A High-Frequency Annular-Array Transducer Using an Interdigital Bonded 1-3 Composite

被引:32
作者
Chabok, Hamid Reza [1 ]
Cannata, Jonathan M. [1 ]
Kim, Hyung Ham [1 ]
Williams, Jay A. [1 ]
Park, Jinhyoung [1 ]
Shung, K. Kirk [1 ]
机构
[1] Univ So Calif, Dept Biomed Engn, NIH Resource Ctr Med Ultrason Transducer Technol, Los Angeles, CA 90089 USA
关键词
ULTRASOUND TRANSDUCERS; FABRICATION; DESIGN; PULSE;
D O I
10.1109/TUFFC.2011.1787
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper reports the design, fabrication, and characterization of a 1-3 composite annular-array transducer. An interdigital bonded (IB) 1-3 composite was prepared using two IB operations on a fine-grain piezoelectric ceramic. The final composite had 19-mu m-wide posts separated by 6-mu m-wide polymer kerfs. A novel method to remove metal electrodes from polymer portions of the 1-3 composite was established to eliminate the need for patterning and aligning the electrode on the composite to the electrodes on a flexible circuit. Unloaded epoxy was used for both the matching and backing layers and a flexible circuit was used for interconnect. A prototype array was successfully fabricated and tested. The results were in reasonable agreement with those predicted by a circuit-analogous model. The average center frequency estimated from the measured pulse-echo responses of array elements was 33.5 MHz and the -6-dB fractional bandwidth was 57%. The average insertion loss recorded was 14.3 dB, and the maximum crosstalk between the nearest-neighbor elements was less than -37 dB. Images of a wire phantom and excised porcine eye were obtained to show the capabilities of the array for high-frequency ultrasound imaging.
引用
收藏
页码:206 / 214
页数:9
相关论文
共 31 条
[1]   TRANSIENT FIELDS OF CONCAVE ANNULAR ARRAYS [J].
ARDITI, M ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1981, 3 (01) :37-61
[2]   Design and fabrication of annular arrays for high-frequency ultrasound [J].
Brown, JA ;
Démoré, CEM ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (08) :1010-1017
[3]  
Cochran S, 2004, ULTRASON, P1682
[4]   Advances in ultrasound biomicroscopy [J].
Foster, FS ;
Pavlin, CJ ;
Harasiewicz, KA ;
Christopher, DA ;
Turnbull, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (01) :1-27
[5]  
GENG X, 1999, J APPL PHYS, V85, P1
[6]  
Gottlieb E. J., 2005, THESIS U SO CALIFORN
[7]   Development of a high-frequency (> 50 MHz) copolymer annular-array, ultrasound transducer [J].
Gottlieb, EJ ;
Cannata, JM ;
Hu, CH ;
Shung, KK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) :1037-1045
[8]  
Guess JF, 1995, ULTRASON, P1279, DOI 10.1109/ULTSYM.1995.495790
[9]  
Hirata Y, 1997, 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, P877, DOI 10.1109/ULTSYM.1997.661721
[10]   Coded excitation using biphase-coded pulse with mismatched filters for high-frequency ultrasound imaging [J].
Hu, Chang-Hong ;
Liu, Ruibin ;
Zhou, Qifa ;
Yen, Jesse ;
Shung, K. Kirk .
ULTRASONICS, 2006, 44 (03) :330-336