The Impact of Band Broadening on Molar-Mass Determination of Narrow-Distribution Polymer by Size-Exclusion Chromatography

被引:12
|
作者
Wolpers, Arne [1 ]
Russell, Gregory T. [2 ]
Vana, Philipp [1 ]
机构
[1] Univ Gottingen, Inst Phys Chem, D-37077 Gottingen, Germany
[2] Univ Canterbury, Dept Chem, Christchurch 1, New Zealand
关键词
band broadening; distribution reversible-deactivation radical polymerization; simulations; size-exclusion chromatography; MOLECULAR-WEIGHT DISTRIBUTIONS; PARAMETERS;
D O I
10.1002/mats.201100038
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A systematic study of the effects of band broadening (BB) in size-exclusion chromatography (SEC) on Poisson molar-mass distributions (MMDs) is carried out. Such distributions apply for polymer standards used for SEC calibration, and they are a good model for the MMD from any quasi-living polymerization, including reversible-deactivation radical polymerization (RDRP). BB is simulated using the exponentially modified Gaussian model, which is shown to work excellently for actual polymer standards. A series of simulations with this model revealed how BB parameter values affect number-average degree of polymerization and polydispersity index from SEC. It is shown that the skewness parameter is particularly important in these considerations. Many of the obtained trends echo ones from RDRP, suggesting that BB has been making a hitherto unsuspected-indeed uninvestigated-contribution to deviations from ideal behavior in such systems.
引用
收藏
页码:667 / 674
页数:8
相关论文
共 47 条
  • [41] Distribution analysis of ultra-high molecular mass poly(ethylene oxide) containing silica particles by size-exclusion chromatography with dual light- scattering and refractometric detection
    Porsch, B
    Welinder, A
    Körner, A
    Wittgren, B
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1068 (02) : 249 - 260
  • [42] DEVELOPMENT AND VALIDATION OF A SIZE EXCLUSION CHROMATOGRAPHY METHOD FOR DETERMINATION OF MOLECULAR MASSES AND MOLECULAR MASS-DISTRIBUTION IN LOW-MOLECULAR-WEIGHT HEPARIN
    KRISTENSEN, HI
    TROMBORG, EM
    NIELSEN, JR
    NIELSEN, JI
    JOHANSEN, KB
    OSTERGAARD, PB
    THROMBOSIS RESEARCH, 1991, 64 (02) : 131 - 141
  • [43] Determination of the Absolute Molar Mass of [Fe-S]-Containing Proteins Using Size Exclusion Chromatography-Multi-Angle Light Scattering (SEC-MALS)
    Velours, Christophe
    Zhou, Jingjing
    Zecchin, Paolo
    He, Nisha
    Salameh, Myriam
    Golinelli-Cohen, Marie-Pierre
    Golinelli-Pimpaneau, Beatrice
    BIOMOLECULES, 2022, 12 (02)
  • [44] Lanthanide polymer labels for multiplexed determination of biomarkers in human serum samples by means of size exclusion chromatography-inductively coupled plasma mass spectrometry
    Perez, Emma
    Bierla, Katarzyna
    Grindlay, Guillermo
    Szpunar, Joanna
    Mora, Juan
    Lobinski, Ryszard
    ANALYTICA CHIMICA ACTA, 2018, 1018 : 7 - 15
  • [45] Determination of thorium and light rare-earth elements in soil water and its high molecular mass organic fractions by inductively coupled plasma mass spectrometry and on-line-coupled size-exclusion chromatography
    Evelton A. Casartelli
    Norbert Miekeley
    Analytical and Bioanalytical Chemistry, 2003, 377 : 58 - 64
  • [46] DETERMINATION OF COPPER, ZINC AND ALUMINUM FROM DIETARY SOURCES IN THE FEMUR, BRAIN AND KIDNEY OF GUINEA-PIGS AND A STUDY OF SOME ELEMENTS IN IN-VIVO INTESTINAL DIGESTA BY SIZE-EXCLUSION CHROMATOGRAPHY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    OWEN, LMW
    CREWS, HM
    MASSEY, RC
    BISHOP, NJ
    ANALYST, 1995, 120 (03) : 705 - 712
  • [47] CHEMICAL MODIFICATION OF POLY(ETHER ETHER KETONE) FOR SIZE-EXCLUSION CHROMATOGRAPHY AT ROOM-TEMPERATURE .2. ON THE RELIABILITY OF THE DERIVATIZATION PROCEDURE FOR PEEK MOLECULAR-MASS DETERMINATION-APPLICATION TO PEEK-CARBON FIBER-COMPOSITE
    DAOUST, D
    GODARD, P
    DEVAUX, J
    LEGRAS, R
    STRAZIELLE, C
    POLYMER, 1994, 35 (25) : 5498 - 5503