Development and application of a multi-targeting reference plasmid as calibrator for analysis of five genetically modified soybean events

被引:21
作者
Pi, Liqun [1 ]
Li, Xiang [2 ]
Cao, Yiwei [1 ]
Wang, Canhua [1 ]
Pan, Liangwen [2 ]
Yang, Litao [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Life Sci & Biotechnol, Natl Ctr Mol Characterizat Genetically Modified O, Collaborat Innovat Ctr Biosafety GMOs, Shanghai 200240, Peoples R China
[2] Shanghai Entry Exit Inspect & Quarantine Bur Chin, Tech Ctr Anim Plant & Food Inspect & Quarantine, Shanghai 200135, Peoples R China
基金
中国国家自然科学基金;
关键词
Multiple targets plasmid molecule; Genetically modified soybean; Qualitative PCR; Quantitative real-time PCR; QUANTITATIVE PCR METHOD; MODIFIED ORGANISMS; MODIFIED MAIZE; QUANTIFICATION; ESTABLISHMENT; GMOS;
D O I
10.1007/s00216-015-8517-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reference materials are important in accurate analysis of genetically modified organism (GMO) contents in food/feeds, and development of novel reference plasmid is a new trend in the research of GMO reference materials. Herein, we constructed a novel multi-targeting plasmid, pSOY, which contained seven event-specific sequences of five GM soybeans (MON89788-5', A2704-12-3', A5547-127-3', DP356043-5', DP305423-3', A2704-12-5', and A5547-127-5') and sequence of soybean endogenous reference gene Lectin. We evaluated the specificity, limit of detection and quantification, and applicability of pSOY in both qualitative and quantitative PCR analyses. The limit of detection (LOD) was as low as 20 copies in qualitative PCR, and the limit of quantification (LOQ) in quantitative PCR was 10 copies. In quantitative real-time PCR analysis, the PCR efficiencies of all event-specific and Lectin assays were higher than 90 %, and the squared regression coefficients (R-2) were more than 0.999. The quantification bias varied from 0.21 % to 19.29 %, and the relative standard deviations were from 1.08 % to 9.84 % in simulated samples analysis. All the results demonstrated that the developed multi-targeting plasmid, pSOY, was a credible substitute of matrix reference materials, and could be used as a reliable reference calibrator in the identification and quantification of multiple GM soybean events.
引用
收藏
页码:2877 / 2886
页数:10
相关论文
共 23 条
[1]   Detection of genetically modified organisms in foods [J].
Ahmed, FE .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (05) :215-223
[2]  
Carter C.A., 2003, CHOICES, V18, P1
[3]   Toward metrological traceability for DNA fragment ratios in GM quantification. 3. Suitability of DNA calibrants studied with a MON 810 corn model [J].
Charels, Diana ;
Broeders, Sylvia ;
Corbisier, Philippe ;
Trapmann, Stefanie ;
Schimmel, Heinz ;
Emons, Hendrik .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (09) :3268-3274
[4]  
Ciabatti I, 2005, DEV BIOL BASEL, V126, P79
[5]  
Corbisier P, 2007, EC CERTIFICATION REP
[6]   First application of a microsphere-based immunoassay to the detection of genetically modified organisms (GMOs): Quantification of Cry1Ab protein in genetically modified maize [J].
Fantozzi, Anna ;
Ermolli, Monica ;
Marini, Massimiliano ;
Scotti, Domenico ;
Balla, Branko ;
Querci, Maddalena ;
Langrell, Stephen R. H. ;
Van den Eede, Guy .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (04) :1071-1076
[7]   Reliable detection and identification of genetically modified maize, soybean, and canola by multiplex PCR analysis [J].
James, D ;
Schmidt, AM ;
Wall, E ;
Green, M ;
Masri, S .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (20) :5829-5834
[8]   Genetically modified crops: Detection strategies and biosafety issues [J].
Kamle, Suchitra ;
Ali, Sher .
GENE, 2013, 522 (02) :123-132
[9]   GMO detection using a bioluminescent real time reporter (BART) of loop mediated isothermal amplification (LAMP) suitable for field use [J].
Kiddle, Guy ;
Hardinge, Patrick ;
Buttigieg, Neil ;
Gandelman, Olga ;
Pereira, Clint ;
McElgunn, Cathal J. ;
Rizzoli, Manuela ;
Jackson, Rebecca ;
Appleton, Nigel ;
Moore, Cathy ;
Tisi, Laurence C. ;
Murray, James A. H. .
BMC BIOTECHNOLOGY, 2012, 12
[10]  
Kuribara H, 2002, J AOAC INT, V85, P1077