The association between 24-h blood pressure patterns and left ventricular mechanics

被引:20
|
作者
Tadic, Marijana [1 ,5 ]
Cuspidi, Cesare [2 ,3 ]
Majstorovic, Anka [1 ]
Pencic, Biljana [1 ]
Mancia, Giuseppe [4 ]
Bombelli, Michele [4 ]
Grassi, Guido [4 ]
Kocijancic, Vesna [1 ]
Djukic, Vladimir [1 ]
Celic, Vera [1 ]
机构
[1] Univ Clin Hosp Ctr Dr Dragisa Misovic Dedinje, Dept Cardiol, Belgrade, Serbia
[2] Univ Milano Bicocca, Clin Res Unit, Meda, Italy
[3] Ist Auxol Italiano IRCCS, Meda, Italy
[4] Univ Milano Bicocca, Dept Med & Surg, Clin Med, Milan, Italy
[5] Charite Univ Med Berlin, Campus Virchow Klinikum, Dept Internal Med & Cardiol, Augustenburgerpl 1, D-13353 Berlin, Germany
关键词
extreme dipping; hypertension; left ventricle; nondipping; reverse dipping; strain; DIPPING PATTERN; LONGITUDINAL STRAIN; AMERICAN-SOCIETY; TASK-FORCE; ECHOCARDIOGRAPHY; RECOMMENDATIONS; QUANTIFICATION; HYPERTENSION; REVERSE; RISK;
D O I
10.1097/HJH.0000000000002241
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: We sought to investigate left ventricular (LV) mechanics in the recently diagnosed hypertensive patients with different 24-h blood pressure (BP) patterns (dipping, nondipping, extreme dipping and reverse dipping). Methods: The current cross-sectional study included 209 hypertensive patients who underwent 24-h ambulatory BP monitoring and comprehensive two-dimensional echocardiographic examination including multilayer strain analysis. Results: There was no difference in 24-h and daytime BP values between four groups. Night-time BP significantly and gradually increased from extreme dippers, across dippers and nondippers, to reverse dippers. LV global longitudinal and circumferential strains were greater in dippers and extreme dippers than in nondippers and reverse dippers. This was also found for endocardial and epicardial LV longitudinal and circumferential strains. Multivariate logistic regression analysis demonstrated that nondipping and reverse dipping patterns were associated with reduced LV longitudinal strain [odds ratio (OR) 1.71 (95% confidence interval (CI): 1.10-5.61) and OR 2.50 (95% CI: 1.31-6.82), respectively] independently of age, sex, 24-h SBP, LV mass index and E/e. Only the reverse dipping BP pattern was independently of clinical and echocardiographic parameters related with reduced LV circumferential strain [OR 1.90 (95% CI: 1.10-4.80)]. Conclusion: Nondipping and reverse dipping BP patterns had stronger impact on LV mechanics compared with patients with dipping and extreme dipping BP patterns in hypertensive population. LV functional and mechanical remodeling deteriorated from extreme dippers and dippers, to nondippers and reverse dippers.
引用
收藏
页码:282 / 288
页数:7
相关论文
共 50 条
  • [1] The Association between Obesity, Blood Pressure Variability, and Right Ventricular Function and Mechanics in Hypertensive Patients
    Tadic, Marijana
    Cuspidi, Cesare
    Vukomanovic, Vladan
    Kocijancic, Vesna
    Celic, Vera
    Stanisavljevic, Dejana
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (08) : 802 - 811
  • [2] Automated Office Blood Pressure and 24-h Ambulatory Measurements are Equally Associated With Left Ventricular Mass Index
    Andreadis, Emmanuel A.
    Agaliotis, Gerasimos D.
    Angelopoulos, Epameinondas T.
    Tsakanikas, Athanasios P.
    Chaveles, Loannis A.
    Mousoulis, George P.
    AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (06) : 661 - 666
  • [3] The interaction between blood pressure variability, obesity, and left ventricular mechanics: findings from the hypertensive population
    Tadic, Marijana
    Cuspidi, Cesare
    Pencic, Biljana
    Andric, Anita
    Pavlovic, Sinisa U.
    Iracek, Olinka
    Celic, Vera
    JOURNAL OF HYPERTENSION, 2016, 34 (04) : 772 - 780
  • [4] Impact of age on the association between 24-h ambulatory blood pressure measurements and target organ damage
    Olesen, Thomas B.
    Pareek, Manan
    Stidsen, Jacob V.
    Blicher, Marie K.
    Rasmussen, Susanne
    Vishram-Nielsen, Julie K. K.
    Kjaer-Hansen, Kathrine
    Olsen, Michael H.
    JOURNAL OF HYPERTENSION, 2018, 36 (09) : 1895 - 1901
  • [5] The relationship of left ventricular outflow tract presystolic wave and 24-h ambulatory blood pressure measurements
    Demiroz, Onder
    Ozturkeri, Burak
    BLOOD PRESSURE MONITORING, 2022, 27 (06) : 378 - 383
  • [6] The Prognostic Effect of Circadian Blood Pressure Pattern on Long-Term Cardiovascular Outcome Is Independent of Left Ventricular Remodeling
    Tadic, Marijana
    Cuspidi, Cesare
    Celic, Vera
    Pencic, Biljana
    Mancia, Giuseppe
    Grassi, Guido
    Stankovic, Goran
    Ivanovic, Branislava
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [7] INFLUENCE OF THE CARDIOSELECTIVE BETA-BLOCKERS CELIPROLOL AND ATENOLOL ON 24-H BLOOD-PRESSURE AND LEFT-VENTRICULAR HYPERTROPHY
    WAMBACH, G
    GRIMM, U
    JACOB, R
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1994, 23 (04) : 167 - 169
  • [8] Association of longitudinal changes in 24-h blood pressure level and variability with cognitive decline
    Melgarejo, Jesus D.
    Vatcheva, Kristina P.
    Mejia-Arango, Silvia
    Charisis, Sokratis
    Patil, Dhrumil
    Mena, Luis J.
    Garcia, Antonio
    Alliey-Rodriguez, Ney
    Satizabal, Claudia L.
    Chavez, Carlos A.
    Gaona, Ciro
    Silva, Egle
    Mavarez, Rosa P.
    Lee, Joseph H.
    Terwilliger, Joseph D.
    Blangero, John
    Seshadri, Sudha
    Maestre, Gladys E.
    JOURNAL OF HYPERTENSION, 2024, 42 (11) : 1985 - 1993
  • [9] Association Between Left Ventricular Mechanics and Heart Rate Variability in Untreated Hypertensive Patients
    Tadic, Marijana
    Cuspidi, Cesare
    Pencic, Biljana
    Pavlovic, Sinisa U.
    Ivanovic, Branislava
    Kocijancic, Vesna
    Celic, Vera
    JOURNAL OF CLINICAL HYPERTENSION, 2015, 17 (02) : 118 - 125
  • [10] Nondipping pattern on 24-h ambulatory blood pressure monitoring is associated with left ventricular hypertrophy in chronic kidney disease
    Jaques, David A.
    Mueller, Hajo
    Martinez, Chantal
    De Seigneux, Sophie
    Martin, Pierre-Yves
    Ponte, Belen
    Saudan, Patrick
    BLOOD PRESSURE MONITORING, 2018, 23 (05) : 244 - 252