Electric Field Behavior of Water Drop on Composite Insulator Surface under DC Stress

被引:0
|
作者
Challagondla, Naresh Kumar [1 ]
Schramm, Heinz-H [2 ]
机构
[1] Brandenburg Tech Univ Cottbus, LSEVH, Cottbus, Germany
[2] Elektrotech Verein ETV eV, Bezirksverein Berlin Brandenburg VDE, Berlin, Germany
关键词
Pollution; Energy transmission; DC; Composite insulators; Water drop; Electric field;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of this paper is to study the behavior of the electric field near a water drop on composite insulator surface under DC stress. The studies are performed using a simple structure of composite insulator with two sheds. Simulation software based on Maxwell equations is considered in the investigation of a water drop. Water drop is placed at different positions on the insulator shed. The electric field values while moving the water drop from the core of the insulator to the edge of the shed are observed. The electric field values under DC stress are measured using the DC conduction solver in the ANSYS MAXWELL software. It can be seen from the simulations that positions of water drop significantly affects the electric field. The contact angle between the insulator surface and water drop has an impact on the electric field. Therefore it is important to observe the simulation results to know the behavior of a contact angle on the electric field stress. For this purpose four different angles are considered in this study. It can be seen from the results that the contact angle considerably affects the electric field values.
引用
收藏
页码:336 / 339
页数:4
相关论文
共 50 条
  • [31] Deformation and breakup of water droplets containing polymer under a DC electric field
    Huang, Xin
    Luo, Xiaoming
    Han, Yunrui
    Li, Weidong
    Lai, Yuekun
    Teng, Lin
    AICHE JOURNAL, 2022, 68 (10)
  • [32] Distribution of surface electric field of water and water droplets landing and its influence on the insulator flashover characteristics
    Wu G.
    Shao M.
    Peng S.
    Yang K.
    Zhang X.
    Wu, Guangning (gnwu@home.swjtu.edu.cn), 1600, Science Press (43): : 557 - 566
  • [33] SURFACE ELECTRIC STRENGTH OF PROCESSED PRESSBOARD UNDER COMPOSITE AC AND DC AND CONVENTIONAL STRESSES
    RAGHUVEER, MR
    KOLACZKOWSKI, Z
    WEIFANG, J
    KUFFEL, E
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1990, 25 (02): : 341 - 350
  • [34] Fatigue behavior of piezoelectric ceramics under an applied electric field and stress
    Sakai, T
    Ogawa, S
    Kawamoto, H
    Yanagida, H
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1999, 107 (08) : 743 - 747
  • [35] Behavior near critical for a conducting drop in an electric field
    Dubash, Neville
    Mestel, A. Jonathan
    PHYSICS OF FLUIDS, 2007, 19 (07)
  • [36] Electric field and the charge distribution on the surface of an insulator in a vacuum
    V. K. Belyaev
    Technical Physics, 2005, 50 : 673 - 679
  • [37] Electric field and the charge distribution on the surface of an insulator in a vacuum
    Belyaev, VK
    TECHNICAL PHYSICS, 2005, 50 (06) : 673 - 679
  • [38] The Influence of Electric Field Distribution on Insulator Surface Flashover
    Liu, Lin
    Li, Xiaoang
    Zhang, Qiaogen
    Liang, Chengjun
    Ren, Haiyang
    Zhao, Junping
    Li, Zhibing
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 255 - 258
  • [39] Critical electric field strength for partial coalescence of droplets on oil-water interface under DC electric field
    Yang, Donghai
    Ghadiri, Mojtaba
    Sun, Yongxiang
    He, Limin
    Luo, Xiaoming
    Lu, Yuling
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 136 : 83 - 93
  • [40] Electric Field Computation of Water Droplets on a Model Insulator
    Sarang, Bhargavi
    Basappa, Prathap
    Lakdawala, Vishnu
    Shivaraj, Gayathri
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 377 - 381