Study on the mechanical behavior of a foundation pit retaining structure adjacent to the pile foundation of a subway station

被引:11
|
作者
Zhang, Qian [1 ]
Hu, Jie [2 ]
Wang, Jing [3 ]
He, Peng [4 ]
Hou, Lili [1 ]
Lin, Peng [3 ]
Song, Shuguang [5 ]
机构
[1] Shijiazhuang Tiedao Univ, Shijiazhuang 050043, Hebei, Peoples R China
[2] Nanjing Univ Sci & Technol, Sch Mech Engn, Nanjing 210094, Peoples R China
[3] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Shandong, Peoples R China
[4] China Railway First Grp Co Ltd, Xian 710000, Shanxi, Peoples R China
[5] Shandong Jianzhu Univ, Jinan 250003, Shandong, Peoples R China
基金
国家重点研发计划; 中国博士后科学基金;
关键词
Subway; Foundation pit engineering; Limited soil; Earth pressure; Laboratory model test; EARTH PRESSURE; PERFORMANCE; SETTLEMENT; WALL;
D O I
10.1007/s12665-021-09996-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The numerous effects of adjacent structures should be considered in the design and construction of subway stations. The subway station expansion project confined to a small space in Shenzhen City was taken as engineering background to study the earth pressure distribution in a limited space. Both theoretical analysis and laboratory model testing methods were used to study the mechanical behavior of the subway station retaining structure adjacent to a pile foundation. The main conclusions are as follows: (1) When the soil around the foundation pit is non-cohesive, the soil pressure is smaller than that calculated by classical soil pressure theory, and the difference between the two increases with an increase in the angle of internal friction. If the lateral inclination continues to increase, then the pressure will approach the value determined by classical theory. (2) The soil pressure distribution and variation rule are greatly influenced by factors such as the length-diameter ratio, excavation depth, internal friction angle and friction between the soil and retaining structure. The dip angle of the sliding surface of the finite soil increases with decreasing friction angle and is inversely correlated with the aspect ratio. The active soil pressure is inversely proportional to the internal friction angle of the soil and positively correlated with height. When the internal friction angle is constant and the length-diameter ratio is equal to the critical length-diameter ratio, the active earth pressure coefficient is equal to the Coulomb active earth pressure coefficient and reaches its maximum value. (3) The deformation of the foundation pit retaining structure has an important influence on the distribution of soil pressure around it. These results offer a reference for the engineering design and construction of supporting structures for deep foundation pits adjacent to existing adjacent structures.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] The Application of Anchor Pile in Foundation Pit Supporting Structure
    Zhang, Xin-zhong
    Zhao, Long
    Tang, Ke-dong
    3RD INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE, ICCEASI 2015, 2015, : 982 - 987
  • [42] Evaluation and Optimization of the Corner Effect of a Deep Foundation Pit Adjacent to a Subway Tunnel
    Dong, Xin
    Zhou, Feng
    Chen, Tingzhu
    Zhu, Rui
    Wang, Xudong
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2024, 24 (09)
  • [43] Effect of pit excavation on subway foundation
    Hu, Heng
    Zhu, Hou-Xi
    Jia, Li-Hong
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2010, 32 (SUPPL. 1): : 116 - 119
  • [44] Unloading Mechanical Effect Analysis of Retaining Structure of Deep Foundation Pit in Soft Soil
    Zhang, Leiyu
    Hao, Zhenjie
    Chai, Shufeng
    Zhou, Yuxin
    2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252
  • [45] Field Monitoring Analysis of Construction Process of Deep Foundation Pit at Subway Station
    Wang, Zhongchang
    Guo, Xinping
    Wang, Chuan
    GEOTECHNICAL AND GEOLOGICAL ENGINEERING, 2019, 37 (02) : 549 - 559
  • [46] Field Monitoring Analysis of Construction Process of Deep Foundation Pit at Subway Station
    Zhongchang Wang
    Xinping Guo
    Chuan Wang
    Geotechnical and Geological Engineering, 2019, 37 : 549 - 559
  • [47] An Integrated Intelligent Approach for Monitoring and Management of a Deep Foundation Pit in a Subway Station
    Hong, Chengyu
    Zhang, Jinyang
    Chen, Weibin
    SENSORS, 2022, 22 (22)
  • [48] Improvement of incremental calculation method of retaining structure for foundation pit
    Liu Cheng-yu
    Chen Shu-yun
    ROCK AND SOIL MECHANICS, 2018, 39 (05) : 1834 - 1839
  • [49] Improved Method of Calculating the Influence of Foundation Pit Excavation on Adjacent Single Pile
    Shi C.
    Liu J.
    Wang Z.
    Peng L.
    Yang G.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2019, 47 (10): : 105 - 113
  • [50] Analysis of the influence of foundation pit excavation on viaduct pile foundation
    Cheng, Zhiyong
    Liu, Jinyan
    Modern Tunnelling Technology, 2014, 51 : 322 - 327