Corona lightning overvoltage analysis for a 500 kV hybrid line

被引:9
|
作者
Said, Abdelrahman [1 ]
Anane, Zahira [2 ]
机构
[1] Benha Univ, Fac Engn Shoubra, Elect Power & Machine Dept, Cairo, Egypt
[2] Univ Setif 1, Dept Elect Engn, Automat Lab Setif, Maabouda, Algeria
关键词
corona; arresters; gas insulated transmission lines; lightning protection; power cable insulation; substation insulation; hybrid power systems; power transmission protection; corona lightning overvoltage analysis; overhead transmission lines; underground system; substation; high-voltage power system components; gas-insulated line; indirect lightning strokes; fully cable system; stressing system components; GIL line; hybrid OHTL-cable-GIL circuit system; high lightning overvoltage distributions; power grid operators; insulations; transient programme; EMTP simulation programme; voltage; 500; 0; kV; TRANSMISSION-LINES; MODEL; EMTP;
D O I
10.1049/iet-gtd.2019.1367
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the overvoltage distributions due to the lightning stroke are analyzed for a 500 kV hybrid OHTL-Cable-GIL circuit beside substation, in which the section length is variable. Corona effect is incorporating in order to estimate the attenuation and deformation of overvoltage's travelling waves on transmission lines near substations. The influence of connecting substations surge arrester, direct, and indirect lightning strokes are investigated. ATP/Electro Magnetic Transients Program(EMTP) simulation program is applied to analyze the lightning overvoltage of a 500 kV hybrid OHTL-Cable-GIL system. It was discovered that OHTL-Cable, OHTL-GIL, and hybrid systems produces lightning overvoltages higher than those of a fully cable system and very likely lower than those of a fully OHTL system with the same transmission lengths. This means that the risk of experiencing high lightning overvoltages and stressing system components is higher in a fully-Overhead Line (OHL)circuit than in a partial or full cable or GIL line. Furthermore, using the Cable with MOSA (Metal Oxide Surge Arrester), the results have more regular voltage waveform at substation entrance; also Hybrid line has the same effect of fully GIL. Finally, the corona has a less attenuation effect of overvoltage reached to substation by about 2.7% in case short length OHTL.
引用
收藏
页码:532 / 541
页数:10
相关论文
共 50 条
  • [11] Observation of Overvoltage at the Terminal of 10 kV Distribution Line by Direct Triggered Lightning
    Wang, Jianguo
    Zhao, Yating
    Fang, Yuquan
    Cai, Li
    Wang, Shoupeng
    Xu, Zhiling
    Cheng, Si
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 3547 - 3554
  • [12] Switching Overvoltage Research of ±500 kV Flexible HVDC Grid With Overhead Line
    Sun X.
    Chen S.
    Huang T.
    Lie X.
    Jiang W.
    Wu Y.
    Chen Y.
    Sun, Xu (sunxu_bj@163.com), 1600, Power System Technology Press (41): : 1498 - 1502
  • [13] Lightning surge characteristics of an actual distribution line and validation of a distribution line model for lightning overvoltage studies
    Electric Power Engineering Research Lab., CRIEPI, 2-6-1, Nagasaka, Yokosuka 240-0196, Japan
    IEEJ Trans. Power Energy, 2008, 9 (1150-1158+9): : 1150 - 1158+9
  • [14] Modeling of surge corona on line conductors: Application to lightning surge analysis
    Bousiou, Evanthia I.
    Stracqualursi, Erika
    Mikropoulos, Pantelis N.
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 246
  • [15] Effect of Line Voltage on Lightning Attachment to 220-kV and 500-kV Lines
    Podporkin, Georgy
    2017 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIV SIPDA), 2017, : 7 - 13
  • [16] A Distribution Line Model for Lightning Overvoltage Studies
    Matsuura, Susumu
    Noda, Taku
    Asakawa, Akira
    Yokoyama, Shigeru
    ELECTRICAL ENGINEERING IN JAPAN, 2010, 173 (01) : 11 - 23
  • [17] Winding Overvoltage Characteristic Analysis of Modular Cascade Isolating Energy Supply Transformer of ±500 kV Hybrid HVDC Breaker
    Zhang, Sheng
    Fan, Yadong
    Wang, Jianguo
    Liu, Yuan
    Zhou, Wandi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (02) : 1248 - 1258
  • [18] Development and application of lightning flashover limited equipment for 220kV AC transmission line
    Cao, Wei
    Wan, Shuai
    Gu, Shanqiang
    Xu, Heng
    Chen, Jiahong
    Wang, Jian
    Lv, Jun
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 802 - 805
  • [19] Lightning Surge Analysis of Transmission Line Towers With a Hybrid FDTD-PEEC Method
    Cao, Jinxin
    Du, Yaping
    Ding, Yuxuan
    Li, Binghao
    Qi, Ruihan
    Zhang, Yang
    Li, Zhe
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (02) : 1275 - 1284
  • [20] Statistical analysis on measured lightning overvoltage surges in a 110 kV air-insulated substation
    Sima, Wenxia
    Lan, Xing
    Yang, Qing
    Yuan, Tao
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (01) : 28 - 36