Reduction of streak artifacts caused by low photon counts utilizing an image-based forward projection in computed tomography

被引:6
|
作者
Niwa, Shinji [1 ,2 ]
Ichikawa, Katsuhiro [3 ]
Kawashima, Hiroki [3 ]
Takata, Tadanori [4 ]
Minami, Shuhei [4 ]
Mitsui, Wataru [4 ]
机构
[1] Nakatsugawa Municipal Gen Hosp, Dept Med Technol, 1522-1 Komanba, Gifu 5080011, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Kanazawa Univ Hosp, Radiol Div, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
关键词
Computed tomography; Streak artifact; Radiation dose; Sinogram; Spatial resolution; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; CT; QUALITY; RESOLUTION; ALGORITHM;
D O I
10.1016/j.compbiomed.2021.104583
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The streak artifacts in computed tomography (CT) images caused by low photon counts are known to be effectively suppressed by raw-data-based techniques. This study aims to propose a technique to reduce the streak artifact without accessing the raw data. Methods: The proposed streak artifact reduction (SAR) technique consists of three steps: numerical forward projection to a CT image, adaptive filtering of the generated sinogram, and image reconstruction from the processed sinogram. The authors have expanded the two-dimensional method (2D-SAR) to three dimensions (3DSAR) by using consecutive CT images. The modulation transfer function (MTF), the image noise (standard deviation), and the visibility of comb-shaped objects were evaluated at a low dose of 5 mGy. Using anthropomorphic abdominal and chest phantoms, CT images and the artifact index (AI) were compared between 3D-SAR and two types of iterative reconstruction (IR). Results: Sufficient artifact reductions associated with 54% and 61% reduction of noise for 2D- and 3D-SAR, respectively, were obtained in the phantom images, although the 50%MTF decreased by 28%. The visibility of the combs was improved with both the 2D- and 3D-SAR methods. The AI results of 3D-SAR were better than one type of IR and almost equal to the other type of IR, which was consistent with observed artifacts. Conclusion: Both 2D-SAR and 3D-SAR have turned out to be effective in reducing streak artifacts. The proposed technique will be an effective tool since it needs no raw data, and thus can be applied to any CT images produced by a wide variety of CT systems.
引用
收藏
页数:13
相关论文
共 20 条
  • [1] An image-based metal artifact reduction technique utilizing forward projection in computed tomography
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    Takata, Tadanori
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 402 - 411
  • [2] An Image-Based Reduction of Metal Artifacts in Computed Tomography
    Pua, Rizza
    Wi, Sunhee
    Park, Miran
    Lee, Jung-Ryun
    Cho, Seungryong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 131 - 141
  • [3] Image-based iterative compensation of motion artifacts in computed tomography
    Schrettera, Colas
    Rose, Georg
    Bertram, Matthias
    MEDICAL PHYSICS, 2009, 36 (11) : 5323 - 5330
  • [4] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Luzhbin, Dmytro
    Wu, Jay
    JOURNAL OF DIGITAL IMAGING, 2020, 33 (01) : 71 - 82
  • [5] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Dmytro Luzhbin
    Jay Wu
    Journal of Digital Imaging, 2020, 33 : 71 - 82
  • [6] Image-based Metal Artifact Reduction in X-ray Computed Tomography utilizing Local Anatomical Similarity
    Dong, Xue
    Yang, Xiaofeng
    Rosenfield, Jonathan
    Elder, Eric
    Dhabaan, Anees
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [7] Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
    Watanabe, Shota
    Ichikawa, Katsuhiro
    Kawashima, Hiroki
    Kono, Yuki
    Kosaka, Hiroyuki
    Yamada, Koji
    Ishii, Kazunari
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 100 - 108
  • [8] Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography
    Michalek, Jan
    MICROSCOPY AND MICROANALYSIS, 2015, 21 (06) : 1602 - 1615
  • [9] A novel forward projection-based metal artifact reduction method for flat-detector computed tomography
    Prell, Daniel
    Kyriakou, Yiannis
    Beister, Marcel
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21) : 6575 - 6591
  • [10] Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography
    Chang, Chia-Hao
    Wu, Hsiang-Ning
    Hsu, Ching-Han
    Lin, Hsin-Hon
    PLOS ONE, 2023, 18 (03):