Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention

被引:5
作者
Bourbotte-Salmon, Florian [1 ]
Ferry, Tristan [2 ,3 ,4 ,5 ]
Cardinale, Mickael [6 ]
Servien, Elvire [3 ,4 ,7 ]
Rongieras, Frederic [1 ]
Fessy, Michel-Henry [3 ,4 ,8 ]
Bertani, Antoine [1 ]
Laurent, Frederic [3 ,4 ,9 ]
Buffe-Lidove, Margaux [10 ]
Batailler, Cecile [3 ,4 ,7 ]
Lustig, Sebastien [3 ,4 ,7 ]
机构
[1] Hop Edouard Herriot, Dept Orthopaed & Traumatol Surg, Lyon, France
[2] Hosp Civils Lyon, Serv Malad Infectieuses & Trop, Hop Croix Rousse, Lyon, France
[3] Univ Claude Bernard Lyon 1, Lyon, France
[4] Hosp Civils Lyon, Ctr Interreg Reference Prise Charge Infect Osteoa, Lyon, France
[5] Univ Lyon, Univ Claude Bernard Lyon 1, CNRS,UMR5308, CIRI Ctr Int Rech Infectiol,Inserm,U1111,Ecole No, Lyon, France
[6] Hop Instruct Armees St Anne, Dept Anesthesiol & Intens Care, Toulon, France
[7] Hop Croix Rousse, Dept Orthopaed & Sport Surg, Lyon, France
[8] Ctr Hosp Lyon Sud, Dept Orthopaed & Traumatol Surg, Pierre Benite, France
[9] Hop Croix Rousse, Inst Agents Infectieux, Lyon, France
[10] Hop Instruct Armees Desgenettes, Dept Phys & Rehabil Med, Lyon, France
来源
FRONTIERS IN SURGERY | 2021年 / 8卷
关键词
arthroplasty; total knee arthroplasty; knee prosthesis; prosthetic-joint infection; septic revision; superinfection; prevention; REPLACEMENT; RECOMMENDATIONS; RECONSTRUCTION; COMPLICATIONS; DIAGNOSIS; RESECTION; IMPLANTS; SURVIVAL; EXCHANGE; PROTOCOL;
D O I
10.3389/fsurg.2021.551814
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Management of chronic infection following total knee arthroplasty (TKA) is challenging. Rotating hinged prostheses are often required in this setting due to severe bone loss, ligamentous insufficiency, or a combination of the two. The nature of the mechanical and septic complications occurring in this setting has not been well-described. The aim of this study was to evaluate patient outcomes using a hinge knee prosthesis for prosthetic knee infections and to investigate risk factors for implant removal.</p> Methods: This was a retrospective cohort study that included all patients treated in our tertiary level referral center between January 2009 and December 2016 for prosthetic knee infection with a hinge knee prosthesis. Only patients with a minimum 2-year of follow-up were included. Functional evaluation was performed using international knee society (IKS) "Knee" and "Function" scores. Survival analysis comparing implant removal risks for mechanical and septic causes was performed using Cox univariate analysis and Kaplan-Meier curves. Risk factors for implant removal and septic failure were assessed.</p> Results: Forty-six knees were eligible for inclusion. The majority of patients had satisfactory functional outcomes as determined by mean IKS scores (mean knee score: 70.53, mean function score: 46.53 points, and mean knee flexion: 88.75 degrees). The 2-year implant survival rate was 89% but dropped to 65% at 7 years follow-up. The risk of failure (i.e., implant removal) was higher for septic etiology compared to mechanical causes. Patients with American society of anesthesiologists (ASA) score>1, immunosuppression, or with peripheral arterial diseases had a higher risk for septic failure. Patients with acute infection according to the Tsukayamaclassification had a higher risk of failure. Of the 46 patients included, 19 (41.3%) had atleast one infectious event on the surgical knee and most of these were superinfections (14/19) with new pathogens isolated. Among pathogens responsible for superinfections (i) cefazolin and gentamicin were both active in six of the cases but failed to prevent the superinfection; (ii) cefazolin and/or gentamicin were not active in eight patients, leading to alternative systemic and/or local antimicrobial prophylaxis consideration.</p> Conclusions: Patients with chronic total knee arthroplasty (TKA) infection, requiring revision using rotating hinge implant, had good functional outcomes but experienced a high rate of septic failure, mostly due to bacterial superinfection. These patients may need optimal antimicrobial systemic prophylaxis and innovative approaches to reduce the rate of superinfection.</p>
引用
收藏
页数:12
相关论文
共 48 条
  • [1] Rotating-hinge knee prosthesis as a viable option in primary surgery: Literature review & meta-analysis
    Abdulkarim, Ali
    Keane, Anna
    Hu, Shu Yang
    Glen, Lachlan
    Murphy, Dermot J.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (07) : 1351 - 1359
  • [2] [Anonymous], 2018, GLOB GUID PREV SURG
  • [3] Antibioprophylaxie en chirurgie et medecine interventionnelle (patients adultes)-La SFAR, 2015, ANT CHIR MED INT PAT
  • [4] Appleton P, 2006, J BONE JOINT SURG BR, V88B, P1065, DOI 10.1302/0301-620X.88B8
  • [5] Executive summary of management of prosthetic joint infections. Clinical practice guidelines by the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC)
    Ariza, Javier
    Cobo, Javier
    Baraia-Etxaburu, Josu
    Benito, Natividad
    Bori, Guillermo
    Cabo, Javier
    Corona, Pablo
    Esteban, Jaime
    Horcajada, Juan Pablo
    Lora-Tamayo, Jaime
    Murillo, Oscar
    Palomino, Julian
    Parra, Jorge
    Pigrau, Carlos
    del Pozo, Jose Luis
    Riera, Melchor
    Rodriguez, Dolores
    Sanchez-Somolinos, Mar
    Soriano, Alex
    del Toro, M. Dolores
    de la Torre, Basilio
    [J]. ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2017, 35 (03): : 189 - 195
  • [6] Barrack RL, 2001, CLIN ORTHOP RELAT R, P292
  • [7] Effect of a Preoperative Decontamination Protocol on Surgical Site Infections in Patients Undergoing Elective Orthopedic Surgery With Hardware Implantation
    Bebko, Serge P.
    Green, David M.
    Awad, Samir S.
    [J]. JAMA SURGERY, 2015, 150 (05) : 390 - 395
  • [8] Statistics notes - Survival probabilities (the Kaplan-Meier method)
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1998, 317 (7172) : 1572 - 1572
  • [9] Midterm Results of a New Rotating Hinge Knee Implant: A 5-Year Follow-Up
    Boehler, Christoph
    Kolbitsch, Paul
    Schuh, Reinhard
    Lass, Richard
    Kubista, Bernd
    Giurea, Alexander
    [J]. BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [10] Indications, Survivorship, and Clinical Outcomes of a Rotating Hinge Total Knee and Distal Femoral Arthroplasty System
    Chaudhry, Harman
    MacDonald, Steven J.
    Howard, James L.
    Lanting, Brent A.
    McCalden, Richard W.
    Naudie, Douglas D.
    Vasarhelyi, Edward M.
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (05) : 1323 - 1327