Microarray-based comparison of three amplification methods for nanogram amounts of total RNA

被引:48
作者
Singh, R
Maganti, RJ
Jabba, SV
Wang, M
Deng, G
Heath, JD
Kurn, N
Wangemann, P
机构
[1] Kansas State Univ, Coll Vet Med, Dept Anat & Physiol, Manhattan, KS 66506 USA
[2] NuGEN Technol Inc, San Carlos, CA USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY | 2005年 / 288卷 / 05期
关键词
gene expression microarray analysis; microdissection; nucleic acid amplification techniques;
D O I
10.1152/ajpcell.00258.2004
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Gene expression profiling using microarrays requires microgram amounts of RNA, which limits its direct application for the study of nanogram RNA samples obtained using microdissection, laser capture microscopy, or needle biopsy. A novel system based on Ribo-SPIA technology (RS, Ovation-Biotin amplification and labeling system) was recently introduced. The utility of the RS system, an optimized prototype system for picogram RNA samples (pRS), and two T7-based systems involving one or two rounds of amplification (OneRA, Standard Protocol, or TwoRA, Small Sample Prototcol, version II) were evaluated in the present study. Mouse kidney (MK) and mouse universal reference (MUR) RNA samples, 0.3 ng to 10 mu g, were analyzed using high-density Affymetrix Mouse Genome 430 2.0 GeneChip arrays. Call concordance between replicates, correlations of signal intensity, signal intensity ratios, and minimal fold increase necessary for significance were determined. All systems amplified partially overlapping sets of genes with similar signal intensity correlations. pRS amplified the highest number of genes from 10-ng RNA samples. We detected 24 of 26 genes verified by RT-PCR in samples prepared using pRS. TwoRA yielded somewhat higher call concordances than did RS and pRS (91.8% vs. 89.3% and 88.1%, respectively). Although all target preparation methods were suitable, pRS amplified the highest number of targets and was found to be suitable for amplification of as little as 0.3 ng of total RNA. In addition, RS and pRS were faster and simpler to use than the T7-based methods and resulted in the generation of cDNA, which is more stable than cRNA.
引用
收藏
页码:C1179 / C1189
页数:11
相关论文
共 24 条
  • [1] Quantitative analysis of mRNA amplification by in vitro transcription
    Baugh, L. R.
    Hill, A. A.
    Brown, E. L.
    Hunter, Craig P.
    [J]. NUCLEIC ACIDS RESEARCH, 2001, 29 (05)
  • [2] DENG G, 2003, 53 ANN M AM SOC HUM
  • [3] Eberwine J, 1996, BIOTECHNIQUES, V20, P584
  • [4] Advantages of mRNA amplification for microarray analysis
    Feldman, AL
    Costouros, NG
    Wang, E
    Qian, M
    Marincola, FM
    Alexander, HR
    Libutti, SK
    [J]. BIOTECHNIQUES, 2002, 33 (04) : 906 - +
  • [5] HEATH J, 2003, 53 ANN M AM SOC HUM
  • [6] Obtaining reliable information from minute amounts of RNA using cDNA microarrays
    Hu, LM
    Wang, J
    Baggerly, K
    Wang, H
    Fuller, GN
    Hamilton, SR
    Coombes, KR
    Zhang, W
    [J]. BMC GENOMICS, 2002, 3 (1)
  • [7] Representation is faithfully preserved in global cDNA amplified exponentially from sub-picogram quantities of mRNA
    Iscove, NN
    Barbara, M
    Gu, M
    Gibson, M
    Modi, C
    Winegarden, N
    [J]. NATURE BIOTECHNOLOGY, 2002, 20 (09) : 940 - 943
  • [8] An evaluation of tyramide signal amplification and archived fixed and frozen tissue in microarray gene expression analysis
    Karsten, SL
    Van Deerlin, VMD
    Sabatti, C
    Gill, LH
    Geschwind, DH
    [J]. NUCLEIC ACIDS RESEARCH, 2002, 30 (02) : 4
  • [9] High-accuracy amplification of nanogram total RNA amounts for gene profiling
    Kenzelmann, M
    Klären, R
    Hergenhahn, M
    Bonrouhi, M
    Gröne, HJ
    Schmid, W
    Schütz, G
    [J]. GENOMICS, 2004, 83 (04) : 550 - 558
  • [10] Polyadenylation of rRNA in Saccharomyces cerevisiae
    Kuai, L
    Fang, F
    Butler, JS
    Sherman, F
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (23) : 8581 - 8586