Multi-site harmonization of 7 tesla MRI neuroimaging protocols

被引:32
作者
Clarke, William T. [1 ]
Mougin, Olivier [2 ]
Driver, Ian D. [3 ]
Rua, Catarina [4 ]
Morgan, Andrew T. [5 ]
Asghar, Michael [2 ]
Clare, Stuart [1 ]
Francis, Susan [2 ]
Wise, Richard G. [3 ]
Rodgers, Christopher T. [4 ]
Carpenter, Adrian [4 ]
Muir, Keith [5 ]
Bowtell, Richard [2 ]
机构
[1] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB, Wellcome Ctr Integrat Neuroimaging, Oxford, England
[2] Univ Nottingham, Sch Phys & Astron, Sir Peter Mansfield Imaging Ctr, Nottingham, England
[3] Cardiff Univ, Sch Psychol, Brain Res Imaging Ctr, Cardiff, Wales
[4] Univ Cambridge, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge, England
[5] Univ Glasgow, Imaging Ctr Excellence, Glasgow, Lanark, Scotland
基金
英国医学研究理事会; 英国惠康基金;
关键词
7; tesla; MRI; Harmonization; Anatomical; Functional; Scanner calibration; VISUAL ENVIRONMENT; HUMAN BRAIN; ROBUST; PULSE; INVERSION; CORTEX;
D O I
10.1016/j.neuroimage.2019.116335
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Increasing numbers of 7 T (7 T) magnetic resonance imaging (MRI) scanners are in research and clinical use. 7 T MRI can increase the scanning speed, spatial resolution and contrast-to-noise-ratio of many neuroimaging protocols, but technical challenges in implementation have been addressed in a variety of ways across sites. In order to facilitate multi-centre studies and ensure consistency of findings across sites, it is desirable that 7 T MRI sites implement common high-quality neuroimaging protocols that can accommodate different scanner models and software versions. With the installation of several new 7 T MRI scanners in the United Kingdom, the UK7T Network was established with an aim to create a set of harmonized structural and functional neuroimaging sequences and protocols. The Network currently includes five sites, which use three different scanner platforms, provided by two different vendors. Here we describe the harmonization of functional and anatomical imaging protocols across the three different scanner models, detailing the necessary changes to pulse sequences and reconstruction methods. The harmonized sequences are fully described, along with implementation details. Example datasets acquired from the same subject on all Network scanners are made available. Based on these data, an evaluation of the harmonization is provided. In addition, the implementation and validation of a common system calibration process is described.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Fast three-dimensional phase-unwrapping algorithm based on sorting by reliability following a non-continuous path
    Abdul-Rahman, H
    Gdeisat, M
    Burton, D
    Lalor, M
    [J]. OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION IV, PTS 1 AND 2, 2005, 5856 : 32 - 40
  • [2] A robust multi-scale approach to quantitative susceptibility mapping
    Acosta-Cabronero, Julio
    Milovic, Carlos
    Mattern, Hendrik
    Tejos, Cristian
    Speck, Oliver
    Callaghan, Martina F.
    [J]. NEUROIMAGE, 2018, 183 : 7 - 24
  • [3] How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    Andersson, JLR
    Skare, S
    Ashburner, J
    [J]. NEUROIMAGE, 2003, 20 (02) : 870 - 888
  • [4] [Anonymous], LAPACK USERS GUIDE
  • [5] [Anonymous], P INT SOC MAG RESON
  • [6] [Anonymous], P INT SOC MAG RESON
  • [7] [Anonymous], PS3ISO12052 NEMA ASS
  • [8] [Anonymous], ULTRAHIGH FIELD MRI
  • [9] [Anonymous], 2004, NeuroImage
  • [10] [Anonymous], 510 K PREM NOT MAGN