Underwater computational ghost imaging

被引:107
作者
Le, Mingnan [1 ,2 ]
Wang, Gao [1 ,2 ]
Zheng, Huabin [1 ,2 ]
Liu, Jianbin [1 ,2 ]
Zhou, Yu [3 ]
Xu, Zhuo [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, Minist Educ, Key Lab, Elect Mat Res Lab, Xian 710049, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Int Ctr Dielect Res, Xian 710049, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, Dept Appl Phys, MOE Key Lab Nonequilibrium Synth & Modulat Conden, Xian 710049, Shaanxi, Peoples R China
来源
OPTICS EXPRESS | 2017年 / 25卷 / 19期
关键词
D O I
10.1364/OE.25.022859
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Since the quality of underwater classical optical imaging is constrained by the absorptive and scattering nature for underwater environment, it is a challenging task to obtain long distance imaging. Ghost imaging is a second-order correlation imaging method using coincidence measurement, which has the advantages of disturbance-free and wider angle of view (AOV), which can effectively improve the imaging result. We have investigated the computational ghost imaging under the underwater conditions for different turbidities and from different angles. The reconstruction obtained by computational ghost imaging can be rather desirable, in the scenarios that the classical optical imaging method completely fails. Moreover, the underwater computational ghost imaging can bear a wide range of AOV, where the obtained imaging results can be satisfiable in regardless of the detector's locations. This result brings a better alternative for underwater optical imaging. (C) 2017 Optical Society of America
引用
收藏
页码:22859 / 22868
页数:10
相关论文
共 34 条
  • [1] Alejandra Valencia, 2005, PHYS REV LETT, V94
  • [2] Ghost imaging using homodyne detection
    Bache, M
    Brambilla, E
    Gatti, A
    Lugiato, LA
    [J]. PHYSICAL REVIEW A, 2004, 70 (02): : 023823 - 1
  • [3] Experiment in lensless ghost imaging with thermal light
    Basano, Lorenzo
    Ottonello, Pasquale
    [J]. APPLIED PHYSICS LETTERS, 2006, 89 (09)
  • [4] A conceptual experiment on single-beam coincidence detection with pseudothermal light
    Basano, Lorenzo
    Ottonello, Pasquale
    [J]. OPTICS EXPRESS, 2007, 15 (19): : 12386 - 12394
  • [5] Two-photon coincidence imaging with a classical source
    Bennink, RS
    Bentley, SJ
    Boyd, RW
    [J]. PHYSICAL REVIEW LETTERS, 2002, 89 (11)
  • [6] Bennink RS, 2004, PHYS REV LETT, V92, DOI 10.1103/PhysRevLett.92.069901
  • [7] Bina M., 2012, PHYS REV LETT, V110, P1
  • [8] Ghost imaging with a single detector
    Bromberg, Yaron
    Katz, Ori
    Silberberg, Yaron
    [J]. PHYSICAL REVIEW A, 2009, 79 (05):
  • [9] Cai Y., 2005, PHYS REV E, V71, P122
  • [10] Optimization of thermal ghost imaging: high-order correlations vs. background subtraction
    Chan, Kam Wai C.
    O'Sullivan, Malcolm N.
    Boyd, Robert W.
    [J]. OPTICS EXPRESS, 2010, 18 (06): : 5562 - 5573