A prospective randomized trial comparing contrast-enhanced targeted versus systematic ultrasound guided biopsies: Impact on prostate cancer detection

被引:62
|
作者
Mitterberger, Michael
Horninger, Wolfgang
Pelzer, Alexandre
Strasser, Hannes
Bartsch, Georg
Moser, Patrizia
Halpern, Ethan J.
Gradl, Johann
Aigner, Friedrich
Pallwein, Leo
Frauscher, Ferdinand
机构
[1] Med Univ Innsbruck, Dept Urol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Radiat 2, Innsbruck, Austria
[3] Med Univ Innsbruck, Dept Pathol, Innsbruck, Austria
[4] Thomas Jefferson Univ, Div Diagnost Ultrasound, Philadelphia, PA USA
关键词
prostate cancer; ultrasound; contrast-enhanced ultrasound; prostate biopsy;
D O I
10.1002/pros.20639
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: We performed a prospective randomized trial comparing 5 contrast-enhanced color Doppler (CECD) ultrasound (US) targeted biopsy cores to 10 gray-scale US guided systematic biopsy (SB) cores to determine the impact on the cancer detection rate. METHODS:. We prospectively randomized 100 prostate specific antigen (PSA) screening volunteers with an elevated PSA (>= 1.25 ng/ml and free-to-total PSA < 18%) to undergo contrast-enhanced targeted or SB. Contrast-enhanced targeted biopsies with a limited number of five cores were performed into hypervascular areas of the peripheral zone (PZ) during administration of the US contrast agent SonoVue (R) (Bracco, Italy). A subjective grading of the vascularity from 0 to 3 was used: grade 0, no color signal; 1, low density; 2, medium density; and 3, high density of color signals. Ten SBs were obtained in a standard spatial distribution. Cancer detection rates were compared in the groups. RESULTS: Cancer was detected in 16/50 subjects (32%) by targeted biopsy, and in 13/50 patients (26%) with SB. The cancer detection rate was significantly better for the targeted approach (P < 0.04, McNemar). The detection rate for targeted biopsy cores (15.6% or 39/250 cores) was significantly better than for SB cores (6.8% or 34/500 cores, P < 0.001, McNemar). CONCLUSIONS:. CECD targeted biopsy detected more cancers than SB with a reduced number of biopsy cores.
引用
收藏
页码:1537 / 1542
页数:6
相关论文
共 50 条
  • [21] Diagnostic accuracy of qualitative and quantitative magnetic resonance imaging-guided contrast-enhanced ultrasound (MRI-guided CEUS) for the detection of prostate cancer: a prospective and multicenter study
    Yunyun Liu
    Dianyuan Lu
    Guang Xu
    Shuai Wang
    Bangguo Zhou
    Ying Zhang
    Beibei Ye
    Lihua Xiang
    Yifeng Zhang
    Huixiong Xu
    La radiologia medica, 2024, 129 : 585 - 597
  • [22] Multiparametric dynamic contrast-enhanced ultrasound imaging of prostate cancer
    Wildeboer, Rogier R.
    Postema, Arnoud W.
    Demi, Libertario
    Kuenen, Maarten P. J.
    Wijkstra, Hessel
    Mischi, Massimo
    EUROPEAN RADIOLOGY, 2017, 27 (08) : 3226 - 3234
  • [23] Multiparametric dynamic contrast-enhanced ultrasound imaging of prostate cancer
    Rogier R. Wildeboer
    Arnoud W. Postema
    Libertario Demi
    Maarten P. J. Kuenen
    Hessel Wijkstra
    Massimo Mischi
    European Radiology, 2017, 27 : 3226 - 3234
  • [24] Contrast-enhanced ultrasound versus conventional ultrasound in guided liver puncture biopsy: a systematic review and meta-analysis
    Yang, Lidan
    Zhang, Ting
    Wang, Lei
    Du, Juan
    Zhang, Hao
    Yi, Wenquan
    MEDICAL ULTRASONOGRAPHY, 2024, 26 (03) : 301 - 309
  • [25] A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer
    Stijn W. T. P. J. Heijmink
    Hilco van Moerkerk
    Lambertus A. L. M. Kiemeney
    J. Alfred Witjes
    Ferdinand Frauscher
    Jelle O. Barentsz
    European Radiology, 2006, 16 : 927 - 938
  • [26] The prostate cancer detection rates of CEUS-targeted versus MRI-targeted versus systematic TRUS-guided biopsies in biopsy-naïve men: a prospective, comparative clinical trial using the same patients
    A. W. Postema
    M. J. V. Scheltema
    C. K. Mannaerts
    R. J. G. Van Sloun
    T. Idzenga
    M. Mischi
    M. R. E. Engelbrecht
    J. J. M. C. H. De la Rosette
    H. Wijkstra
    BMC Urology, 17
  • [27] A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer
    Heijmink, SWTPJ
    van Moerkerk, H
    Kiemeney, LALM
    Witjes, JA
    Frauscher, F
    Barentsz, JO
    EUROPEAN RADIOLOGY, 2006, 16 (04) : 927 - 938
  • [28] Prostate cancer: Contrast-enhanced US for detection
    Halpern, EJ
    Rosenberg, M
    Gomella, LG
    RADIOLOGY, 2001, 219 (01) : 219 - 225
  • [29] Contrast-enhanced ultrasound-guided musculoskeletal biopsies: our experience and technique
    Steven P. Daniels
    Lori Mankowski Gettle
    Donna G. Blankenbaker
    Kenneth S. Lee
    Andrew B. Ross
    Skeletal Radiology, 2021, 50 : 673 - 681
  • [30] Contrast-enhanced ultrasound-guided musculoskeletal biopsies: our experience and technique
    Daniels, Steven P.
    Mankowski Gettle, Lori
    Blankenbaker, Donna G.
    Lee, Kenneth S.
    Ross, Andrew B.
    SKELETAL RADIOLOGY, 2021, 50 (04) : 673 - 681