Research on measurement method of LED Optical parameters

被引:0
|
作者
Liu Fang [1 ]
Zhao Yue-jin [1 ]
Wang Li-chang [2 ]
机构
[1] Beijing Inst Technol, Beijing 100081, Peoples R China
[2] Beijing Forestry Univ, Beijing 100083, Peoples R China
来源
INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2007: LASER, ULTRAVIOLET, AND TERAHERTZ TECHNOLOGY | 2008年 / 6622卷
关键词
LED; photometric; colorimetric; measurement;
D O I
10.1117/12.790917
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photometric and colorimetric parameters are important evaluations criterion of the performance of LED light sources. Photometric and colorimetric parameters of LED were measured using PMT spectroradiometer and CCD spectrometer respectively in this research, the result was discussed and the common method was improved. The result of experiment indicated that temperature drift of PMT spectroradiometer was compensated effectively by introducing reference standard light source; measurement accuracy of CCD spectrometer was improved significantly with standard LED. CCD spectrometer suitable for the industrial application for its rapid measuring speed, PMT spectroradiometer should be used in scientific research for its high measurement accuracy according to the experimental results.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Research on Meteorologic Temperature Measurement Method with High Precision
    Fan Changyuan
    Li Zhenfeng
    Guo Weibo
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION AND INSTRUMENTATION, VOL 4, 2008, : 1915 - 1918
  • [32] Telemetry Research of NO2 Concentration in the Night Based on LED and DOAS Method
    Yang Lei
    Li Ang
    Xie Pin-hua
    Hu Zhao-kun
    Liang Shuai-xi
    Zhang Ying-hua
    Huang Ye-yuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (05) : 1398 - 1405
  • [33] A LED-based phosphorimeter for measurement of microcirculatory oxygen pressure
    Guerci, Philippe
    Ince, Yasin
    Heeman, Paul
    Faber, Dirk
    Ergin, Bulent
    Ince, Can
    JOURNAL OF APPLIED PHYSIOLOGY, 2017, 122 (02) : 307 - 316
  • [34] Simulation and Experimental Study of Absolute Measurement Method for Optical Surface
    Meng Shi
    Liu Shijie
    Chen Lei
    Zhou You
    Bai Yunbo
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (05)
  • [35] A Measurement Method for Dispersion in Optical Fiber Communication with Long Distance
    Zheng, Xue-Zhao
    INTERNATIONAL JOURNAL OF FUTURE GENERATION COMMUNICATION AND NETWORKING, 2014, 7 (06): : 1 - 11
  • [36] Voltage-current characteristic of LED according to some optical and thermal parameters at pulsed high currents
    Ozuturk, Erdem
    OPTIK, 2015, 126 (21): : 3215 - 3217
  • [37] LED lamps evaluation of basic parameters
    Wisniewski, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (5A): : 166 - 168
  • [38] Research on the Influence of LED Temperature Shifts on Differential Optical Absorption Spectroscopy for Measuring NO2
    Ling Liu-yi
    Xie Pin-hua
    Qin Min
    Zheng Ni-na
    Ye Cong-lei
    Li Ang
    Hu Ren-zhi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (11) : 2886 - 2890
  • [39] Research Progress of Ultra-Precision Measurement of Optical Surfaces for Manufacturing
    Chen Shanyong
    Xue Shuai
    Xiong Yupeng
    Peng Xiaoqiang
    Dai Yifan
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (03)
  • [40] Research on Car Body Measurement Method Based on Body Repairing
    Cheng Jianzhong
    He Haotao
    Wu Xiaowei
    NEW TRENDS IN MECHANICAL ENGINEERING AND MATERIALS, 2013, 251 : 65 - 70