The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population

被引:77
|
作者
Seibert, J. Anthony [1 ]
Morin, Richard L. [2 ]
机构
[1] Univ Calif Davis, Dept Radiol, Sacramento, CA 95817 USA
[2] Mayo Clin Jacksonville, Dept Radiol, Jacksonville, FL 32224 USA
关键词
Digital radiography; Digital radiography exposure index; Pediatric radiography radiation dose; Radiography exposure index standard; ACR dose index registry;
D O I
10.1007/s00247-010-1954-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The exposure index is currently a method by which digital radiography manufacturers provide feedback to the technologist regarding the estimated exposure on the detector, as a surrogate for image signal-to-noise ratio and an indirect indication of digital image quality. Unfortunately, there are as many exposure index values and methods as there are manufacturers, and in an environment with multiple vendors and a need to share data across institutions and dose registry databases, the situation is complicated. Fortunately, a new exposure index of digital X-ray imaging systems has been implemented. Developed concurrently by the International Electrotechnical Commission and the American Association of Physicists in Medicine in cooperation with digital radiography system manufacturers, the index has been implemented as an international standard. As explained, the exposure index does not indicate patient dose but rather a linearly proportional estimate of the incident radiation exposure to the detector. However, the use of the standardized exposure index and its associated target exposure index and deviation index values will likely lead to improved technologist performance in terms of uniformity and use of optimized radiographic techniques, leading to safer care of children needing radiographic examinations. Radiologists will benefit from standardized terminology, and institutions and clinics will be able to compare exposure index values with others through a national dose index registry database now under development. The Alliance for Radiation Safety in Pediatric Imaging, in its role as a benefactor of and advocate for the pediatric patient, is using the Image Gently campaign to disseminate information regarding the exposure index standard for digital radiography so that these benefits can be achieved in a rapid and effective manner.
引用
收藏
页码:573 / 581
页数:9
相关论文
共 50 条
  • [31] Image Gently Campaign Back to Basics Initiative: Ten Steps to Help Manage Radiation Dose in Pediatric Digital Radiography
    Don, Steven
    MacDougall, Robert
    Strauss, Keith
    Moore, Quentin T.
    Goske, Marilyn J.
    Cohen, Mervyn
    Herrmann, Tracy
    John, Susan D.
    Noble, Lauren
    Morrison, Greg
    Lehman, Lois
    Whiting, Bruce R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : W431 - W436
  • [32] Optimizing Imaging Quality and Radiation Dose by the Age-Dependent Setting of Tube Voltage in Pediatric Chest Digital Radiography
    Guo, Hui
    Liu, Wen-Ya
    He, Xiao-Ye
    Zhou, Xiao-Shan
    Zeng, Qun-Li
    Li, Bai-Yan
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (01) : 126 - 131
  • [33] Large dose reduction by optimization of multifrequency processing software in digital radiography at follow-up examinations of the pediatric femur
    Precht, Helle
    Gerke, Oke
    Rosendahl, Karen
    Tingberg, Anders
    Waaler, Dag
    PEDIATRIC RADIOLOGY, 2014, 44 (02) : 239 - 240
  • [34] Large dose reduction by optimization of multifrequency processing software in digital radiography at follow-up examinations of the pediatric femur
    Helle Precht
    Oke Gerke
    Karen Rosendahl
    Anders Tingberg
    Dag Waaler
    Pediatric Radiology, 2014, 44 : 239 - 240
  • [35] USE OF CLINICAL EXPOSURE INDEX AND DEVIATION INDEX BASED ON NATIONAL DIAGNOSTIC REFERENCE LEVEL AS DOSE-OPTIMIZATION TOOLS FOR GENERAL RADIOGRAPHY IN KOREA
    Park, Hyemin
    Yoon, Yongsu
    Kim, Jungmin
    Kim, Jungsu
    Jeong, Hoiwoun
    Tanaka, Nobukazu
    Morishita, Junji
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) : 439 - 451
  • [36] A Landmark Detection Approach Applied to Robust Estimation of the Exposure Index in Digital Radiography
    Irrera, P.
    Bloch, I.
    Delplanque, M.
    IRBM, 2017, 38 (01) : 42 - 55
  • [37] Image Quality Optimization vs. Patient Dose in Digital Thoracic Radiography
    Perez-Diaz, M.
    Ruiz-Gonzalez, Y.
    Machin-Linares, L.
    Ely-Andrade, M.
    Barros-Saito, J. C.
    Khoury, H. J.
    Ventosa-Almeida, J. C.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 353 - 356
  • [38] OPTIMIZATION OF FILTERING AND EXPOSURE PARAMETERS IN HAND-OPERATED DIGITAL LUMINESCENCE RADIOGRAPHY
    GROTE, R
    NAST, J
    ROSENTHAL, H
    CALLEJA, R
    VONFALKENHAUSEN, U
    RIEDER, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (06): : 564 - 569
  • [39] DIGITAL RADIOGRAPHY AS A TOOL FOR THE KINEMATIC ANALYSIS OF THE SHOULDER JOINT - A STUDY OF RADIATION-DOSE
    MICHIELS, I
    MOHR, W
    SCHILD, HH
    PAIER, KP
    GREVENSTEIN, J
    BIOMEDIZINISCHE TECHNIK, 1991, 36 (06): : 149 - 152
  • [40] Radiation Dose Reduction in Digital Plain Radiography of the Knee after Total Knee Arthroplasty
    Kloth, J. K.
    Tanner, M.
    Stiller, W.
    Burkholder, I.
    Kauczor, H. U.
    Ewerbeck, V.
    Weber, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (08): : 685 - 690