Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography

被引:111
|
作者
de Souza Neto, E. Pereira [1 ,2 ,3 ,4 ]
Grousson, S. [1 ]
Duflo, F. [1 ]
Ducreux, C. [5 ]
Joly, H. [5 ]
Convert, J. [1 ]
Mottolese, C. [6 ]
Dailler, F. [1 ]
Cannesson, M. [7 ]
机构
[1] Hosp Civils Lyon, Groupement Hosp Est, Hop Neurol Pierre Wertheimer, Serv Anesthesie Reanimat, F-69677 Bron, France
[2] Ecole Normale Super Lyon, CNRS, Phys Lab, F-69364 Lyon 07, France
[3] Hosp Reg, Sao Paulo, Brazil
[4] UNOESTE, Sao Paulo, Brazil
[5] Hosp Civils Lyon, Groupement Hosp Est, Hop Louis Pradel, Serv Cardiol C, F-69677 Bron, France
[6] Hosp Civils Lyon, Groupement Hosp Est, Hop Neurol Pierre Wertheimer, Serv Neurochirurg Infantile, F-69677 Bron, France
[7] Univ Calif Irvine, Dept Anesthesiol & Perioperat Care, Sch Med, Orange, CA 92668 USA
关键词
arterial pulse pressure; fluid responsiveness; haemodynamic; plethysmographic waveform; respiratory variations; PULSE PRESSURE VARIATION; PEDIATRIC ANIMAL-MODEL; DIFFERENT LOADING CONDITIONS; STROKE VOLUME VARIATION; WAVE-FORM AMPLITUDE; OF-THE-LITERATURE; RESPIRATORY VARIATIONS; ARTERIAL COMPLIANCE; OPERATING-ROOM; MONITOR;
D O I
10.1093/bja/aer090
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Dynamic variables are accurate predictors of fluid responsiveness in adults undergoing mechanical ventilation. They can be determined using respiratory variation in aortic flow peak velocity (Delta Vpeak), arterial pulse pressure [Delta PP and pulse pressure variation (PPV)], or plethysmographic waveform amplitude [Delta POP and pleth variability index (PVI)]. These indices have not been validated in children. We studied the ability of these variables to predict fluid responsiveness in mechanically ventilated children. Methods. All results are expressed as median [median absolute deviation (MAD)]. Thirty mechanically ventilated children were studied after undergoing general anaesthesia. Mechanical ventilation was maintained with a tidal volume of 10 ml kg(-1) of body weight. Delta PP, PPV, Delta POP, PVI, Delta Vpeak, and aortic velocity-time integral were recorded before and after volume expansion (VE). Patients were considered to be responders to VE when the aortic velocity-time integral increased more than 15% after VE. Results. VE induced significant changes in Delta PP [13 (MAD 4) to 9 (5)%], PPV [15 (5) to 9 (5)%], Delta POP [15 (10) to 10 (6)%], PVI [13 (6) to 8 (5)%], and Delta Vpeak [16 (9) to 8 (3)%] (P < 0.05 for all). Differences in Delta PP, Delta POP, PPV, and PVI did not reach statistical significance. Only Delta Vpeak was significantly different between responders (R) and non-responders (NR) to VE [22 (3) vs 7 (1)%, respectively; P < 0.001]. The threshold Delta Vpeak value of 10% allowed discrimination between R and NR. Conclusions. In this study, Delta Vpeak was the most appropriate variable to predict fluid responsiveness.
引用
收藏
页码:856 / 864
页数:9
相关论文
共 38 条
  • [31] Predicting Fluid Responsiveness in Critically Ill Patients by Using Combined End-Expiratory and End-Inspiratory Occlusions With Echocardiography
    Jozwiak, Mathieu
    Depret, Francois
    Teboul, Jean-Louis
    Alphonsine, Jean-Emmanuel
    Lai, Christopher
    Richard, Christian
    Monnet, Xavier
    CRITICAL CARE MEDICINE, 2017, 45 (11) : E1131 - E1138
  • [32] Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia
    Kavita G. Morparia
    Srijaya K. Reddy
    Laura J. Olivieri
    Michael C. Spaeder
    Jennifer J. Schuette
    Journal of Clinical Monitoring and Computing, 2018, 32 : 221 - 226
  • [33] Predicting fluid responsiveness in ICU patients: comparison of different parameters and cutoff limits using pulse power analysis assessment
    H Barrasa
    J Maynar
    S Castaño
    Y Poveda
    P Garcia Domelo
    A Tejero
    G Baziskueta
    A Quintano
    B Fernández Miret
    M Iturbe
    S Cabañes
    F Fonseca
    Critical Care, 19 (Suppl 1):
  • [34] The importance of sensor contacting force for predicting fluid responsiveness in children using respiratory variations in pulse oximetry plethysmographic waveform
    Jonghyun Park
    Seungman Yang
    Ji-Hyun Lee
    Jin-Tae Kim
    Hee-Soo Kim
    Hee Chan Kim
    Journal of Clinical Monitoring and Computing, 2019, 33 : 393 - 401
  • [35] The importance of sensor contacting force for predicting fluid responsiveness in children using respiratory variations in pulse oximetry plethysmographic waveform
    Park, Jonghyun
    Yang, Seungman
    Lee, Ji-Hyun
    Kim, Jin-Tae
    Kim, Hee-Soo
    Kim, Hee Chan
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (03) : 393 - 401
  • [36] Non-invasive measurement of digital plethysmographic variability index to predict fluid responsiveness in mechanically ventilated children: A systematic review and meta-analysis of diagnostic test accuracy studies
    Desgranges, Francois-Pierrick
    Bouvet, Lionel
    Neto, Edmundo Pereira de Souza
    Evain, Jean-Noel
    Terrisse, Hugo
    Joosten, Alexandre
    Desebbe, Olivier
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2023, 42 (03)
  • [37] Identification of volume parameters monitored with a noninvasive ultrasonic cardiac output monitor for predicting fluid responsiveness in children after congenital heart disease surgery
    Cheng, Yu-wei
    Xu, Feng
    Li, Jing
    MEDICINE, 2018, 97 (39)
  • [38] Dynamic Arterial Elastance as a Predictor of Intraoperative Fluid Responsiveness in Elderly Patient over 70 Years of Age Undergoing Spine Surgery in the Prone Position Under General Anesthesia: A Validation Study
    Oh, Eun Jung
    Cho, Eun Ah
    Jun, Joohyun
    Lee, Sung Hyun
    Lee, Seunghyeon
    Ahn, Jin Hee
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)