A comparison of two airway aids for emergency use by unskilled personnel - The Combitube and laryngeal mask

被引:46
|
作者
Yardy, N [1 ]
Hancox, D [1 ]
Strang, T [1 ]
机构
[1] Manchester Royal Infirm, Dept Anaesthesia, Manchester M13 9WL, Lancs, England
关键词
equipment; airway; laryngeal mask; Combitube; complications; regurgitation; aspiration;
D O I
10.1046/j.1365-2044.1999.00651.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Many non-anaesthetists find airway control and intubation difficult. The laryngeal mask has been advocated for use by non-anaesthetists at cardiorespiratory arrests, whilst the Combitube is said to provide protection from aspiration. We wished to determine which device was easiest for unskilled staff to use. Staff not previously trained in airway support were briefly taught insertion of each device. Twenty-six ASA 1 or 2 adults, requiring muscle relaxation and tracheal intubation for surgery, were recruited to this randomised crossover study Both devices were inserted in random order and the time to successful ventilation of the lungs recorded. Both devices were successfully placed in 24/26 patients. The median times to insertion were 40 s and 45 s for the laryngeal mask and Combitube, respectively, with two failures, both with the Combitube (p > 0.05); these were due to faulty operator technique. The Combitube may be a suitable alternative to the laryngeal mask for use in resuscitation by unskilled staff.
引用
收藏
页码:181 / 183
页数:3
相关论文
共 50 条
  • [41] UNILATERAL HYPOGLOSSAL NERVE PARALYSIS FOLLOWING THE USE OF THE LARYNGEAL MASK AIRWAY
    NAGAI, K
    SAKURAMOTO, C
    GOTO, F
    ANAESTHESIA, 1994, 49 (07) : 603 - 604
  • [42] A randomized trial comparing two laryngeal mask airway insertion techniques
    Koay, CK
    Yoong, CS
    Kok, P
    ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (06) : 613 - 615
  • [43] Perioperative use of the laryngeal mask airway in cases of obesity
    Rindfleisch, F.
    Seebauer, L.
    Friederich, P.
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 2022, 63 : 5 - 16
  • [44] Chondronecrosis of the Larynx Following Use of the Laryngeal Mask Airway
    Beswick, Daniel M.
    Collins, Jeremy
    Nekhendzy, Vladimir
    Damrose, Edward J.
    LARYNGOSCOPE, 2015, 125 (04) : 946 - 949
  • [45] Lignocaine to aid the insertion of the laryngeal mask airway with thiopentone - A comparison between topical and intravenous administration
    Cook, TM
    Savell, CR
    Cox, CM
    ANAESTHESIA, 1996, 51 (08) : 787 - 790
  • [46] A comparison of postoperative sore throat after use of laryngeal mask airway and tracheal tube
    Mizutamari E.
    Yano T.
    Ushijima K.
    Ito A.
    Anraku S.
    Tanimoto H.
    Terasaki H.
    Journal of Anesthesia, 2004, 18 (3) : 151 - 157
  • [47] Ease of insertion of the laryngeal mask airway by inexperienced personnel when using an introducer
    Dingley, J
    Baynham, P
    Swart, M
    Vaughan, RS
    ANAESTHESIA, 1997, 52 (08) : 756 - 760
  • [48] Comparison of Laryngeal Mask Airway Seal Between Anesthesiologists and Individuals Without Previous Airway Experience
    Tannheimer, Markus
    Reinke, Martin
    Lechner, Raimund
    JOURNAL OF EMERGENCY MEDICINE, 2024, 66 (04) : e470 - e476
  • [49] Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients
    Keller, C
    Brimacombe, JR
    Keller, K
    Morris, R
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (02) : 286 - 287
  • [50] THE EFFECTS OF 2-PERCENT LIGNOCAINE GEL ON INCIDENCE OF RETCHING WITH THE USE OF THE LARYNGEAL MASK AIRWAY
    CHAN, ST
    THAM, CS
    ANAESTHESIA, 1995, 50 (03) : 257 - 258