Pulse oximetry screening for critical congenital heart disease: a comparative study of cohorts over 11 years

被引:7
|
作者
Banait, Nishant [1 ]
Ward-Platt, Martin [1 ]
Abu-Harb, Majd [2 ]
Wyllie, Jonathan [3 ]
Miller, Nicola [4 ]
Harigopal, Sundeep [1 ]
机构
[1] Newcastle Upon Tyne Hosp NHS Fdn Trust, NICU, Newcastle Upon Tyne, Tyne & Wear, England
[2] NICU, Sunderland Royal Hosp, Sunderland, Tyne & Wear, England
[3] James Cook Univ Hosp, Middlesbrough, Cleveland, England
[4] Publ Hlth England North East, Natl Congenital Anomaly & Rare Dis Registrat Serv, Newcastle Upon Tyne, Tyne & Wear, England
关键词
Congenital heart disease (CHD); critical congenital heart disease (CCHD); pulse oximetry screening (POS); newborn screening; oxygen saturation; NEWBORN-INFANTS; DEFECTS; DIAGNOSIS; MALFORMATIONS;
D O I
10.1080/14767058.2018.1538348
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: Pulse oximetry (POS) has been proposed as a screening tool for CCHD in newborn. The aim was to identify the effect of POS on the rate of diagnosis after discharge and survival to one year in cases with CCHD. Material and Methods: All cases of CCHD from three tertiary level hospitals in the Northern region of UK between 1st January 2001 and 31st December 2011 were identified from the Northern Congenital Abnormality Survey (NorCAS). A retrospective cohort study comparing screened and unscreened population for CCHD was undertaken. The main outcome was post discharge diagnosis rate and mortality at one year between the cohorts. Results: Total number of births during the 11 years was 138,176. A total of 147 cases had CCHD, 59 diagnosed postnatally. Five and eight cases were diagnosed after discharge in the screened and the unscreened cohort respectively. The rate of post-discharge diagnosis in the screened population was 7/100,000 and 13/100,000 in the unscreened population with a relative risk of 0.52 (CI 0.2 to 1.42). Mortality at one year in postnatally diagnosed cases was five and one in the screened and unscreened cohorts respectively. Conclusion: With good antenatal detection rates, POS did not have a statistically significant impact in identifying cases of CCHD, when added to the present screening process of antenatal ultrasound and postnatal examination. The same conclusion cannot be made for regions with lower antenatal detection rates; perhaps it may be more appropriate to consider pulse oximetry as a screening tool for hypoxemia of any cause. Brief rationale This is the first study evaluating the contemporaneous post-discharge diagnosis rate between screened and unscreened populations. The rate of post-discharge diagnosis was 7/100,000 in the screened and 13/100,000 in the unscreened populations. However, this did not achieve statistical significance and in a setting with high antenatal diagnosis a very large study would be required to demonstrate efficacy of POS.
引用
收藏
页码:2064 / 2068
页数:5
相关论文
共 50 条
  • [1] Critical Congenital Heart Disease Screening Using Pulse Oximetry
    Frank, Lowell H.
    Bradshaw, Elizabeth
    Beekman, Robert
    Mahle, William T.
    Martin, Gerard R.
    JOURNAL OF PEDIATRICS, 2013, 162 (03) : 445 - 453
  • [2] Pulse oximetry screening of neonates for critical congenital heart disease
    Fritz, M.
    Fritsch, P.
    Foramitti, M.
    Simma, B.
    MONATSSCHRIFT KINDERHEILKUNDE, 2014, 162 (07) : 638 - 643
  • [3] Newborn Pulse Oximetry Screening to Detect Critical Congenital Heart Disease
    Studer, Matthew A.
    Smith, Ashley E.
    Lustik, Michael B.
    Carr, Michael R.
    JOURNAL OF PEDIATRICS, 2014, 164 (03) : 505 - +
  • [4] Pulse Oximetry Screening of Critical Congenital Heart Disease
    Ansary, Althaf
    INDIAN PEDIATRICS, 2015, 52 (07) : 626 - 626
  • [5] Pulse oximetry screening of congenital heart disease
    Serrano Madrid, M. L.
    Cardiel Valiente, L.
    Romero Gil, R.
    Pena Busto, A.
    BOLETIN DE PEDIATRIA, 2020, 60 (254): : 158 - 163
  • [6] Critical congenital heart disease screening with a pulse oximetry in neonates
    Hamilcikan, Sahin
    Can, Emrah
    JOURNAL OF PERINATAL MEDICINE, 2018, 46 (02) : 203 - 207
  • [7] Neonatal pulse oximetry screening improves detecting of critical congenital heart disease
    Ma Xiao-jing
    Huang Guo-ying
    CHINESE MEDICAL JOURNAL, 2013, 126 (14) : 2736 - 2740
  • [8] Pulse oximetry screening in newborns to enhance detection of critical congenital heart disease
    Narvey, Michael
    Wong, Kenny K.
    Fournier, Anne
    PAEDIATRICS & CHILD HEALTH, 2017, 22 (08) : 494 - 498
  • [9] Pulse Oximetry Screening for Critical Congenital Heart Disease: Bringing Evidence Into Practice
    Amsbaugh, Sarah
    Scott, Shannon D.
    Foss, Karen
    JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES, 2015, 30 (04): : 591 - 597
  • [10] Use of Pulse Oximetry Pulsatility Index Screening for Critical Congenital Heart Disease
    Rasmussen, Maynard
    Suttner, Denise
    Poeltler, Debra
    Katheria, Anup C.
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e545 - e549