Study on the mechanical behavior of a foundation pit retaining structure adjacent to the pile foundation of a subway station

被引:11
作者
Zhang, Qian [1 ]
Hu, Jie [2 ]
Wang, Jing [3 ]
He, Peng [4 ]
Hou, Lili [1 ]
Lin, Peng [3 ]
Song, Shuguang [5 ]
机构
[1] Shijiazhuang Tiedao Univ, Shijiazhuang 050043, Hebei, Peoples R China
[2] Nanjing Univ Sci & Technol, Sch Mech Engn, Nanjing 210094, Peoples R China
[3] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Shandong, Peoples R China
[4] China Railway First Grp Co Ltd, Xian 710000, Shanxi, Peoples R China
[5] Shandong Jianzhu Univ, Jinan 250003, Shandong, Peoples R China
基金
中国博士后科学基金; 国家重点研发计划;
关键词
Subway; Foundation pit engineering; Limited soil; Earth pressure; Laboratory model test; EARTH PRESSURE; PERFORMANCE; SETTLEMENT; WALL;
D O I
10.1007/s12665-021-09996-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The numerous effects of adjacent structures should be considered in the design and construction of subway stations. The subway station expansion project confined to a small space in Shenzhen City was taken as engineering background to study the earth pressure distribution in a limited space. Both theoretical analysis and laboratory model testing methods were used to study the mechanical behavior of the subway station retaining structure adjacent to a pile foundation. The main conclusions are as follows: (1) When the soil around the foundation pit is non-cohesive, the soil pressure is smaller than that calculated by classical soil pressure theory, and the difference between the two increases with an increase in the angle of internal friction. If the lateral inclination continues to increase, then the pressure will approach the value determined by classical theory. (2) The soil pressure distribution and variation rule are greatly influenced by factors such as the length-diameter ratio, excavation depth, internal friction angle and friction between the soil and retaining structure. The dip angle of the sliding surface of the finite soil increases with decreasing friction angle and is inversely correlated with the aspect ratio. The active soil pressure is inversely proportional to the internal friction angle of the soil and positively correlated with height. When the internal friction angle is constant and the length-diameter ratio is equal to the critical length-diameter ratio, the active earth pressure coefficient is equal to the Coulomb active earth pressure coefficient and reaches its maximum value. (3) The deformation of the foundation pit retaining structure has an important influence on the distribution of soil pressure around it. These results offer a reference for the engineering design and construction of supporting structures for deep foundation pits adjacent to existing adjacent structures.
引用
收藏
页数:10
相关论文
共 20 条
  • [1] A finite element performance-based approach to correlate movement of a rigid retaining wall with seismic earth pressure
    Bakr, Junied
    Ahmad, Syed Mohd
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 114 : 460 - 479
  • [2] Baziar MH, 2015, KSCE J CIV ENG, V19, P98
  • [3] EXTRAMURAL CROSS-VALIDATION OF THE MAYO PRIMARY BILIARY-CIRRHOSIS SURVIVAL MODEL ESTABLISHES ITS GENERALIZABILITY
    GRAMBSCH, PM
    DICKSON, ER
    KAPLAN, M
    LESAGE, G
    FLEMING, TR
    LANGWORTHY, AL
    [J]. HEPATOLOGY, 1989, 10 (05) : 846 - 850
  • [4] Lagged settlement in sandy cobble strata and earth pressure on shield tunnel
    Huang, Jizhi
    Zhang, Yong
    Ouyang, Xiaowei
    Xu, Guoyuan
    [J]. MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2019, 16 (06) : 6209 - 6230
  • [5] Evaluation of the seismic earth pressure for inverted T-shape stiff retaining wall in cohesionless soils via dynamic centrifuge
    Jo, Seong-Bae
    Ha, Jeong-Gon
    Lee, Jin-Sun
    Kim, Dong-Soo
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2017, 92 : 345 - 357
  • [6] [梁发云 Liang Fayun], 2012, [岩土力学, Rock and Soil Mechanics], V33, P657
  • [7] Numerical analysis on the mechanical performance of supporting structures and ground settlement characteristics in construction process of subway station built by Pile-Beam-Arch method
    Liu, Xinrong
    Liu, Yongquan
    Yang, Zhongping
    He, Chunmei
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2017, 21 (05) : 1690 - 1705
  • [8] BIM-based framework for managing performance of subway stations
    Marzouk, Mohamed
    Abdelaty, Ahmed
    [J]. AUTOMATION IN CONSTRUCTION, 2014, 41 : 70 - 77
  • [9] Effects of the construction sequence of twin tunnels at different depths on an existing pile
    Ng, C. W. W.
    Lu, H.
    [J]. CANADIAN GEOTECHNICAL JOURNAL, 2014, 51 (02) : 173 - 183
  • [10] Peck RB., 1995, SOIL MECH ENG PRACTI, V3