Study on the mechanical behavior of a foundation pit retaining structure adjacent to the pile foundation of a subway station

被引:11
作者
Zhang, Qian [1 ]
Hu, Jie [2 ]
Wang, Jing [3 ]
He, Peng [4 ]
Hou, Lili [1 ]
Lin, Peng [3 ]
Song, Shuguang [5 ]
机构
[1] Shijiazhuang Tiedao Univ, Shijiazhuang 050043, Hebei, Peoples R China
[2] Nanjing Univ Sci & Technol, Sch Mech Engn, Nanjing 210094, Peoples R China
[3] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Shandong, Peoples R China
[4] China Railway First Grp Co Ltd, Xian 710000, Shanxi, Peoples R China
[5] Shandong Jianzhu Univ, Jinan 250003, Shandong, Peoples R China
基金
中国博士后科学基金; 国家重点研发计划;
关键词
Subway; Foundation pit engineering; Limited soil; Earth pressure; Laboratory model test; EARTH PRESSURE; PERFORMANCE; SETTLEMENT; WALL;
D O I
10.1007/s12665-021-09996-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The numerous effects of adjacent structures should be considered in the design and construction of subway stations. The subway station expansion project confined to a small space in Shenzhen City was taken as engineering background to study the earth pressure distribution in a limited space. Both theoretical analysis and laboratory model testing methods were used to study the mechanical behavior of the subway station retaining structure adjacent to a pile foundation. The main conclusions are as follows: (1) When the soil around the foundation pit is non-cohesive, the soil pressure is smaller than that calculated by classical soil pressure theory, and the difference between the two increases with an increase in the angle of internal friction. If the lateral inclination continues to increase, then the pressure will approach the value determined by classical theory. (2) The soil pressure distribution and variation rule are greatly influenced by factors such as the length-diameter ratio, excavation depth, internal friction angle and friction between the soil and retaining structure. The dip angle of the sliding surface of the finite soil increases with decreasing friction angle and is inversely correlated with the aspect ratio. The active soil pressure is inversely proportional to the internal friction angle of the soil and positively correlated with height. When the internal friction angle is constant and the length-diameter ratio is equal to the critical length-diameter ratio, the active earth pressure coefficient is equal to the Coulomb active earth pressure coefficient and reaches its maximum value. (3) The deformation of the foundation pit retaining structure has an important influence on the distribution of soil pressure around it. These results offer a reference for the engineering design and construction of supporting structures for deep foundation pits adjacent to existing adjacent structures.
引用
收藏
页数:10
相关论文
共 20 条
  • [11] Regional-scale co-seismic landslide assessment using limit equilibrium analysis
    Saade, Angela
    Abou-Jaoude, Grace
    Wartman, Joseph
    [J]. ENGINEERING GEOLOGY, 2016, 204 : 53 - 64
  • [12] Basal-heave analysis of pit-in-pit braced excavations in soft clays
    Sun, Yuyong
    Zhou, Shunhua
    Luo, Zhe
    [J]. COMPUTERS AND GEOTECHNICS, 2017, 81 : 294 - 306
  • [13] Enhanced analysis of pile flexural behavior due to installation of adjacent pile
    Tho, Kee Kiat
    Chen, Zongrui
    Leung, Chun Fai
    Chow, Yean Khow
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2014, 51 (06) : 705 - 711
  • [14] Numerical study of dewatering in a large deep foundation pit
    Wang, Jianxiu
    Feng, Bo
    Yu, Haipeng
    Guo, Taiping
    Yang, Guangyun
    Tang, Junwu
    [J]. ENVIRONMENTAL EARTH SCIENCES, 2013, 69 (03) : 863 - 872
  • [15] Wang Kui-hua, 2010, Journal of Zhejiang University, V44, P969, DOI 10.3785/j.issn.1008-973X.2010.05.022
  • [16] Design and performance of the deep excavation of a substation constructed by top-down method in Shanghai soft soils
    Weng, Qiping
    Xu, Zhonghua
    Wu, Zhihou
    Liu, Ruobiao
    [J]. 15TH INTERNATIONAL SCIENTIFIC CONFERENCE UNDERGROUND URBANISATION AS A PREREQUISITE FOR SUSTAINABLE DEVELOPMENT, 2016, 165 : 682 - 694
  • [17] Sensor monitoring of a newly designed foundation pit supporting structure
    Yang Yu-you
    Lu Jian-guo
    Huang Xue-gang
    Tu Xiao-ming
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2013, 20 (04) : 1064 - 1070
  • [18] Bearing strength surface for bridge caisson foundations in frictional soil under combined loading
    Zafeirakos, Athanasios
    Gerolymos, Nikos
    [J]. ACTA GEOTECHNICA, 2016, 11 (05) : 1189 - 1208
  • [19] Analysis of excavation-induced responses of loaded pile foundations considering unloading effect
    Zhang, Rongjun
    Zheng, Junjie
    Pu, Hefu
    Zhang, Limin
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2011, 26 (02) : 320 - 335
  • [20] Numerical simulation of deep foundation pit dewatering and optimization of controlling land subsidence
    Zhou, Nianqing
    Vermeer, Pieter A.
    Lou, Rongxiang
    Tang, Yiqun
    Jiang, Simin
    [J]. ENGINEERING GEOLOGY, 2010, 114 (3-4) : 251 - 260