Four-corner arthrodesis using two headless compression screws

被引:1
|
作者
Iordache, Sorin Daniel [1 ,2 ,3 ]
Nam, Diane [1 ,4 ,5 ]
Peylan, Jacques [1 ,2 ,3 ]
Axelrod, Terry [1 ,4 ,5 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[2] Beilinson Med Ctr, Rabin Med Ctr, Dept Orthoped Surg, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[4] Sunnybrook Hlth Sci Ctr, Div Orthopaed Surg, Toronto, ON, Canada
[5] Univ Toronto, Toronto, ON, Canada
来源
ACTA ORTHOPAEDICA BELGICA | 2016年 / 82卷 / 02期
关键词
four-corner arthrodesis; headless compression screws; inter-observer agreement; wrist; SCAPHOLUNATE ADVANCED COLLAPSE; PROXIMAL ROW CARPECTOMY; CIRCULAR PLATE FIXATION; TRADITIONAL TECHNIQUES; SCAPHOID FRACTURES; UNION; WRIST; RELIABILITY; NONUNION; EXCISION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of motion, pain and complications were collected from the medical files. A total of 77 series of anteroposterior, oblique, and lateral x-rays were reviewed by three independent interpreters; consensus of at least two was required for the bones to be considered fused. Fusion was achieved in 24/27 wrists. Overall, inter-observer agreement in identifying radiographic bony fusion was fair (x = 0.41). At the critical timing, 86 (SD 68) days postoperatively, when the decision regarding fusion was made, inter-observer agreement was poor (x = 0.07). Our rates of fusion are consistent with reports in the literature. Radiographs performed at 3 months after four-corner arthrodesis are not reliable for the diagnosis of fusion.
引用
收藏
页码:332 / 338
页数:7
相关论文
共 50 条
  • [41] Proximal row carpectomy or scaphoid excision and four-corner arthrodesis for treatment of scapholunate advanced collapse arthritis
    Lin, James S.
    Moran, Steven L.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2025, 50 (01) : 68 - 75
  • [42] Proximal row carpectomy versus four-corner arthrodesis as a treatment for slac (scapholunate advanced collapse) wrist
    Vanhove, W.
    De Vil, J.
    Van Seymortier, P.
    Boone, B.
    Verdonk, R.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (02) : 118 - 125
  • [43] Clinical outcomes of proximal row carpectomy versus four-corner arthrodesis for post-traumatic wrist arthropathy: a systematic review
    Saltzman, B. M.
    Frank, J. M.
    Slikker, W.
    Fernandez, J. J.
    Cohen, M. S.
    Wysocki, R. W.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2015, 40 (05) : 450 - 457
  • [44] The rate of successful four-corner arthrodesis with a locking, dorsal circular polyether-ether-ketone (PEEK-Optima) plate
    Rhee, P. C.
    Shin, A. Y.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 767 - 773
  • [45] Salvage of advanced carpal collapse: proximal row carpectomy with pyrocarbon resurfacing of the capitate versus four-corner arthrodesis
    Ferrero, Matteo
    di Summa, Pietro G.
    Giacalone, Francesco
    Senesi, Letizia
    Sapino, Gianluca
    Battiston, Bruno
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (07) : 687 - 692
  • [46] Two Parallel Headless Compression Screws for Scaphoid Fractures: Radiographic Analysis and Preliminary Outcome
    Diprinzio, Eliseo V.
    Dieterich, James D.
    Walsh, Amanda L.
    Warburton, Andrew J.
    Chang, Andy L.
    Hausman, Michael R.
    Kim, Jaehon M.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023, 18 (08): : 1267 - 1274
  • [47] Variable Angle Locking Intercarpal Fusion System for Four-Corner Arthrodesis: Indications and Surgical Technique
    del Pino, Juan Gonzalez
    Campbell, Douglas
    Fischer, Thomas
    Vazquez, Fiesky Nunez
    Jupiter, Jesse B.
    Nagy, Ladislav
    JOURNAL OF WRIST SURGERY, 2012, 1 (01) : 73 - 78
  • [48] Four-Corner Arthrodesis with a Dorsal Locking PEEK Plate: A Retrospective Case Series
    Hayes, Emmitt
    Leswick, David A.
    Obaid, Haron
    Sauder, David A.
    JOURNAL OF WRIST SURGERY, 2023, 12 (03) : 225 - 231
  • [49] Four-corner arthrodesis using the 4Fusion® quadripodal shape memory staple: a long-term review
    Mevel, Gwenael
    De Geyer, Aymeric
    Kim, Warren
    Ebalard, Maud
    Ropars, Mickael
    Dreano, Thierry
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (04) : 387 - 392
  • [50] Two-, Three-, or Four-Corner Arthrodesis for Midcarpal Osteoarthritis: A Systematic Review and Meta-Analysis
    Hundepool, Caroline A.
    Duraku, Liron S.
    Quanjel, Thijs J. M.
    van Minnen, L. Paul
    Jansen, Miguel C.
    Zuidam, J. Michiel
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (01): : 93e1 - 93e11