Chitosan-dosed adsorptive filter media for removal of formaldehyde from indoor air-Performance and cancer risk assessment

被引:10
作者
Shao, Wen-Cheng [1 ]
Wu, Haoyang [2 ]
Shiue, Angus [3 ]
Tseng, Chao-Heng [4 ]
Wang, Yu-Wen [4 ]
Hsu, Chen-Fu [4 ]
Leggett, Graham [5 ]
机构
[1] Natl Taipei Univ Technol, Dept Architecture, Taipei, Taiwan
[2] Univ Sci & Technol, Inst Adv Mat & Technol, Beijing, Peoples R China
[3] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei, Taiwan
[4] Natl Taipei Univ Technol, Inst Environm Engn & Management, Taipei, Taiwan
[5] LI COR Biosci, Cambridge, England
关键词
Formaldehyde; Chitosan; Inhibition; Filter; Risk;
D O I
10.1016/j.cplett.2021.138836
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
It is firmly established that contemporary building materials and indoor furnishings are associated with elevated concentrations of formaldehyde in indoor air, representing a hazard to human health. To mitigate this issue, formaldehyde and other pollutants in indoor air are removed via air conditioning systems fitted with appropriate filters. Based on positive results from earlier, relevant research, this study investigates the use of air conditioning filters treated with chitosan as potential eco-friendly absorbents for removal of formaldehyde, a significant indoor air pollutant. The filter is sprayed with different dosages of chitosan, in accordance with our previous work [8]. Removal rate and adsorption of formaldehyde are calculated for the health risk assessment. After twenty-four hours testing, the results showed the averaged concentration of formaldehyde is 1.146 ppm, 0.714 ppm, and 0.084 ppm with chitosan dosage of 2.6 mg m- 2, 5.3 mg m- 2, 8.0 mg m- 2, respectively. The averaged reduction of formaldehyde concentration is 64.9%, 80.0%, and 96.0%; the averaged absorption of chitosan on formaldehyde is 0.167 mg, 0.204 mg and 0.271 mg for chitosan dosage of 2.6 mg m- 2, 5.3 mg m- 2, 8.0 mg m- 2, respectively. The risk characterization figures without spaying chitosan are 2.94, 2.65 and 7.07 times higher when compared with the same figures associated with filters treated with 2.6 mg m- 2, 5.3 mg m- 2, and 8.0 mg m- 2 of chitosan. This study finds that chitosan has strong potential as a commercial adsorbent. Increasing the amount of chitosan applied to the filter substrate improves the efficacy of the absorbent and further reduces the indoor formaldehyde concentration and the associated carcinogenic risk.
引用
收藏
页数:7
相关论文
共 22 条
  • [1] [Anonymous], 2003, JAPANESE IND STANDAR
  • [2] [Anonymous], EXPOSURE FACTORS HDB
  • [3] Chiang C.C., 2007, MASTER DEP BIOENVIRO
  • [4] Application of chitosan, a natural aminopolysaccharide, for dye removal from aqueous solutions by adsorption processes using batch studies: A review of recent literature
    Crini, Gregorio
    Badot, Pierre-Marie
    [J]. PROGRESS IN POLYMER SCIENCE, 2008, 33 (04) : 399 - 447
  • [5] Risk Assessment of Indoor Formaldehyde and Other Carbonyls in Campus Environments in Northwestern China
    Ho, Steven Sai Hang
    Cheng, Yan
    Bai, Yi
    Ho, Kin Fai
    Dai, Wen Ting
    Cao, Jun Ji
    Lee, Shun Cheng
    Huang, Yu
    Ip, Ho Sai Simon
    Deng, Wen Jing
    Guo, Wei
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2016, 16 (08) : 1967 - 1980
  • [6] Sorption Efficiency of Chitosan Nanofibers toward Metal Ions at Low Concentrations
    Horzum, Nesrin
    Boyaci, Ezel
    Eroglu, Ahmet E.
    Shahwan, Talal
    Demir, Mustafa M.
    [J]. BIOMACROMOLECULES, 2010, 11 (12) : 3301 - 3308
  • [7] Health Risk Assessment of Inhalation Exposure to Formaldehyde and Benzene in Newly Remodeled Buildings, Beijing
    Huang, Lihui
    Mo, Jinhan
    Sundell, Jan
    Fan, Zhihua
    Zhang, Yinping
    [J]. PLOS ONE, 2013, 8 (11):
  • [8] Kim Ho-Hyun, 2011, Asian Journal of Atmospheric Environment, V5, P121
  • [9] Formaldehyde Exposure in Indoor Air From Public Places and Its Associated Health Risks in Kunshan City, China
    Liang, Xiaojun
    Zhang, Jianxin
    Song, Wenlei
    Wang, Kewei
    Zhang, Baoying
    [J]. ASIA-PACIFIC JOURNAL OF PUBLIC HEALTH, 2018, 30 (06) : 551 - 560
  • [10] Hollow latex particles functionalized with chitosan for the removal of formaldehyde from indoor air
    Nuasaen, Sukanya
    Opaprakasit, Pakorn
    Tangboriboonrat, Pramuan
    [J]. CARBOHYDRATE POLYMERS, 2014, 101 : 179 - 187