Quantitative imaging of trace elements in brain sections of Alzheimer's disease mice with laser ablation inductively coupled plasma-mass spectrometry

被引:14
|
作者
Liu, Jinhui [1 ,2 ,3 ,4 ]
Zheng, Lingna [2 ,3 ,4 ]
Wei, Xing [1 ]
Wang, Bing [2 ,3 ,4 ]
Chen, Hanqing [2 ,5 ]
Chen, Mingli [1 ]
Wang, Meng [2 ,3 ,4 ]
Feng, Weiyue [2 ,3 ,4 ]
Wang, Jianhua [1 ]
机构
[1] Northeastern Univ, Dept Chem, Coll Sci, Res Ctr Analyt Sci, Shenyang 110819, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, CAS Key Lab Biomed Effects Nanomat & Nanosafety, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Beijing Metall Facil, Inst High Energy Phys, Beijing 100049, Peoples R China
[4] Chinese Acad Sci, CAS HKU Joint Lab Metall Hlth & Environm, Inst High Energy Phys, Beijing 100049, Peoples R China
[5] South China Univ Technol, Dept Gastroenterol, Guangzhou Digest Dis Ctr, Guangzhou First Peoples Hosp,Sch Med, Guangzhou 510180, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
LA-ICP-MS; Trace elements; Alzheimer's disease; Quantitative imaging; LA-ICP-MS; THIN-SECTION; COPPER; METAL; TISSUES; ZINC; HIPPOCAMPUS; CHEMISTRY;
D O I
10.1016/j.microc.2021.106912
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has become a powerful technique for imaging of trace elements in biological samples. However, accurately quantitative imaging is still a complicated task due to lack of matrix-matched standard materials. On the other hand, traditional LA-ICP-MS analysis usually suffers from slow analytical speed and low imaging resolution mainly due to a long washout time of an ablation cell and a low repetition rate of a laser. In this work, a series of homemade matrix-matched standards were produced by homogeneous spiking of gelatin with a known amount of trace elements (Fe, Cu, and Zn). Using these standards, quantitative imaging of Fe, Cu, and Zn in the brains of Alzheimer's disease (AD) and control mice were achieved using a laser ablation system with a low-dispersion cell and a high repetition rate laser coupled to a triple quadrupole ICP-MS. The limits of detection of Fe, Cu, and Zn are 5.4 mu g g(-1), 0.081 mu g g(-1), and 0.54 mu g g(-1), respectively. The concentrations of Fe, Cu, and Zn in mouse brains are 10 similar to 70 mu g g(-1), 5 -30 mu g g(-1) these metals between AD and control mouse brains. The developed LA-ICP-MS approach is expected to provide a new insight into biological effects of metals and aetiology of metal-related diseases. , and 25 similar to 150 mu g g(-1), respectively. The quantitative imaging shows different distribution and contents of
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Bio-imaging of metals in a mouse model of Alzheimer's disease by laser ablation inductively coupled plasma mass spectrometry
    Matusch, Andreas
    Becker, J. Sabine
    BIOMEDICAL SPECTROSCOPY AND IMAGING, 2012, 1 (01) : 57 - 65
  • [32] Determination of Major and Trace Elements in Plant Samples by Inductively Coupled Plasma-Mass Spectrometry
    Masson, P.
    Dalix, T.
    Bussiere, S.
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2010, 41 (03) : 231 - 243
  • [33] Determination of Trace Elements in High Purity Gold by Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Chen X.
    Hu F.
    Zang M.
    Sun Z.
    Liu Y.
    Tong J.
    Xiyou Jinshu/Chinese Journal of Rare Metals, 2021, 45 (03): : 333 - 340
  • [34] Quantification strategies for elemental imaging of biological samples using laser ablation-inductively coupled plasma-mass spectrometry
    Hare, Dominic
    Austin, Christine
    Doble, Philip
    ANALYST, 2012, 137 (07) : 1527 - 1537
  • [35] Quantitative Imaging of Silver Nanoparticles and Essential Elements in Thin Sections of Fibroblast Multicellular Spheroids by High Resolution Laser Ablation Inductively Coupled Plasma Time-of-Flight Mass Spectrometry
    Arakawa, Akihiro
    Jakubowski, Norbert
    Koellensperger, Gunda
    Theiner, Sarah
    Schweikert, Andreas
    Flemig, Sabine
    Iwahata, Daigo
    Traub, Heike
    Hirata, Takafumi
    ANALYTICAL CHEMISTRY, 2019, 91 (15) : 10197 - 10203
  • [36] Quantitative mapping of mercury and selenium in mushroom fruit bodies with laser ablation–inductively coupled plasma-mass spectrometry
    Simone Braeuer
    Tom Van Helden
    Thibaut Van Acker
    Olivier Leroux
    Dominique Van Der Straeten
    Annemieke Verbeken
    Jan Borovička
    Frank Vanhaecke
    Analytical and Bioanalytical Chemistry, 2022, 414 : 7517 - 7530
  • [37] Progress in Combination of Gel Electrophoresis and Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Trace Elements Determination in Proteins
    Wang Ying
    Guo Yan-li
    Yuan Hong-lin
    Wei Yong-feng
    Yan Hong-tao
    Chen Hui-hui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (01) : 223 - 228
  • [38] Quantitative imaging of platinum based on laser ablation-inductively coupled plasma-mass spectrometry to investigate toxic side effects of cisplatin
    Koeppen, C.
    Reifschneider, O.
    Castanheira, I.
    Sperling, M.
    Karst, U.
    Ciarimboli, G.
    METALLOMICS, 2015, 7 (12) : 1595 - 1603
  • [39] Quantitative titanium imaging in fish tissues exposed to titanium dioxide nanoparticles by laser ablation-inductively coupled plasma-mass spectrometry
    Cristian Suárez-Oubiña
    Annarosa Mangone
    Lorena C. Giannossa
    Laura Nuñez-González
    Paloma Herbello-Hermelo
    Pilar Bermejo-Barrera
    Antonio Moreda-Piñeiro
    Microchimica Acta, 2023, 190
  • [40] Using laser ablation/inductively coupled plasma mass spectrometry to bioimage multiple elements in mouse tumors after hyperthermia
    Hsieh, Yi-Kong
    Jiang, Pei-Shin
    Yang, Bing-Shen
    Sun, Tian-Ye
    Peng, Hsu-Hsia
    Wang, Chu-Fang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (03) : 909 - 915