A Non-Invasive Method for Condition Monitoring of Induction Motors Operating Under Arbitrary Loading Conditions

被引:13
作者
Irfan, Muhammad [1 ]
Saad, Nordin [1 ]
Ibrahim, Rosdiazli [1 ]
Asirvadam, Vijanth S. [1 ]
Magzoub, Muawia [1 ]
Hung, N. T. [1 ]
机构
[1] Univ Teknol PETRONAS, Dept Elect & Elect Engn, Bander Seri Iskander 31750, Perak, Malaysia
关键词
Condition monitoring; Fault diagnosis; Bearings; Signal processing; Instantaneous power analysis; FAULT-DIAGNOSIS; VIBRATION; SYSTEM;
D O I
10.1007/s13369-015-1996-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The literature review presents the various kinds of existing condition monitoring methods and highlights the need for an economical, intelligent fault diagnosis system for the motors that are being used in variable load applications. The motor current signature analysis (MCSA) has been used widely in previous research work for fault detection of the motor at full-load conditions. However, MCSA cannot detect faults under low-load conditions of the motor. This paper proposes the instantaneous power analysis (IPA) method for the bearing fault detection at various loading conditions of the motor. The experimental results indicate that IPA has more capability to detect faults under low-load conditions as compared to MCSA. Also, it has been shown that IPA carries an additional characteristic vibration frequency component which provides an extra piece of information that can be utilized in a reliable intelligent condition monitoring system. The proposed method has been validated through experiments at five different loading conditions of the motor.
引用
收藏
页码:3463 / 3471
页数:9
相关论文
共 40 条
  • [1] A Simple Real-Time Fault Signature Monitoring Tool for Motor-Drive-Embedded Fault Diagnosis Systems
    Akin, Bilal
    Choi, Seungdeog
    Orguner, Umut
    Toliyat, Hamid A.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) : 1990 - 2001
  • [2] [Anonymous], THESIS
  • [3] High Frequency Resolution Techniques for Rotor Fault Detection of Induction Machines
    Bellini, Alberto
    Yazidi, Arnine
    Filippetti, Fiorenzo
    Rossi, Claudio
    Capolino, Gerard-Andre
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) : 4200 - 4209
  • [4] Induction motor asymmetrical faults detection using advanced signal processing techniques
    Benbouzid, MEH
    Nejjari, H
    Beguenane, R
    Vieira, M
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (02) : 147 - 152
  • [5] Models for bearing damage detection in induction motors using stator current monitoring
    Bloedt, Martin
    Granjon, Pierre
    Raison, Bertrand
    Rostaing, Gilles
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (04) : 1813 - 1822
  • [6] OPERATIONAL PERFORMANCE OF GENERATOR CONDITION MONITORS - COMPARISON OF HEATED AND UNHEATED ION CHAMBERS
    BRAUN, JM
    BROWN, G
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (02) : 344 - 349
  • [7] Implementation of a Fault-Diagnosis Algorithm for Induction Machines Based on Advanced Digital-Signal-Processing Techniques
    Choi, Seungdeog
    Akin, Bilal
    Rahimian, Mina M.
    Toliyat, Hamid A.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (03) : 937 - 948
  • [8] Condition-based monitoring system for rolling element bearing using a generic multi-layer perceptron
    de Almeida, Luis F.
    Bizarria, Jose W. P.
    Bizarria, Francisco C. P.
    Mathias, Mauro H.
    [J]. JOURNAL OF VIBRATION AND CONTROL, 2015, 21 (16) : 3456 - 3464
  • [9] Stator Fault Diagnostics in Squirrel Cage Three-Phase Induction Motor Drives Using the Instantaneous Active and Reactive Power Signature Analyses
    Drif, M'hamed
    Marques Cardoso, Antonio J.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2014, 10 (02) : 1348 - 1360
  • [10] Elmaleeh M.A.A., 2010, International Conference on Intelligent and Advanced Syst, P1, DOI [10.1109/ICIAS.2010.5716110, DOI 10.1109/ICIAS.2010.5716110]