Flexible Screen-Printed Electrochemical Sensors Functionalized with Electrodeposited Copper for Nitrate Detection in Water

被引:39
|
作者
Inam, A. K. M. S. [1 ,2 ]
Angeli, Martina A. Costa [1 ]
Shkodra, Bajramshahe [1 ]
Douaki, Ali [1 ]
Avancini, Enrico [1 ]
Magagnin, Luca [3 ]
Petti, Luisa [1 ]
Lugli, Paolo [1 ]
机构
[1] Free Univ Bozen Bolzano, Fac Sci & Technol, I-39100 Bolzano, Italy
[2] Daffodil Int Univ, Dept Nutr & Food Engn, Dhaka 1207, Bangladesh
[3] Dept Chem Mat & Chem Engn Giulio Natta, I-20133 Milan, Italy
来源
ACS OMEGA | 2021年 / 6卷 / 49期
关键词
ELECTROCATALYTIC REDUCTION; RAPID DETECTION; REAL-TIME; NITRITE; PLATINUM; ARRAYS; NANOSTRUCTURES; NANOPARTICLES; MECHANISM; FACILE;
D O I
10.1021/acsomega.1c04296
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nitrate (NO3-) contamination is becoming a major concern due to the negative effects of an excessive NO3- presence in water which can have detrimental effects on human health. Sensitive, real-time, low-cost, and portable measurement systems able to detect extremely low concentrations of NO3- in water are thus becoming extremely important. In this work, we present a novel method to realize a low-cost and easy to fabricate amperometric sensor capable of detecting small concentrations of NO3- in real water samples. The novel fabrication technique combines printing of a silver (Ag) working electrode with subsequent modification of the electrode with electrodeposited copper (Cu) nanoclusters. The process was tuned in order to reach optimized sensor response, with a high catalytic activity toward electroreduction of NO3- - (sensitivity: 19.578 mu A/mM), as well as a low limit of detection (LOD: 0.207 nM or 0.012 mu g/L) and a good dynamic linear concentration range (0.05 to 5 mM or 31 to 310 mg/L). The sensors were tested against possible interference analytes (NO2-, Cl-, SO42-, HCO3-, CH3COO-, Fe2+,Fe3-, Mn2+, Na+, and Cu2+) yielding only negligible effects [maximum standard deviation (SD) was 3.9 mu A]. The proposed sensors were also used to detect NO 3 - in real samples, including tap and river water, through the standard addition method, and the results were compared with the outcomes of high-performance liquid chromatography (HPLC). Temperature stability (maximum SD 3.09 mu A), stability over time (maximum SD 3.69 mu A), reproducibility (maximum SD 3.20 mu A), and repeatability (maximum two-time useable) of this sensor were also investigated.
引用
收藏
页码:33523 / 33532
页数:10
相关论文
共 50 条
  • [41] Electrochemical and Optical Sensors for Real-Time Detection of Nitrate in Water
    Lal, Kartikay
    Jaywant, Swapna A.
    Arif, Khalid Mahmood
    SENSORS, 2023, 23 (16)
  • [42] Electrochemical Metallization Process on Screen-Printed Electrode for Creatinine Monitoring Application
    Khushaini, Muhammad Asif A.
    Azeman, Nur Hidayah
    Teh, Chin-Hoong
    Daik, Rusli
    Ismail, Ahmad Ghadafi
    Majlis, Burhanuddin Yeop
    Salleh, Muhammad Mat
    Adnan, Wan Ahmad Hafiz Wan Md
    Aziz, Tg Hasnan Tg Abdul
    Bakar, Ahmad Ashrif A.
    Zain, Ahmad Rifqi Md
    IEEE SENSORS JOURNAL, 2022, 22 (10) : 9268 - 9275
  • [43] Electrochemical Behavior of Some Cinchona Alkaloids Using Screen-Printed Electrodes
    Caruso, Tonino
    Palombi, Laura
    SENSORS, 2025, 25 (07)
  • [44] Graphene-Gold Nanostructures Hybrid Composites Screen-Printed Electrode for the Sensitive Electrochemical Detection of Vancomycin
    Blidar, Adrian
    Feier, Bogdan
    Pusta, Alexandra
    Dragan, Ana-Maria
    Cristea, Cecilia
    COATINGS, 2019, 9 (10)
  • [45] Electrochemical Detection of Epinephrine Based on a Screen-printed Electrode Modified with NiO-ERGO Nanocomposite Film
    Gunes, Ozlem
    Sarilmaz, Adem
    Bas, Salih Zeki
    Ozmen, Mustafa
    Ozel, Faruk
    Ersoz, Mustafa
    ELECTROANALYSIS, 2021, 33 (12) : 2460 - 2468
  • [46] Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes
    Munteanu, Florentina-Daniela
    Titoiu, Ana Maria
    Marty, Jean-Louis
    Vasilescu, Alina
    SENSORS, 2018, 18 (03):
  • [47] Fabrication and Characterization of Flexible and Miniaturized Humidity Sensors Using Screen-Printed TiO2 Nanoparticles as Sensitive Layer
    Dubourg, Georges
    Segkos, Apostolos
    Katona, Jaroslav
    Radovic, Marko
    Savic, Slavica
    Niarchos, Georgios
    Tsamis, Christos
    Crnojevic-Bengin, Vesna
    SENSORS, 2017, 17 (08):
  • [48] Utilising copper screen-printed electrodes (CuSPE) for the electroanalytical sensing of sulfide
    Thakur, Bhawana
    Bernalte, Elena
    Smith, Jamie P.
    Foster, Christopher W.
    Linton, Patricia E.
    Sawant, Shilpa N.
    Banks, Craig E.
    ANALYST, 2016, 141 (04) : 1233 - 1238
  • [49] Manganese oxide based screen-printed sensor for xenoestrogens detection
    Gurban, Ana-Maria
    Burtan, Diana
    Rotariu, Lucian
    Bala, Camelia
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 273 - 280
  • [50] Development of a molecularly imprinted electrochemical sensor for erlotinib detection using a modified screen-printed carbon electrode
    Ahmed, Saif Ali
    Roushani, Mahmoud
    Karazan, Zahra Mirzaei
    MICROCHIMICA ACTA, 2025, 192 (03)