Reduction of streak artifacts caused by low photon counts utilizing an image-based forward projection in computed tomography

被引:6
|
作者
Niwa, Shinji [1 ,2 ]
Ichikawa, Katsuhiro [3 ]
Kawashima, Hiroki [3 ]
Takata, Tadanori [4 ]
Minami, Shuhei [4 ]
Mitsui, Wataru [4 ]
机构
[1] Nakatsugawa Municipal Gen Hosp, Dept Med Technol, 1522-1 Komanba, Gifu 5080011, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Kanazawa Univ Hosp, Radiol Div, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
关键词
Computed tomography; Streak artifact; Radiation dose; Sinogram; Spatial resolution; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; CT; QUALITY; RESOLUTION; ALGORITHM;
D O I
10.1016/j.compbiomed.2021.104583
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The streak artifacts in computed tomography (CT) images caused by low photon counts are known to be effectively suppressed by raw-data-based techniques. This study aims to propose a technique to reduce the streak artifact without accessing the raw data. Methods: The proposed streak artifact reduction (SAR) technique consists of three steps: numerical forward projection to a CT image, adaptive filtering of the generated sinogram, and image reconstruction from the processed sinogram. The authors have expanded the two-dimensional method (2D-SAR) to three dimensions (3DSAR) by using consecutive CT images. The modulation transfer function (MTF), the image noise (standard deviation), and the visibility of comb-shaped objects were evaluated at a low dose of 5 mGy. Using anthropomorphic abdominal and chest phantoms, CT images and the artifact index (AI) were compared between 3D-SAR and two types of iterative reconstruction (IR). Results: Sufficient artifact reductions associated with 54% and 61% reduction of noise for 2D- and 3D-SAR, respectively, were obtained in the phantom images, although the 50%MTF decreased by 28%. The visibility of the combs was improved with both the 2D- and 3D-SAR methods. The AI results of 3D-SAR were better than one type of IR and almost equal to the other type of IR, which was consistent with observed artifacts. Conclusion: Both 2D-SAR and 3D-SAR have turned out to be effective in reducing streak artifacts. The proposed technique will be an effective tool since it needs no raw data, and thus can be applied to any CT images produced by a wide variety of CT systems.
引用
收藏
页数:13
相关论文
共 20 条
  • [11] Image-Based Noise Reduction for Material Decomposition in Dual or Multi Energy Computed Tomography
    Ozdemir, Mahmut
    Dorn, Sabrina
    Pisana, Francesco
    Uhrig, Monika
    Schlemmer, Heinz-Peter
    Kachelriess, Marc
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [12] A pseudo-discrete algebraic reconstruction technique (PDART) prior image-based suppression of high density artifacts in computed tomography
    Pua, Rizza
    Park, Miran
    Wi, Sunhee
    Cho, Seungryong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 840 : 42 - 50
  • [13] An Image-Based Prior Knowledge-Free Approach for a Multi-Material Decomposition in Photon-Counting Computed Tomography
    Neumann, Jonas
    Nowak, Tristan
    Schmidt, Bernhard
    von Zanthier, Joachim
    DIAGNOSTICS, 2024, 14 (12)
  • [14] Raw-data-based iterative reconstruction versus filtered back projection: image quality of low-dose chest computed tomography examinations in 87 patients
    Wang, Haiyan
    Tan, Bingyi
    Zhao, Bin
    Liang, Changhu
    Xu, Zhuodong
    CLINICAL IMAGING, 2013, 37 (06) : 1024 - 1032
  • [15] Single-Photon Emission Computed Tomography/Computed Tomography Image-Based Radiomics for Discriminating Vertebral Bone Metastases From Benign Bone Lesions in Patients With Tumors
    Jin, Zhicheng
    Zhang, Fang
    Wang, Yizhen
    Tian, Aijuan
    Zhang, Jianan
    Chen, Meiyan
    Yu, Jing
    FRONTIERS IN MEDICINE, 2022, 8
  • [16] Radiation dose reduction using deep learning-based image reconstruction for a low-dose chest computed tomography protocol: a phantom study
    Jung, Yunsub
    Hur, Jin
    Han, Kyunghwa
    Imai, Yasuhiro
    Hong, Yoo Jin
    Im, Dong Jin
    Lee, Kye Ho
    Desnoyers, Melissa
    Thomsen, Brian
    Shigemasa, Risa
    Um, Kyounga
    Jang, Kyungeun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1937 - +
  • [17] Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours
    Amthauer, H
    Denecke, T
    Rohlfing, T
    Ruf, J
    Böhmig, M
    Gutberlet, M
    Plöckinger, U
    Felix, R
    Lemke, AJ
    EUROPEAN RADIOLOGY, 2005, 15 (07) : 1456 - 1462
  • [18] Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours
    H. Amthauer
    T. Denecke
    T. Rohlfing
    J. Ruf
    M. Böhmig
    M. Gutberlet
    U. Plöckinger
    R. Felix
    A. J. Lemke
    European Radiology, 2005, 15 : 1456 - 1462
  • [19] Image Comparative Assessment Using Iterative Reconstructions Clinical Comparison of Low-Dose Abdominal/Pelvic Computed Tomography Between Adaptive Statistical, Model-Based Iterative Reconstructions and Traditional Filtered Back Projection in 65 Patients
    Vardhanabhuti, Varut
    Riordan, Richard D.
    Mitchell, Grant R.
    Hyde, Christopher
    Roobottom, Carl A.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (04) : 209 - 216
  • [20] Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction
    Nakamoto, Atsushi
    Kim, Tonsok
    Hori, Masatoshi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Sakane, Makoto
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1715 - 1723