Contemporary Application of Cardiovascular Hemodynamics: Transcatheter Aortic Valve Interventions

被引:2
作者
Jilaihawi, Hasan [1 ]
Kar, Saibal [1 ]
Doctor, Niraj [1 ]
Fontana, Gregory [1 ]
Makkar, Raj [1 ]
机构
[1] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
关键词
Transcatheter aortic valve implantation; Percutaneous aortic valve replacement; Edwards Sapien valve; Medtronic CoreValve; Hemodynamics; Aortic stenosis; PROSTHESIS-PATIENT MISMATCH; CORONARY INTERVENTION; SEPTAL HYPERTROPHY; IMPLANTATION; STENOSIS; REPLACEMENT; SYSTEM; MANAGEMENT; GRADIENTS; PRESSURE;
D O I
10.1016/j.ccl.2011.01.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Over the past two decades, echocardiography has replaced cardiac catheterization for aortic valvular hemodynamic assessment. In recent years, however, there has been a rapid evolution of transcatheter aortic valve technology and, with its refinement, there has been the increasing recognition of the value of transcatheter hemodynamic assessment in complementing the information provided by contemporary echocardiography. With an emphasis on transcatheter hemodynamics, this article reviews the symbiotic application of these assessment modalities pertaining to contemporary transcatheter aortic valve implantation.
引用
收藏
页码:211 / +
页数:13
相关论文
共 40 条
[1]   Unexpected Complications of Transapical Aortic Valve Implantation [J].
Al-Attar, Nawwar ;
Ghodbane, Walid ;
Himbert, Dominique ;
Rau, Cederic ;
Raffoul, Richard ;
Messika-Zeitoun, David ;
Brochet, Eric ;
Vahanian, Alec ;
Nataf, Patrick .
ANNALS OF THORACIC SURGERY, 2009, 88 (01) :90-94
[2]   Echo/Doppler Evaluation of Hemodynamics After Aortic Valve Replacement Principles of Interrogation and Evaluation of High Gradients [J].
Bach, David S. .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (03) :296-304
[3]  
Bae Jang-Ho, 2006, J Invasive Cardiol, V18, P359
[4]   Percutaneous Aortic Valve Implants Under Sedation: Our Initial Experience [J].
Behan, Miles ;
Haworth, Peter ;
Hutchinson, Nevil ;
Trivedi, Uday ;
Laborde, Jean-Claude ;
Hildick-Smith, David .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (07) :1012-1015
[5]  
BENDOR I, 2010, VASCULAR DIS MANAGEM, V7, pE1
[6]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.05.007]
[7]   CONTINUOUS WAVE DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF PROSTHETIC VALVE GRADIENTS - A SIMULTANEOUS DOPPLER-CATHETER CORRELATIVE STUDY [J].
BURSTOW, DJ ;
NISHIMURA, RA ;
BAILEY, KR ;
REEDER, GS ;
HOLMES, DR ;
SEWARD, JB ;
TAJIK, AJ .
CIRCULATION, 1989, 80 (03) :504-514
[8]   CHANGES IN ARTERIAL-PRESSURE DURING LEFT HEART PULLBACK IN PATIENTS WITH AORTIC-STENOSIS - SIGN OF SEVERE AORTIC-STENOSIS [J].
CARABELLO, BA ;
BARRY, WH ;
GROSSMAN, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1979, 44 (03) :424-427
[9]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[10]   CONTINUOUS-WAVE DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF SEVERITY OF CALCIFIC AORTIC-STENOSIS - A SIMULTANEOUS DOPPLER-CATHETER CORRELATIVE STUDY IN 100 ADULT PATIENTS [J].
CURRIE, PJ ;
SEWARD, JB ;
REEDER, GS ;
VLIETSTRA, RE ;
BRESNAHAN, DR ;
BRESNAHAN, JF ;
SMITH, HC ;
HAGLER, DJ ;
TAJIK, AJ .
CIRCULATION, 1985, 71 (06) :1162-1169