Amperometric determination of hydrogen peroxide by direct and catalytic reduction at a copper electrode

被引:88
|
作者
Somasundrum, M
Kirtikara, K
Tanticharoen, M
机构
[1] KING MONGKUTS INST TECHNOL,SCH ELECT ENGN,BANGKOK 10140,THAILAND
[2] NATL CTR GENET ENGN & BIOTECHNOL,BANGKOK 10400,THAILAND
关键词
amperometry; catalytic methods; hydrogen peroxide;
D O I
10.1016/0003-2670(95)00473-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In a buffer solution at ambient temperature and dissolved oxygen concentration, pH 6.7, copper electrodes could be cycled between the Cu(O)/Cu(II) redox states, by cycling the potential between -0.8 and + 0.3 V vs. SCE. At 1 V s(-1), the reduction of Cu(II) proceeded with a rate constant of 12.3 s(-1) (alpha(C) = 0.16, alpha(A) = 0.93). The redox couple catalysed the reduction of hydrogen peroxide, with a second-order rate constant of approx. 25 +/- 10 M(-1) s(-1). Amperometric determination of H2O2 at - 0.25 V gave a limit of detection (2 X noise) of 1.2 mu M (sensitivity = 0.211 mA mM(-1) cm(-2) up to 2.0 mM), with a response time (steady-state) of 3 to 4 s. A 1 mu M change in the O-2 concentration gave approx. a 0.04% change in the H2O2 sensitivity. The presence of H2O-soluble copper-complexing anions at low concentrations gave a change in the H2O2 response. At higher anion concentrations (>20 mM), the rate of electron transfer from the metal was faster than the rate of Cu(II) dissolution. A copper micro-band electrode was used to determine H2O2 in a mixture of glacial acetic acid and chloroform.
引用
收藏
页码:59 / 70
页数:12
相关论文
共 50 条
  • [41] An amperometric xanthine oxidase enzyme electrode based on hydrogen peroxide electroreduction
    Dimcheva, N
    Horozova, E
    Jordanova, Z
    ZEITSCHRIFT FUR NATURFORSCHUNG C-A JOURNAL OF BIOSCIENCES, 2002, 57 (9-10): : 883 - 889
  • [42] Amperometric determination of thiourea in alkaline media on a copper oxide–copper electrode
    F. Manea
    C. Radovan
    J. Schoonman
    Journal of Applied Electrochemistry, 2006, 36 : 1075 - 1081
  • [43] Fabrication of cuprous sulfide nanorods supported on copper foam for nonenzymatic amperometric determination of glucose and hydrogen peroxide
    Lu, Wangdong
    Sun, Yujing
    Dai, Haichao
    Ni, Pengjuan
    Jiang, Shu
    Wang, Yilin
    Li, Zhen
    Li, Zhuang
    RSC ADVANCES, 2016, 6 (93): : 90732 - 90738
  • [44] A new amperometric nanostructured sensor for the analytical determination of hydrogen peroxide
    Guascito, M. R.
    Filippo, E.
    Malitesta, C.
    Manno, D.
    Serra, A.
    Turco, A.
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (04): : 1057 - 1063
  • [45] Study on catalytic kinetic spectrophotometric determination of trace copper with hydrogen peroxide and safranine O
    Zhuang, Hui-Rong
    Yejin Fenxi/Metallurgical Analysis, 2004, 24 (04):
  • [46] Flow injection amperometric determination of hydrogen peroxide in household commercial products with a ruthenium oxide hexacyanoferrate modified electrode
    Roselyn C. Peña
    Juan C. M. Gamboa
    Thiago R. L. C. Paixão
    Mauro Bertotti
    Microchimica Acta, 2009, 166 : 277 - 281
  • [47] EXALTATION OF THE LIMITING CURRENT OF OXYGEN BY HYDROGEN PEROXIDE AT THE ROTATED GOLD ELECTRODE AS A MEANS FOR AMPEROMETRIC DETERMINATION OF TRACES OF OXYGEN
    KOLTHOFF, IM
    JORDAN, J
    ANALYTICAL CHEMISTRY, 1952, 24 (06) : 1071 - 1072
  • [48] Flow injection amperometric determination of hydrogen peroxide in household commercial products with a ruthenium oxide hexacyanoferrate modified electrode
    Pena, Roselyn C.
    Gamboa, Juan C. M.
    Paixao, Thiago R. L. C.
    Bertotti, Mauro
    MICROCHIMICA ACTA, 2009, 166 (3-4) : 277 - 281
  • [49] Amperometric determination of thiourea in alkaline media on a copper oxide-copper electrode
    Manea, F.
    Radovan, C.
    Schoonman, J.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2006, 36 (10) : 1075 - 1081
  • [50] Application of pyrite and chalcopyrite as sensor electrode for amperometric detection and measurement of hydrogen peroxide
    Wang, Y.
    Zhao, K. J.
    Tao, D. P.
    Zhai, F. G.
    Yang, H. B.
    Zhang, Z. Q.
    RSC ADVANCES, 2018, 8 (09): : 5013 - 5019