Corona lightning overvoltage analysis for a 500 kV hybrid line

被引:9
|
作者
Said, Abdelrahman [1 ]
Anane, Zahira [2 ]
机构
[1] Benha Univ, Fac Engn Shoubra, Elect Power & Machine Dept, Cairo, Egypt
[2] Univ Setif 1, Dept Elect Engn, Automat Lab Setif, Maabouda, Algeria
关键词
corona; arresters; gas insulated transmission lines; lightning protection; power cable insulation; substation insulation; hybrid power systems; power transmission protection; corona lightning overvoltage analysis; overhead transmission lines; underground system; substation; high-voltage power system components; gas-insulated line; indirect lightning strokes; fully cable system; stressing system components; GIL line; hybrid OHTL-cable-GIL circuit system; high lightning overvoltage distributions; power grid operators; insulations; transient programme; EMTP simulation programme; voltage; 500; 0; kV; TRANSMISSION-LINES; MODEL; EMTP;
D O I
10.1049/iet-gtd.2019.1367
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the overvoltage distributions due to the lightning stroke are analyzed for a 500 kV hybrid OHTL-Cable-GIL circuit beside substation, in which the section length is variable. Corona effect is incorporating in order to estimate the attenuation and deformation of overvoltage's travelling waves on transmission lines near substations. The influence of connecting substations surge arrester, direct, and indirect lightning strokes are investigated. ATP/Electro Magnetic Transients Program(EMTP) simulation program is applied to analyze the lightning overvoltage of a 500 kV hybrid OHTL-Cable-GIL system. It was discovered that OHTL-Cable, OHTL-GIL, and hybrid systems produces lightning overvoltages higher than those of a fully cable system and very likely lower than those of a fully OHTL system with the same transmission lengths. This means that the risk of experiencing high lightning overvoltages and stressing system components is higher in a fully-Overhead Line (OHL)circuit than in a partial or full cable or GIL line. Furthermore, using the Cable with MOSA (Metal Oxide Surge Arrester), the results have more regular voltage waveform at substation entrance; also Hybrid line has the same effect of fully GIL. Finally, the corona has a less attenuation effect of overvoltage reached to substation by about 2.7% in case short length OHTL.
引用
收藏
页码:532 / 541
页数:10
相关论文
共 50 条
  • [1] Study on the lightning overvoltage protection of a 500kV unified power flow controller station
    Ding, Ting
    Tao, Fengbo
    He, Hengxin
    Zhong, Jiqun
    He, Junjia
    He, Huiwen
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1100 - 1106
  • [2] Analysis on lightning overvoltage of 500kV substation
    Shao Yu
    Shao Ming
    Shi Feng
    Wang Kun
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 1541 - 1545
  • [3] Observation of Lightning Overvoltage in a 500 kV Switching Station
    Sonoda, Toshio
    Morii, Hiroshi
    Sekioka, Shozo
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 1828 - 1834
  • [4] Research on lightning surge overvoltage of convertor station with 500 kV hot-standby circuit breakers
    Fan, Youping
    Wu, Lihui
    Qiu, Huimin
    Wen, Wu
    Liu, Songkai
    Qian, Hai
    Chen, Dong
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2015, 9 (07) : 900 - 907
  • [5] Corona Effects on AC Circuits on an Indonesian 500 kV Hybrid Overhead Line
    Pratama, Andhika Rizki
    Suwarno
    Pischler, Oliver
    Schichler, Uwe
    2019 54TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2019,
  • [6] Study on Influencing Factors of Transmission Line Lightning Overvoltage with Impulse Corona
    Liu, Kai
    Bian, Xingming
    Lu, Tiebing
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [7] Lightning back flashover tripping patterns on a 275/132 kV quadruple circuit transmission line in Malaysia
    Abd Halim, Syahirah
    Abu Bakar, Ab Halim
    Illias, Hazlee Azil
    Hassan, Nor Hidayah Nor
    Mokhlis, Hazlee
    Terzija, Vladimir
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (04) : 344 - 354
  • [8] Study on lightning overvoltage and commutation failure in UHV AC/DC hybrid system
    Fang, Shengwei
    Zhang, Li
    Zou, Liang
    Chen, Yongshuai
    Wang, Yali
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2677 - 2682
  • [9] Induced overvoltage while ±500 kV pole line and neutral line using common-tower
    Chen, Shuiming
    Xie, Haibin
    Tu, Youping
    Zeng, Rong
    Ding, Lijian
    Fan, Lingmeng
    Gaodianya Jishu/High Voltage Engineering, 2012, 38 (05): : 1186 - 1191
  • [10] Analysis of lightning overvoltage according to grounding method and corona effect of lightning arrester in wind farm
    Kim J.-H.
    Kim K.-H.
    Woo J.-W.
    Transactions of the Korean Institute of Electrical Engineers, 2019, 68 (02) : 235 - 240