Soft tissue-based registration of intraoral scan with cone beam computed tomography scan

被引:8
作者
Deferm, J. T. [1 ]
Nijsink, J. [2 ]
Baan, F. [3 ]
Verhamme, L. [3 ]
Meijer, G. [1 ,4 ]
Maal, T. [3 ]
机构
[1] Radboud Univ Nijmegen, Dept Oral & Maxillofacial Surg, Med Ctr, Geert Grootepl 10, NL-6525 GA Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiol Ad Nucl Med, 3D Lab, Med Ctr, Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Dept Oral & Maxillofacial Surg, 3D Lab, Med Ctr, Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Dept Implantol & Periodontol, Med Ctr, Nijmegen, Netherlands
关键词
three-dimensional imaging; cone-beam computed tomography; computer-assisted image processing; edentulous jaw; pre-prosthetic oral surgical procedures; maxilla; mouth; GUIDED IMPLANT-SURGERY;
D O I
10.1016/j.ijom.2021.04.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate a novel soft tissue-based method to register an intraoral scan (IOS) with a cone beam computed tomography (CBCT) scan. IOS and CBCT data were obtained from eight dentate patients (mean age 21 +/- 2 years; three male, five female) and 14 fully edentulous patients (mean age 56 +/- 9 years; eight male, six female). An algorithm was developed to create a soft tissue model of the CBCT scan, which allowed a soft tissue-based registration to be performed with the IOS. First, validation was performed on dentate jaws with registration of the palatal mucosal surface and accuracy evaluation at the level of the teeth. Second, fully edentulous jaws were registered using both the palatal and alveolar crest mucosal surfaces. Distance maps were created to measure the method accuracy. The mean registration error was 0.49 +/- 0.26 mm for the dentate jaws. Registration of the fully edentulous jaws had a mean error of 0.16 +/- 0.08 mm at the palate and 0.16 +/- 0.05 mm at the alveolar crest. In conclusion, the high accuracy of this registration method may allow the digital workflow to be optimized when no teeth are available to perform a regular registration procedure.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 18 条
[1]   Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients with an Intraoral Scanner and Old Complete Denture [J].
An, Xueyin ;
Yang, Hyun-Woo ;
Choi, Byung-Ho .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (06) :715-718
[2]  
[Anonymous], AUTODESK MESHMIXER M
[3]  
[Anonymous], MATLAB manual
[4]  
Arcuri L, 2015, Oral Implantol (Rome), V8, P114, DOI 10.11138/orl/2015.8.4.114
[5]  
DE Vico G, 2016, Oral Implantol (Rome), V9, P33, DOI 10.11138/orl/2016.9.1.033
[6]   Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning [J].
Deferm, Julie T. ;
Schreurs, Ruud ;
Baan, Frank ;
Bruggink, Robin ;
Merkx, Matthijs A. W. ;
Xi, Tong ;
Berge, Stefaan J. ;
Maal, Thomas J. J. .
CLINICAL ORAL INVESTIGATIONS, 2018, 22 (03) :1303-1309
[7]   Registration of cone beam computed tomography data and intraoral surface scans - A prerequisite for guided implant surgery with CAD/CAM drilling guides [J].
Flugge, Tabea ;
Derksen, Wiebe ;
te Poel, Jobine ;
Hassan, Bassam ;
Nelson, Katja ;
Wismeijer, Daniel .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) :1113-1118
[8]   Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues [J].
Gan, Ning ;
Xiong, Yaoyang ;
Jiao, Ting .
PLOS ONE, 2016, 11 (07)
[9]   Multimodality image registration by maximization of mutual information [J].
Maes, F ;
Collignon, A ;
Vandermeulen, D ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :187-198
[10]   Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study [J].
Mangano, Francesco G. ;
Veronesi, Giovanni ;
Hauschild, Uli ;
Mijiritsky, Eitan ;
Mangano, Carlo .
PLOS ONE, 2016, 11 (09)