Four-corner arthrodesis using two headless compression screws

被引:1
|
作者
Iordache, Sorin Daniel [1 ,2 ,3 ]
Nam, Diane [1 ,4 ,5 ]
Peylan, Jacques [1 ,2 ,3 ]
Axelrod, Terry [1 ,4 ,5 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[2] Beilinson Med Ctr, Rabin Med Ctr, Dept Orthoped Surg, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[4] Sunnybrook Hlth Sci Ctr, Div Orthopaed Surg, Toronto, ON, Canada
[5] Univ Toronto, Toronto, ON, Canada
来源
ACTA ORTHOPAEDICA BELGICA | 2016年 / 82卷 / 02期
关键词
four-corner arthrodesis; headless compression screws; inter-observer agreement; wrist; SCAPHOLUNATE ADVANCED COLLAPSE; PROXIMAL ROW CARPECTOMY; CIRCULAR PLATE FIXATION; TRADITIONAL TECHNIQUES; SCAPHOID FRACTURES; UNION; WRIST; RELIABILITY; NONUNION; EXCISION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of motion, pain and complications were collected from the medical files. A total of 77 series of anteroposterior, oblique, and lateral x-rays were reviewed by three independent interpreters; consensus of at least two was required for the bones to be considered fused. Fusion was achieved in 24/27 wrists. Overall, inter-observer agreement in identifying radiographic bony fusion was fair (x = 0.41). At the critical timing, 86 (SD 68) days postoperatively, when the decision regarding fusion was made, inter-observer agreement was poor (x = 0.07). Our rates of fusion are consistent with reports in the literature. Radiographs performed at 3 months after four-corner arthrodesis are not reliable for the diagnosis of fusion.
引用
收藏
页码:332 / 338
页数:7
相关论文
共 50 条
  • [21] Four-corner arthrodesis using a circular plate and distal radius bone grafting: A consecutive case series
    Merrell, Gregory A.
    McDermott, Erin M.
    Weiss, Arnold-Peter C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (05): : 635 - 642
  • [22] Results of four-corner arthrodesis using dorsal circular plate fixation
    Kendall, CB
    Brown, TR
    Millon, SJ
    Rudisill, LE
    Sanders, JL
    Tanner, SL
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (05): : 903 - 907
  • [23] Long-Term Outcome and Secondary Operations after Proximal Row Carpectomy or Four-Corner Arthrodesis
    Williams, John Barton
    Weiner, Hadley
    Tyser, Andrew R.
    JOURNAL OF WRIST SURGERY, 2018, 7 (01) : 51 - 56
  • [24] Capitolunate versus Four-Corner Arthrodesis for Midcarpal Arthrosis
    Kurucan, Etka
    Kasper, Alexis
    Sherman, Matthew
    Fletcher, Daniel
    Beredjiklian, Pedro
    Tosti, Rick
    JOURNAL OF WRIST SURGERY, 2024,
  • [25] Mechanical performance comparison of two surgical constructs for wrist four-corner arthrodesis via dorsal and radial approaches
    Faudot, Barthelemy
    Ballerini, Julien
    Ross, Mark
    Bellemere, Philippe
    de Monsabert, Benjamin Goislard
    Vigouroux, Laurent
    Milan, Jean-Louis
    CLINICAL BIOMECHANICS, 2021, 82 (82)
  • [26] Four-corner arthrodesis with a dorsal locking plate: 4-9-year follow-up
    Athlani, Lionel
    Sabau, Sophie
    Pauchard, Nicolas
    Dap, Francois
    Dautel, Gilles
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (07) : 673 - 678
  • [27] Effectiveness of Four-Corner Arthrodesis with Use of a Locked Dorsal Circular Plate
    Luegmair, Matthias
    Houvet, Patrick
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (10) : 2764 - 2770
  • [28] Comparative study between open and arthroscopic techniques for scaphoid excision and four-corner arthrodesis
    Shim, Jae
    Kim, Joo Whan
    Park, Min Jong
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (09) : 952 - 958
  • [29] Four-Corner Arthrodesis Concentrator of Nickel-Titanium Memory Alloy for Carpal Collapse: A Report on 18 Cases
    Xu, Yong-qing
    Qi, Bao-chuang
    Fan, Xin-yu
    Xu, Xiao-shan
    Lu, Sheng
    Ding, Jing
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (11): : 2246 - 2251
  • [30] Clinical and radiological outcomes of 40 cases of SLAC and SNAC wrist treated by four-corner arthrodesis with locking plate
    Rimokh, J.
    Benazech, B.
    Lebeau, N.
    Haddad, B.
    Moughabghab, M.
    David, E.
    HAND SURGERY & REHABILITATION, 2020, 39 (01): : 36 - 40