Frequent and severe hypoglycaemia detected with continuous glucose monitoring in older institutionalised patients with diabetes

被引:7
|
作者
Bouillet, Benjamin [1 ,2 ]
Tscherter, Pauline [1 ]
Vaillard, Laurence [3 ]
Nonciaux, Christine [4 ]
Hourdain, Philippe [5 ]
Ravier, Anne [6 ]
Rouland, Alexia [1 ,2 ]
Petit, Jean Michel [1 ,2 ]
Verges, Bruno [1 ,2 ]
Quilot, Emilienne [1 ,2 ]
机构
[1] Dijon Univ Hosp, Dept Endocrinol Diabet & Metab Disorders, Dijon, France
[2] Univ Burgundy, INSERM Unit, LNC UMR 1231, Dijon, France
[3] Dijon Univ Hosp, Hosp Champmaillot, Dijon, France
[4] EHPAD Port du Canal, Dijon, France
[5] EHPAD Combe St Victor, Neuilly Les Dijon, France
[6] EHPAD Fassoles, Talant, France
关键词
diabetes; hypoglycaemia; older adults; nursing homes; continuous glucose monitoring; freestyle libre pro; CARE; MANAGEMENT;
D O I
10.1093/ageing/afab128
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Little is known about the prevalence of hypoglycaemia in older people with diabetes. However, the HbA1c goal is >= 8% for institutionalised patients with treatments that can cause hypoglycaemia. Purpose: We aimed to assess the prevalence of hypoglycaemia with continuous glucose monitoring and to evaluate the link with HbA1C in older institutionalised patients with diabetes taking potentially hypoglycaemia-inducing drugs. Design: Prospective, multicentre study carried out in six geriatric care centres in the Cote d'Or region of France between January 2019 and July 2020. Settings, subjects and methods: A FreeStyle Libre Pro (R) (FSLP) was worn for up to 14 days in blinded mode in 42 patients taking at least one potentially hypoglycaemia-inducing antidiabetic drug. Results: Two hundred and forty-two hypoglycaemic events were detected in 79% (n= 33) of patients wearing the FSLP. One or more hypoglycaemic event was detected in 100% of patients with HbA1C< 7% and in 79% of patients with HbA1C >= 8% (P = 0.02). The time spent in hypoglycaemia was higher in patients with HbA1C< 7% than those with HbA1C >= 8% (P = 0.015). Time spent <54 mg/dl was detected in 45% of patients. Conclusions: We report a very high prevalence of hypoglycaemia, with a significant proportion of severe hypoglycaemia, in older institutionalised patients with diabetes taking potentially hypoglycaemia-inducing drugs. Having HbA1C< 7% exposes patients to a higher risk of hypoglycaemia, but this risk remains also high in patients with HbA1C >= 8%. In this population, continuous glucose monitoring could be considered an effective tool to detect hypoglycemia, which is associated with increased risk of cardiovascular events, falling, fractures, cognitive impairment and mortality.
引用
收藏
页码:2088 / 2093
页数:6
相关论文
共 50 条
  • [21] Continuous glucose monitoring: quality of hypoglycaemia detection
    Zijlstra, E.
    Heise, T.
    Nosek, L.
    Heinemann, L.
    Heckermann, S.
    DIABETES OBESITY & METABOLISM, 2013, 15 (02) : 130 - 135
  • [22] Patients' evaluation of nocturnal hypoglycaemia with GlucoDay continuous glucose monitoring in paediatric patients
    Meschi, Franco
    Bonfanti, Riccardo
    Rigamonti, Andrea
    Giulio, Frontino
    Battaglino, Roseila
    Viscardi, Matteo
    Poscia, Alessandro
    Chiumello, Giuseppe
    ACTA DIABETOLOGICA, 2010, 47 (04) : 295 - 300
  • [23] Continuous glucose monitoring in persons with type 2 diabetes not using insulin
    Cowart, Kevin
    Updike, Wendy H.
    Franks, Rachel
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (11) : 1049 - 1055
  • [24] The challenge of assessing impaired awareness of hypoglycaemia in diabetes in the era of continuous glucose monitoring: A narrative review of evidence and translation into clinical practice
    Berry, Simon A.
    Liarakos, Alexandros L.
    Koutroukas, Vaios
    Choudhary, Pratik
    Wilmot, Emma G.
    Iqbal, Ahmed
    DIABETES OBESITY & METABOLISM, 2025, 27 (05) : 2363 - 2376
  • [25] Frequency of biochemical hypoglycaemia in adults with Type 1 diabetes with and without impaired awareness of hypoglycaemia: no identifiable differences using continuous glucose monitoring
    Choudhary, P.
    Geddes, J.
    Freeman, J. V.
    Emery, C. J.
    Heller, S. R.
    Frier, B. M.
    DIABETIC MEDICINE, 2010, 27 (06) : 666 - 672
  • [26] Usability and Teachability of Continuous Glucose Monitoring Devices in Older Adults and Diabetes Educators: Task Analysis and Ease-of-Use Survey
    Psavko, Simon
    Katz, Noam
    Mirchi, Tina
    Green, Courtney R.
    JMIR HUMAN FACTORS, 2022, 9 (04):
  • [27] Influence of Dialysis on the Glucose Profile in Patients with Diabetes: Usefulness of Continuous Glucose Monitoring
    Chantrel, F.
    Sissoko, H.
    Kepenekian, L.
    Smagala, A.
    Meyer, L.
    Imhoff, O.
    Serb, L.
    Fleury, D.
    Dorey, F.
    Krummel, T.
    Le Floch, J. P.
    Kessler, L.
    HORMONE AND METABOLIC RESEARCH, 2014, 46 (11) : 810 - 813
  • [28] Oral glucose tolerance test and continuous glucose monitoring to assess diabetes development in cystic fibrosis patients
    Clemente Leon, Maria
    Bilbao Gasso, Laura
    Moreno-Galdo, Antonio
    Campos Martorrell, Ariadna
    Gartner Tizzano, Silvia
    Yeste Fernandez, Diego
    Carrascosa Lezcano, Antonio
    ENDOCRINOLOGIA DIABETES Y NUTRICION, 2018, 65 (01): : 45 - 51
  • [29] Cross-sectional association of metrics derived from continuous glucose monitoring with cognitive performance in older adults with type 2 diabetes
    Sugimoto, Taiki
    Tokuda, Haruhiko
    Miura, Hisayuki
    Kawashima, Shuji
    Ando, Takafumi
    Kuroda, Yujiro
    Matsumoto, Nanae
    Fujita, Kosuke
    Uchida, Kazuaki
    Kishino, Yoshinobu
    Sakurai, Takashi
    DIABETES OBESITY & METABOLISM, 2023, 25 (01) : 222 - 228
  • [30] Unrecognised hypoglycaemia in children and adolescents with type 1 diabetes using the continuous glucose monitoring system: Prevalence and contributors
    Wiltshire, Esko J.
    Newton, Kirsty
    McTavish, Lindsay
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2006, 42 (12) : 758 - 763