Tubing Erosion of an Inflatable Penile Prosthesis Long after Implantation

被引:5
|
作者
Morales, Alvaro [1 ]
机构
[1] Queens Univ, Dept Urol, Kingston, ON K7M 6R4, Canada
来源
SEXUAL MEDICINE | 2014年 / 2卷 / 02期
关键词
Inflatable Penile Prosthesis; Complications; Erosion; Tubal Erosion; COMPLICATIONS; RELIABILITY; EXPERIENCE; RESERVOIR;
D O I
10.1002/sm2.30
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction. Erosion through skin of connecting tubing of an inflatable penile prosthesis (IPP) has not been previously reported. Aim. The aim of this study was to present a case of tubing erosion, review the pertinent literature, and discuss the possible causes and management options, including preservation of the device and its components. Methods. A 42-year-old male failing to respond to medical treatment for erectile dysfunction underwent insertion of anAMS700 IPP in 1986. Six years later, a revision was necessary because of a leak in the right cylinder and 4 years after, the pump was replaced. Fourteen years after the original implant, he presented with a portion of the tube connecting the pump to the right cylinder eroding through the skin. There was no infection. The skin area involved was resected and the original pump and tubing were buried in a new scrotal pocket after thorough irrigation. Results. The IPP remained in place, allowing vaginal penetration and without infection for another 11 years. Three years later, it was de-functionalized, converted into a fixed volume device. It eventually was replaced 25 years after originally implanted with a semirigid prosthesis because it did not provide sufficient rigidity and because of concerns about the presence of "screws" detected during pelvic imaging. Conclusions. Mechanical failures in the early IPP models, as illustrated in this case, were expected. However, the long survival of the device is remarkable. Erosion of the connecting tubing through the skin is unique and, under exceptional circumstances, may be managed conservatively without replacing components of the IPP. Clinicians unfamiliar with procedures involving inflatable devices need to be aware of "foreign bodies" visible in radiological examinations in men who have had revisions of an IPP.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 50 条
  • [31] Inflatable Penile Prosthesis: Considerations in Revision Surgery
    Wintner, Anton
    Lentz, Aaron C.
    CURRENT UROLOGY REPORTS, 2019, 20 (04)
  • [32] Inflatable Penile Prosthesis: Considerations in Revision Surgery
    Anton Wintner
    Aaron C. Lentz
    Current Urology Reports, 2019, 20
  • [33] Inflatable penile prosthesis implantation into scarred corporal bodies: timing may decrease postoperative problems
    Hebert, Kristi L.
    Yafi, Faysal A.
    Wilson, Steve
    BJU INTERNATIONAL, 2020, 125 (01) : 168 - 172
  • [34] Long-term mechanical reliability of AMS 700CX™/CXM inflatable penile prosthesis
    Dhar, Nivedita Bhatta
    Angermeier, Kenneth W.
    Montague, Drogo K.
    JOURNAL OF UROLOGY, 2006, 176 (06): : 2599 - 2601
  • [35] Patient and partner outcome of inflatable and semi-rigid penile prosthesis in a single institution
    Bozkurt, Ibrahim Halil
    Arslan, Burak
    Yonguc, Tarik
    Kozacioglu, Zafer
    Degirmenci, Tansu
    Gunlusoy, Bulent
    Minareci, Suleyman
    INTERNATIONAL BRAZ J UROL, 2015, 41 (03): : 535 - 541
  • [36] A Guide for Inflatable Penile Prosthesis Reservoir Placement: Pertinent Anatomical Measurements of the Retropubic Space
    Henry, Gerard
    Hsaio, Wayland
    Karpman, Edward
    Bella, Anthony T.
    Carrion, Rafael
    Jones, Leroy
    Christine, Brian
    Eisenhart, Elizabeth
    Cleves, Mario A.
    Kramer, Andrew
    JOURNAL OF SEXUAL MEDICINE, 2014, 11 (01): : 273 - 278
  • [37] Efficacy and safety of malleable penile prosthesis compared to inflatable penile prosthesis in erectile dysfunction patients
    Satwikananda, Handaru
    Laksita, Tetuka Bagus
    Djatisoesanto, Wahjoe
    Soebadi, Doddy Moesbadianto
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2024, 96 (02) : 12353
  • [38] Association of the modified frailty index with adverse outcomes after penile prosthesis implantation
    Madbouly, Khaled
    AlHajeri, Dulaim
    Habous, Mohamad
    Binsaleh, Saleh
    AGING MALE, 2017, 20 (02): : 119 - 124
  • [39] Defining the incidence and management of postoperative scrotal hematoma after primary and complex three-piece inflatable penile prosthesis surgery
    Braun, Avery E.
    Swerdloff, Daniel
    Sudhakar, Architha
    Patel, Rutul D.
    Gross, Martin S.
    Simhan, Jay
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2025, 37 (01) : 82 - 86
  • [40] A Case Report of Large Bowel Obstruction in a Patient With an Inflatable Penile Prosthesis
    Atri, Elias
    Mallory, Chase
    Perez, Alejandra
    Wong, Vivian
    Cordon, Billy H.
    SEXUAL MEDICINE, 2021, 9 (04)