Four-corner arthrodesis using two headless compression screws

被引:1
|
作者
Iordache, Sorin Daniel [1 ,2 ,3 ]
Nam, Diane [1 ,4 ,5 ]
Peylan, Jacques [1 ,2 ,3 ]
Axelrod, Terry [1 ,4 ,5 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[2] Beilinson Med Ctr, Rabin Med Ctr, Dept Orthoped Surg, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[4] Sunnybrook Hlth Sci Ctr, Div Orthopaed Surg, Toronto, ON, Canada
[5] Univ Toronto, Toronto, ON, Canada
来源
ACTA ORTHOPAEDICA BELGICA | 2016年 / 82卷 / 02期
关键词
four-corner arthrodesis; headless compression screws; inter-observer agreement; wrist; SCAPHOLUNATE ADVANCED COLLAPSE; PROXIMAL ROW CARPECTOMY; CIRCULAR PLATE FIXATION; TRADITIONAL TECHNIQUES; SCAPHOID FRACTURES; UNION; WRIST; RELIABILITY; NONUNION; EXCISION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of motion, pain and complications were collected from the medical files. A total of 77 series of anteroposterior, oblique, and lateral x-rays were reviewed by three independent interpreters; consensus of at least two was required for the bones to be considered fused. Fusion was achieved in 24/27 wrists. Overall, inter-observer agreement in identifying radiographic bony fusion was fair (x = 0.41). At the critical timing, 86 (SD 68) days postoperatively, when the decision regarding fusion was made, inter-observer agreement was poor (x = 0.07). Our rates of fusion are consistent with reports in the literature. Radiographs performed at 3 months after four-corner arthrodesis are not reliable for the diagnosis of fusion.
引用
收藏
页码:332 / 338
页数:7
相关论文
共 50 条
  • [31] Four-Corner Arthrodesis: Comparative Analysis of Open Technique Versus Percutaneous Technique with Arthroscopic Assistance
    Azocar, Camila
    Lecaros, Juan J.
    Bernal, Nazira
    Sanhueza, Miguel
    Liendo, Rodrigo
    Cifras, Jose L.
    JOURNAL OF WRIST SURGERY, 2022, 11 (02) : 127 - 133
  • [32] Treatment Outcomes of All Arthroscopic 4-Corner Arthrodesis Techniques With 2 Headless Screws
    Acar, Mehmet Ali
    Ozdemir, Ali
    Eravsar, Ebubekir
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (12): : 1278.e1 - 1278.e8
  • [33] FOUR-CORNER BONE ARTHRODESIS WITH DORSAL RECTANGULAR PLATE: SERIES AND PERSONAL TECHNIQUE
    Espinoza, D. P.
    Schertenleib, P.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (05) : 609 - 613
  • [34] Degenerative arthritis of the wrist: Proximal row carpectomy versus scaphoid excision and four-corner arthrodesis
    Cohen, MS
    Kozin, SH
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (01): : 94 - 104
  • [35] Decreased Complication Rate Using Partially Threaded Compared With Fully Threaded Compression Screws in 4 Corner Arthrodesis: A Retrospective Study
    Hanna, Tammam
    Smith, Nathan
    Akalonu, Chibuzo
    Simmons, Jack
    Nehete, Priyanka V.
    Dodson, Mark
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024, 19 (08): : 1214 - 1222
  • [36] Four-Corner Arthrodesis versus Proximal Row Carpectomy: Risk Factors and Complications Associated with Prolonged Postoperative Opioid Use
    Li, Neill Y.
    Kuczmarski, Alexander S.
    Hresko, Andrew M.
    Goodman, Avi D.
    Gil, Joseph A.
    Daniels, Alan H.
    JOURNAL OF HAND AND MICROSURGERY, 2022, 14 (02) : 163 - 169
  • [37] Comparison of Direct Surgical Costs for Proximal Row Carpectomy and Four-Corner Arthrodesis
    Kazmers, Nikolas H.
    Stephens, Andrew R.
    Presson, Angela P.
    Xu, Yizhe
    Feller, Ross J.
    Tyser, Andrew R.
    JOURNAL OF WRIST SURGERY, 2019, 8 (01) : 66 - 71
  • [38] Four-Corner Arthrodesis of the Wrist with Dorsal Circular Plate - a Retrospective Monocentric Study
    Zatrapa, T.
    Veigl, D.
    Pech, J.
    Landor, I.
    Simkova, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2017, 84 (03) : 189 - 195
  • [39] High Fusion Rates with Circular Plate Fixation for Four-corner Arthrodesis of the Wrist
    Bedford, Ben
    Yang, S. Steven
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 163 - 168
  • [40] Four-corner fusion: Comparing outcomes of conventional K-wire-, locking plate-, and retrograde headless compression screw fixations
    Erne, Holger C.
    Broer, P. Niclas
    Weiss, Fabian
    Loew, Steffen
    Cerny, Michael K.
    Schmauss, Daniel
    Ehrl, Denis C.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2019, 72 (06): : 909 - 917