201 - 213
  • [5] Gabor transform-based fault location method for multi-terminal transmission lines
    Moravej, Zahra
    Movahhedneya, Masoud
    Pazoki, Mohammad
    MEASUREMENT, 2018, 125 : 667 - 679
  • [6] A novel fault location method for multi-terminal transmission lines based on composite analysis of time-frequency fault traveling waves
    Zeng, Jupeng
    Zeng, Xiangjun
    Bai, Hao
    Yu, Kun
    Xu, Min
    She, Xiaolong
    Liu, Feng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2025, 167
  • [7] Parameter fitting-based traveling wave fault location method for multi-terminal DC grids
    Liu, Le
    Xie, Fan
    Kang, Xiaoning
    Hao, Zhiguo
    Lekic, Aleksandra
    Popov, Marjan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2025, 164
  • [8] A multi-terminal traveling wave fault location method for active distribution network based on residual clustering
    Qiao, Jian
    Yin, Xianggen
    Wang, Yikai
    Xu, Wen
    Tan, Liming
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 131
  • [9] Fault Location Method for Seafloor Observation Network Based on Multi-terminal Traveling Wave Time Difference
    Zeng X.
    Mao Y.
    Deng F.
    Li Y.
    Dianwang Jishu/Power System Technology, 2019, 43 (09): : 3280 - 3287
  • [10] Fault location scheme for a multi-terminal transmission line based on current traveling waves
    Zhu Yongli
    Fan Xinqiao
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 53 : 367 - 374