Molecularly imprinted coated graphene oxide solid-phase extraction monolithic capillary column for selective extraction and sensitive determination of phloxine B in coffee bean

被引:36
|
作者
Zhai, Haiyun [1 ]
Su, Zihao [1 ]
Chen, Zuanguang [2 ]
Liu, Zhenping [1 ]
Yuan, Kaisong [1 ]
Huang, Lu [1 ]
机构
[1] Guangdong Pharmaceut Univ, Coll Pharm, Guangzhou 510006, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Phloxine B; Graphene oxide-molecularly imprinted polymers; Solid-phase extraction; In situ polymerization; Monolithic capillary column; LIQUID-CHROMATOGRAPHY; POLYMER; URANINE; SAMPLES; WATER; MICROEXTRACTION; RECOGNITION; URINE;
D O I
10.1016/j.aca.2015.01.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to sensitively determine phloxine B in coffee bean by molecularly imprinted polymers (MIPs) coated graphene oxide (GO) solid-phase extraction (GO-MISPE) coupled with high-performance liquid chromatography and laser-induced fluorescence detection (HPLC-LIF). The GO-MISPE capillary monolithic column was prepared by water-bath in situ polymerization, using GO as supporting material, phloxine B, methacrylic acid (MAA), and ethylene dimethacrylate (EDMA) as template, functional monomer, and cross-linker, respectively. The properties of the homemade GO-MISPE capillary monolithic column, including capacity and specificity, were investigated under optimized conditions. The GO-MIPs were characterized by scanning electron microscopy (SEM) and Fourier transform-infrared spectroscopy (FT-IR). The mean recoveries of phloxine B in coffee bean ranged from 89.5% to 91.4% and the intra-day and inter-day relative standard deviation (RSD) values all ranged from 3.6% to 4.7%. Good linearity was obtained over 0.001-2.0 mg mL (1) (r = 0.9995) with the detection limit (S/N = 3) of 0.075 ng mL (1). Under the selected conditions, enrichment factors of over 90-fold were obtained and extraction on the monolithic column effectively cleaned up the coffee bean matrix. The results demonstrated that the proposed GO-MISPE HPLC-LIF method can be applied to sensitively determine phloxine B in coffee bean. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 21
页数:6
相关论文
共 50 条
  • [31] Molecularly Imprinted Solid-Phase Extraction for Selective Trace Analysis of Trifluoperazine
    Attaran, Abdol Mohammad
    Mohammadi, Narges
    Javanbakht, Mehran
    Akbari-Adergani, Behrouz
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (07) : 730 - 738
  • [32] Determination of trace bisphenol A in complex samples using selective molecularly imprinted solid-phase extraction coupled with capillary electrophoresis
    Mei, Surong
    Wu, Da
    Jiang, Ming
    Lu, Bin
    Lim, Jae-Min
    Zhou, Yi-Kai
    Lee, Yong-Ill
    MICROCHEMICAL JOURNAL, 2011, 98 (01) : 150 - 155
  • [33] Selective Determination of Melamine in Aqueous Medium by Molecularly Imprinted Solid Phase Extraction
    Curcio, Manuela
    Puoci, Francesco
    Cirillo, Giuseppe
    Iemma, Francesca
    Spizzirri, Umile Gianfranco
    Picci, Nevio
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2010, 58 (22) : 11883 - 11887
  • [34] Development of a molecularly imprinted solid-phase extraction sorbent for the selective extraction of telmisartan from human urine
    Yilmaz, Huma
    Basan, Hasan
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (08) : 1433 - 1439
  • [35] Molecularly imprinted solid-phase extraction for the selective determination of valnemulin in feeds with high performance liquid chromatography
    Guo, Hongbin
    Liu, Kaiyong
    Liu, Yahong
    Fang, Binghu
    Liu, Min
    He, Limin
    Zeng, Zhenling
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (02): : 181 - 185
  • [36] Magnetic Dummy Template Silica Sol-Gel Molecularly Imprinted Polymer Nanospheres as Magnetic Solid-Phase Extraction Material for the Selective and Sensitive Determination of Bisphenol A in Plastic Bottled Beverages
    Chang, Tingting
    Yan, Xiangyang
    Liu, Shaomin
    Liu, Yuxin
    FOOD ANALYTICAL METHODS, 2017, 10 (12) : 3980 - 3990
  • [37] Assessment of Molecularly Imprinted Polymers as Selective Solid-Phase Extraction Sorbents for the Detection of Cloxacillin in Drinking and River Water
    Garcinuno, Rosa Ma
    Collado, Eduardo Jose
    Paniagua, Gema
    Bravo, Juan Carlos
    Fernandez Hernando, Pilar
    POLYMERS, 2023, 15 (21)
  • [38] Chip-based molecularly imprinted monolithic capillary array columns coated GO/SiO2 for selective extraction and sensitive determination of rhodamine B in chili powder
    Zhai, Haiyun
    Huang, Lu
    Chen, Zuanguang
    Su, Zihao
    Yuan, Kaisong
    Liang, Guohuan
    Pan, Yufang
    FOOD CHEMISTRY, 2017, 214 : 664 - 669
  • [39] Molecularly imprinted solid-phase extraction for chlorpyrifos determination in water samples
    Liu, Jun
    Yang, Ming
    Huai, Lu Feng
    ENVIRONMENT MATERIALS AND ENVIRONMENT MANAGEMENT PTS 1-3, 2010, 113-116 : 947 - 951
  • [40] Molecularly imprinted solid-phase extraction for cholesterol determination in cheese products
    Puoci, F.
    Curcio, M.
    Cirillo, G.
    Iemma, F.
    Spizzirri, U. G.
    Picci, N.
    FOOD CHEMISTRY, 2008, 106 (02) : 836 - 842