Analysis and detection of turn-to-turn short circuit fault in a permanent magnet Vernier generator based on modified winding function

被引:9
|
作者
Arianborna, MohammadHossein [1 ]
Faiz, Jawad [1 ]
Ghods, Mehrage [1 ]
Bazrafshan, Mohammad [1 ]
机构
[1] Univ Tehran, Sch Elect & Comp Engn, Coll Engn, Ctr Excellence Appl Electromagnet Syst, Tehran, Iran
关键词
linear machines; modified winding function generator; permanent magnet Vernier turn-turn short circuit fault; Vernier generator; SYNCHRONOUS MACHINE; MOTORS; PMSM; ECCENTRICITY;
D O I
10.1049/elp2.12127
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Operation of Vernier machines is based on flux modulation. They have some advantages including maintaining the rated torque in motor applications and the rated output power in generator applications at low speeds, high torque density and relatively low torque ripple due to their magnetic gear property and fault-tolerance. In recent years, the motor with various topologies has been developed for different applications. Therefore, analysing and monitoring different faults is essential in the design and implementation stages. This study has two main purposes. First, to introduce an accurate frequency index independent of load variations for detecting the turn-to-turn short circuit (TTSC) faults in the stator windings of a permanent magnet Vernier machine. Second, modelling the machine in a healthy condition and in the presence of TTSC faults to investigate its effect on machine performance and output characteristics. An analytical model is presented using the modified winding function theory under the TTSC fault by taking into account the effect of stator slots which enhances the accuracy of the air-gap permeance function estimation. In the process of calculating the fault index, frequency components of the output characteristics of the machine are obtained from the mathematical equations of the magnetic field. It is shown that the proposed indicators are robust against load variations.
引用
收藏
页码:1630 / 1647
页数:18
相关论文
共 50 条
  • [41] On-Line Detection of Coil Inter-Turn Short Circuit Faults in Dual-Redundancy Permanent Magnet Synchronous Motors
    Chen, Yiguang
    Chen, Xuemin
    Shen, Yonghuan
    ENERGIES, 2018, 11 (03):
  • [42] Characteristics Analysis of Field Winding Inter-Turn Short-Circuit Fault for Large-Capacity Synchronous Condenser Based on Stator Winding Asymmetric Branch Current
    Wang, Weihao
    Bian, Xu
    Huang, Hao
    Liang, Yanping
    IEEE ACCESS, 2023, 11 : 81930 - 81941
  • [43] Analysis and Detection of Inter-Turn Short-Circuit Fault Through Extended Self-Commissioning
    Qi, Yuan
    Zafarani, Mohsen
    Akin, Bilal
    Fedigan, Stephen E.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) : 2730 - 2739
  • [44] Inter-turn Short Fault Diagnosis of Permanent Magnet Synchronous Machines Using Negative Sequence Components
    Jeong, Hyeyun
    Moon, Seokbae
    Lee, Jewon
    Kim, Sang Woo
    PROCEEDINGS 2016 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2016, : 170 - 174
  • [45] Fault Detection of Stator Winding Interturn Short Circuit in PMSM based on Wavelet Packet Analysis
    Zheng An-Ping
    Yang Juan
    Wang Ling
    2013 FIFTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2013), 2013, : 566 - 569
  • [46] Data-Driven Inter-Turn Short Circuit Fault Detection in Induction Machines
    Xu, Zhao
    Hu, Changhua
    Yang, Feng
    Kuo, Shyh-Hao
    Goh, Chi-Keong
    Gupta, Amit
    Nadarajan, Sivakumar
    IEEE ACCESS, 2017, 5 : 25055 - 25068
  • [47] Mitigation of Interturn Short Circuit Fault Based on Axial Split Phase Permanent Magnet Synchronous Machine
    Geng, Lina
    Chai, Feng
    Pei, Yulong
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (04) : 2578 - 2587
  • [48] Inter-turn Fault Diagnosis of Permanent Magnet Synchronous Machine Based on Variational Mode Decomposition
    Li, Hao
    Hang, Jun
    Fang, Jie
    Zhang, Peng
    Ding, Shichuan
    Wang, Qunjing
    PROCEEDINGS OF THE 2018 13TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2018), 2018, : 2422 - 2425
  • [49] Stator winding short-circuit fault detection in a permanent magnet synchronous motor (PMSM) using negative sequence current in time domain
    Quiroga, Jabid E.
    INGENIERIA E INVESTIGACION, 2009, 29 (02): : 48 - 52
  • [50] Real-Time Detection of Incipient Inter-Turn Short Circuit and Sensor Faults in Permanent Magnet Synchronous Motor Drives Based on Generalized Likelihood Ratio Test and Structural Analysis
    Hasan Ebrahimi, Saeed
    Choux, Martin
    Huynh, Van Khang
    SENSORS, 2022, 22 (09)