Respiratory gating for 3-dimensional PET of the thorax:: Feasibility and initial results

被引:0
|
作者
Boucher, L [1 ]
Rodrigue, S [1 ]
Lecomte, R [1 ]
Bénard, F [1 ]
机构
[1] CHUS, Hop Fleurimont, Clin Res Ctr, Metab & Funct Imaging Ctr, Sherbrooke, PQ J1H 5N4, Canada
关键词
motion correction; respiratory gating; F-18-FDG; PET;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion may reduce the sensitivity of F-18-FDG PET for the detection of small pulmonary nodules close to the base of the lungs. This motion also interferes with attempts to use fused PET/CT images through software or combined PET/CT devices. This study was undertaken to assess the feasibility of respiratory gating for PET of the chest and the impact of respiratory motion on quantitative analysis. Methods: Ten healthy subjects were enrolled in this study. Three-dimensional studies were acquired with 8 gates per respiratory cycle on a commercial PET scanner with a temperature-sensitive respiratory gating device built in-house. All scans were obtained over 42 cm of body length with 3 bed positions of 10 min each after injection of F-18-FDG at 4.5 MBq/kg. The reconstructed images were assembled to produce gated whole-body volumes and maximum-intensity projections. The amplitude of respiratory motion of the kidneys (as a surrogate for diaphragmatic incursion) as well as the apex of the heart was measured in the coronal plane. Phantom studies were acquired to simulate the impact of respiratory motion on quantitative uptake measurements. Results: The respiratory gating device produced a consistent, reliable trigger signal. All acquisitions were successful and produced reconstructed volumes with excellent image quality. Mean+/-SD motion amplitude and maximal motion amplitude values were 6.7+/-3.0 and 11.9 mm for the heart, 12.0+/-3.7 and 18.8 mm for the right kidney, and 11.1+/-4.8 and 17.1 mm for the left kidney, respectively. In phantom studies, the standardized uptake value for a 1-mL lesion was underestimated by 30% and 48% for the average and maximal respiratory motion values, respectively. Conclusion: Respiratory gating of PET of the thorax and upper abdomen is a practical and feasible approach that may improve the detection of small pulmonary nodules. Further work is planned to assess prospectively the diagnostic accuracy of this new method.
引用
收藏
页码:214 / 219
页数:6
相关论文
共 20 条
  • [1] Image-navigated 3-dimensional late gadolinium enhancement cardiovascular magnetic resonance imaging: feasibility and initial clinical results
    Bratis, Konstantinos
    Henningsson, Markus
    Grigoratos, Chrysanthos
    Dell'Omodarme, Matteo
    Chasapides, Konstantinos
    Botnar, Rene
    Nagel, Eike
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [2] Dual cardiac–respiratory gated PET: implementation and results from a feasibility study
    Axel Martinez-Möller
    Darko Zikic
    René M. Botnar
    Ralph A. Bundschuh
    William Howe
    Sibylle I. Ziegler
    Nassir Navab
    Markus Schwaiger
    Stephan G. Nekolla
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1447 - 1454
  • [3] Dual cardiac-respiratory gated PET:: implementation and results from a feasibility study
    Martinez-Moeller, Axel
    Zikic, Darko
    Botnar, Rene M.
    Bundschuh, Ralph A.
    Howe, William
    Ziegler, Sibylle I.
    Navab, Nassir
    Schwaiger, Markus
    Nekolla, Stephan G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (09) : 1447 - 1454
  • [4] Prospective feasibility trial of radiotherapy target definition for head and neck cancer using 3-dimensional PET and CT imaging
    Scarfone, C
    Lavely, WC
    Cmelak, AJ
    Delbeke, D
    Martin, WH
    Billheimer, D
    Hallahan, DE
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (04) : 543 - 552
  • [5] Gated 18F-FDG PET/CT of the Lung Using a Respiratory Spirometric Gating Device: A Feasibility Study
    Jaudet, Cyril
    Filleron, Thomas
    Weyts, Kathleen
    Didierlaurent, David
    Vallot, Delphine
    Ouali, Mounia
    Zerdoud, Slimane
    Dierickx, O. Lawrence
    Caselles, Olivier
    Courbon, Frederic
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2019, 47 (03) : 227 - 232
  • [6] A 3-dimensional hemispherical brain phantom for compact dedicated brain PET scanners
    Akamatsu, G.
    Tashima, H.
    Iwao, Y.
    Wakizaka, H.
    Maeda, T.
    Yoshida, E.
    Yamaya, T.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (02):
  • [7] Imaging characteristics of a 3-dimensional GSO whole-body PET camera
    Surti, S
    Karp, JS
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (06) : 1040 - 1049
  • [8] Characterization of 3-Dimensional PET Systems for Accurate Quantification of Myocardial Blood Flow
    Renaud, Jennifer M.
    Yip, Kathy
    Guimond, Jean
    Trottier, Mikael
    Pibarot, Philippe
    Turcotte, Eric
    Maguire, Conor
    Lalonde, Lucille
    Gulenchyn, Karen
    Farncombe, Troy
    Wisenberg, Gerald
    Moody, Jonathan
    Lee, Benjamin
    Port, Steven C.
    Turkington, Timothy G.
    Beanlands, Rob S.
    deKemp, Robert A.
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (01) : 103 - 109
  • [9] Simultaneous PET and Multispectral 3-Dimensional Fluorescence Optical Tomography Imaging System
    Li, Changqing
    Yang, Yongfeng
    Mitchell, Gregory S.
    Cherry, Simon R.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (08) : 1268 - 1275
  • [10] Intraindividual comparison of image quality using retrospective and prospective respiratory gating for the acquisition of thin sliced four dimensional multidetector CT of the thorax in a porcine model
    Behzadi, Cyrus
    Groth, Michael
    Henes, Frank Oliver
    Schwarz, Dorothee
    Deibele, Andre
    Begemann, Philipp G. C.
    Adam, Gerhard
    Regier, Marc
    EXPERIMENTAL LUNG RESEARCH, 2015, 41 (09) : 489 - 498