Gastrointestinal endoscope contamination rates - elevators are not only to blame: a systematic review and meta-analysis

被引:10
作者
Goyal, Hemant [1 ,2 ]
Larsen, Sara [3 ]
Perisetti, Abhilash [4 ]
Larsen, Nikolaj Birk [5 ]
Ockert, Lotte Klinten [1 ]
Adamsen, Sven [1 ,6 ]
Tharian, Benjamin [7 ]
Thosani, Nirav [8 ]
机构
[1] UTHealth iGUT, McGovern Med Sch, Div Gastroenterol Hepatol & Nutr, Ctr Intervent Gastroenterol, Houston, TX USA
[2] Mercer Univ, Sch Med, Macon, GA 31207 USA
[3] Ambu AS, Ballerup, Denmark
[4] Parkview Canc Inst, Div Intervent Oncol & Surg Endoscopy IOSE, Wayne, IN USA
[5] Aalborg Univ, Fac Med, Aalborg, Denmark
[6] Univ Copenhagen, Bispebjerg Hosp, Ctr Digest Dis, Copenhagen, Denmark
[7] Univ Arkansas Med Sci, Gen & Adv Endoscopy, Med, Little Rock, AR 72205 USA
[8] UTHealth, McGovern Med Sch, Div Gastroenterol Hepatol & Nutr, Ctr Intervent Gastroenterol,UTHealth iGUT, Houston, TX USA
关键词
HIGH-LEVEL DISINFECTION; MICROBIOLOGICAL SURVEILLANCE; FLEXIBLE BRONCHOSCOPES; DUODENOSCOPE; TRANSMISSION; INFECTION; CULTURE; RISK; QUARANTINE; GUIDELINE;
D O I
10.1055/a-1795-8883
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims Duodenoscopes that are contaminated due to inadequate reprocessing are well-documented. However, studies have demonstrated poor reprocessing of other kinds of endoscopes as well, including echoendoscopes, gastroscopes, and colonoscopes. We estimated the contamination rate beyond the elevator of gastrointestinal endoscopes based on available data. Methods We searched PubMed and Embase from January 1, 2010 to October 10, 2020, for studies investigating contamination rates of reprocessed gastrointestinal endoscopes. A random-effects model was used to calculate the contamination rate of patient-ready gastrointestinal endoscopes. Subgroup analyses were conducted to investigate differences among endoscope types, countries, and colony-forming unit (CFU) thresholds. Results Twenty studies fulfilled the inclusion criteria, including 1,059 positive cultures from 7,903 samples. The total contamination rate was 19.98% +/- 0.024 (95% confidence interval [Cl]: 15.29%-24.68 %; I-2=98.6%). The contamination rates of colonoscope and gastroscope channels were 31.95%+/- 0.084 and 28.22%+/- 0.076, respectively. Duodenoscope channels showed a contamination rate of 14.41% +/- 0.029. The contamination rates among studies conducted in North America and Europe were 6.01%+/- 0.011 and 18.16% +/- 0.053 %, respectively. The contamination rate among studies using a CFU threshold > 20 showed contamination of 30.36%+/- 0.094, whereas studies using a CFU threshold < 20 showed a contamination rate of 11%+/- 0.026. Conclusions On average, 19.98% of reprocessed gastrointestinal endoscopes may be contaminated when used in patients and varies between different geographies. These findings highlight that the elevator mechanism is not the only obstacle when reprocessing reusable endoscopes; therefore, guidelines should recommend more surveillance of the endoscope channels as well.
引用
收藏
页码:E840 / E853
页数:14
相关论文
共 47 条
[41]   Remember, interventional EUS is performed using an elevator-containing scope as well [J].
Sun, Siyu ;
Wang, Caixia ;
Wang, Sheng .
ENDOSCOPIC ULTRASOUND, 2018, 7 (02) :73-75
[42]   Outbreak of Pseudomonas aeruginosa Infections from a Contaminated Gastroscope Detected by Whole Genome Sequencing Surveillance [J].
Sundermann, Alexander J. ;
Chen, Jieshi ;
Miller, James K. ;
Saul, Melissa, I ;
Shutt, Kathleen A. ;
Griffith, Marissa P. ;
Mustapha, Mustapha M. ;
Ezeonwuka, Chinelo ;
Waggle, Kady ;
Srinivasa, Vatsala ;
Kumar, Praveen ;
Pasculle, A. William ;
Ayres, Ashley M. ;
Snyder, Graham M. ;
Cooper, Vaughn S. ;
Van Tyne, Daria ;
Marsh, Jane W. ;
Dubrawski, Artur W. ;
Harrison, Lee H. .
CLINICAL INFECTIOUS DISEASES, 2021, 73 (03) :E638-E642
[43]   Inspection of endoscope instrument channels after reprocessing using a prototype borescope [J].
Thaker, Adarsh M. ;
Kim, Stephen ;
Sedarat, Alireza ;
Watson, Rabindra R. ;
Muthusamy, V. Raman .
GASTROINTESTINAL ENDOSCOPY, 2018, 88 (04) :612-619
[44]  
Travis HS., 2020, PHARMACOECONOM OPEN, V5, P3
[45]   Microbiological surveillance of flexible bronchoscopes after a high-level disinfection with peracetic acid: preliminary results from an Italian teaching hospital [J].
Troiano, G. ;
Lo Nostro, A. ;
Calonico, C. ;
Nante, N. ;
Magistri, L. ;
Pulci, M. B. ;
Niccolini, F. .
ANNALI DI IGIENE MEDICINA PREVENTIVA E DI COMUNITA, 2019, 31 (01) :13-20
[46]  
U.S. Food and Drug Administration, About us
[47]   Rates of infection after colonoscopy and osophagogastroduodenoscopy in ambulatory surgery centres in the USA [J].
Wang, Peiqi ;
Xu, Tim ;
Ngamruengphong, Saowanee ;
Makary, Martin A. ;
Kalloo, Anthony ;
Hutfless, Susan .
GUT, 2018, 67 (09) :1626-1636