Quantitative analysis of 3D coronary modeling in 3D rotational X-ray imaging

被引:0
|
作者
Movassaghi, B [1 ]
Rasche, V [1 ]
Viergever, MA [1 ]
Niessen, W [1 ]
机构
[1] Philips Res Labs, D-22335 Hamburg, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the analysis of the accuracy of modeling approaches to coronary reconstruction based on two or more projections in a calibrated X-ray C-arm system. The results of the study give insight into the quantitative accuracy of the calculated 3D centerline points and the 3D cross sectional areas of reconstructed objects as a function of the angular distance and the total number of calibrated projections involved. A confidence region (alpha(0) approximate to 30degrees - 145degrees) for the angular relation of the involved projections was determined, for which the presented modeling technique is capable of providing nearly geometrically exact 3D centerline position of the coronary arteries. The method for the generation of such an angular confidence region can be adapted to any calibrated angiographic mono- plane C-arm system. Within this angular region, we are able to reconstruct, different branches of the same coronary tree by identifying their corresponding 2D centerlines and vessel lumen in different 2D projections. The measurements in this work are based on the analysis of calibrated phantom and calibrated cardiovascular 2D projection data.
引用
收藏
页码:878 / 880
页数:3
相关论文
共 50 条
  • [31] 3D Coronary Vessel Tree Tracking in X-Ray Projections
    Poulain, Emmanuelle
    Malandain, Gregoire
    Vaillant, Regis
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, FIMH 2019, 2019, 11504 : 388 - 396
  • [32] Quantitative Analysis and 2D/3D Elemental Imaging of Cocoa Beans Using X-ray Fluorescence Techniques
    Forste, Frank
    Bauer, Leona
    Streeck, Cornelia
    Radtke, Martin
    Reinholz, Uwe
    Kadow, Daniel
    Keil, Claudia
    Mantouvalou, Ioanna
    ANALYTICAL CHEMISTRY, 2023, 95 (13) : 5627 - 5634
  • [33] Noninvasive MR to 3D rotational X-ray registration of vertebral bodies
    van de Kraats, EB
    van Walsum, T
    Verlaan, JJ
    Niessen, WJ
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1101 - 1108
  • [34] A method for 3D flow determination based on X-ray rotational angiography
    Grass, M
    Schmitt, H
    Rasche, V
    Haehnel, S
    Schramm, O
    Hartmann, M
    Sartor, K
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 390 - 395
  • [35] 3D X-RAY IMAGE COMPOSITION
    Armeanu, Constantin Catalin
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2016, 78 (01): : 309 - 320
  • [36] X-ray holography: Atoms in 3D
    Tegze, M
    Faigel, G
    Bortel, G
    Marchesini, S
    Belakhovsky, M
    Simionovici, A
    JOURNAL OF ALLOYS AND COMPOUNDS, 2005, 401 (1-2) : 92 - 98
  • [37] X-ray holography: Atoms in 3D
    Tegze, M.
    Faigel, G.
    Bortel, G.
    Marchesini, S.
    Belakhovsky, M.
    Simionovici, A.
    Journal of Alloys and Compounds, 2005, 401 (1-2): : 92 - 98
  • [38] 3D X-ray crystal microscope
    Ice, GE
    Larson, BC
    ADVANCED ENGINEERING MATERIALS, 2000, 2 (10) : 643 - 646
  • [39] 3D discrete X-ray transform
    Averbuch, A
    Shkolnisky, Y
    APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2004, 17 (03) : 259 - 276
  • [40] Quantitative 3D imaging of whole, unstained cells by using X-ray diffraction microscopy
    Jiang, Huaidong
    Song, Changyong
    Chen, Chien-Chun
    Xu, Rui
    Raines, Kevin S.
    Fahimian, Benjamin P.
    Lu, Chien-Hung
    Lee, Ting-Kuo
    Nakashima, Akio
    Urano, Jun
    Ishikawa, Tetsuya
    Tamanoi, Fuyuhiko
    Miao, Jianwei
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (25) : 11234 - 11239