Local catheter impedance drop during pulmonary vein isolation predicts acute conduction block in patients with paroxysmal atrial fibrillation: initial results of the LOCALIZE clinical trial

被引:51
|
作者
Das, Moloy [1 ]
Luik, Armin [2 ]
Shepherd, Ewen [1 ]
Sulkin, Matthew [3 ]
Laughner, Jacob [3 ]
Oesterlein, Tobias [3 ]
Duffy, Elizabeth [3 ]
Meyer, Christian [4 ]
Jais, Pierre [5 ]
Duchateau, Josselin [5 ]
Yue, Arthur [6 ]
Ullah, Waqas [6 ]
Ramos, Pablo [7 ,8 ]
Garcia-Bolao, Ignacio [7 ,8 ]
机构
[1] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[2] Univ Freiburg, Acad Teaching Hosp, Stadt Klinikum Karlsruhe, Med Klin 4, Karlsruhe, Germany
[3] Boston Sci Corp, Electrophysiol Dept, St Paul, MN USA
[4] Univ Hosp Hamburg, Univ Heart Ctr, Dept Cardiol, Hamburg, Germany
[5] Univ Bordeaux, CHU Bordeaux, Hop Cardiol Haut Leveque, Inst Rythmol & Modelisat Cardiaque LIRYC, Bordeaux, France
[6] Univ Hosp Southampton, Dept Cardiol, Southampton, Hants, England
[7] Clin Univ Navarra, Dept Cardiol & Cardiovasc Surg, Pamplona, Spain
[8] Navarra Inst Hlth Res, IdiSNA, Navarra, Spain
来源
EUROPACE | 2021年 / 23卷 / 07期
关键词
Radiofrequency ablation; Local impedance; Atrial fibrillation; Pulmonary vein isolation; ABLATION; RECONNECTION; FORCE;
D O I
10.1093/europace/euab004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Radiofrequency ablation creates irreversible cardiac damage through resistive heating and this temperature change results in a generator impedance drop. Evaluation of a novel local impedance (LI) technology measured exclusively at the tip of the ablation catheter found that larger LI drops were indicative of more effective lesion formation. We aimed to evaluate whether LI drop is associated with conduction block in patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI). Methods and results Sixty patients underwent LI-blinded de novo PVI using a point-by-point ablation workflow. Pulmonary vein rings were divided into 16 anatomical segments. After a 20-min waiting period, gaps were identified on electroanatomic maps. Median LI drop within segments with inter-lesion distance <= 6 mm was calculated offline. The diagnostic accuracy of LI drop for predicting segment block was assessed using receiver operating characteristic analysis. For segments with inter-lesion distance <= 6 mm, acutely blocked segments had a significantly larger LI drop [19.8 (14.1-27.1) Omega] compared with segments with gaps [10.6 (7.8-14.7) Omega, P < 0.001). In view of left atrial wall thickness differences, the association between LI drop and block was further evaluated for anterior/roof and posterior/inferior segments. The optimal LI cut-off value for anterior/roof segments was 16.1 Omega (positive predictive value for block: 96.3%) and for posterior/inferior segments was 12.3 Omega (positive predictive value for block 98.1%) where inter-lesion distances were <= 6 mm. Conclusion The magnitude of LI drop was predictive of acute PVI segment conduction block in patients with paroxysmal AF. The thinner posterior wall required smaller LI drops for block compared with the thicker anterior wall.
引用
收藏
页码:1042 / 1051
页数:10
相关论文
共 50 条
  • [41] Acute efficacy of contiguous versus temporally discontiguous point-by-point radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a randomized study
    Aldhoon, Bashar
    Peichl, Petr
    Osmancik, Pavel
    Konecny, Petr
    Kautzner, Josef
    Wichterle, Dan
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (03) : 661 - 667
  • [42] Inducibility of atrial tachyarrhythmias after circumferential pulmonary vein isolation in patients with paroxysmal atrial fibrillation:: clinical predictor and outcome during follow-up
    Satomi, Kazuhiro
    Tilz, Roland
    Takatsuki, Seiji
    Chun, Julian
    Schmidt, Boris
    Baensch, Dietmar
    Antz, Matthias
    Zerm, Thomas
    Metzner, Andreas
    Koektuerk, Buelent
    Ernst, Sabine
    Greten, Heiner
    Kuck, Karl-Heinz
    Ouyang, Feifan
    EUROPACE, 2008, 10 (08): : 949 - 954
  • [43] Long-term clinical outcome of extensive pulmonary vein isolation-based catheter ablation therapy in patients with paroxysmal and persistent atrial fibrillation
    Miyazaki, Shinsuke
    Kuwahara, Taishi
    Kobori, Atsushi
    Takahashi, Yoshihide
    Takei, Asumi
    Sato, Akira
    Isobe, Mitsuaki
    Takahashi, Atsushi
    HEART, 2011, 97 (08) : 668 - 673
  • [44] Vagal response during circumferential pulmonary vein isolation decreases the recurrence of atrial fibrillation in the short-term in patients with paroxysmal atrial fibrillation: A prospective, observational study
    Fang, Ping
    Wang, Jinfeng
    Wei, Youquan
    Wang, Xianghai
    Yang, Hao
    Zhang, Meijun
    JOURNAL OF ELECTROCARDIOLOGY, 2021, 69 : 145 - 150
  • [45] Use of a multi-electrode radiofrequency balloon catheter to achieve pulmonary vein isolation in patients with paroxysmal atrial fibrillation: 12-Month outcomes of the RADIANCE study
    Dhillon, Gurpreet Singh
    Honarbakhsh, Shohreh
    Di Monaco, Antonio
    Coling, Ann Elizabeth
    Lenka, Kernerova
    Pizzamiglio, Francesca
    Hunter, Ross J.
    Horton, Rodney
    Mansour, Moussa
    Natale, Andrea
    Reddy, Vivek
    Grimaldi, Massimo
    Neuzil, Petr
    Tondo, Claudio
    Schilling, Richard J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1259 - 1269
  • [46] Redefining the Blanking Period After Catheter Ablation for Paroxysmal Atrial Fibrillation Insights From the ADVICE (Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination) Trial
    Willems, Stephan
    Khairy, Paul
    Andrade, Jason G.
    Hoffmann, Boris A.
    Levesque, Sylvie
    Verma, Atul
    Weerasooriya, Rukshen
    Novak, Paul
    Arentz, Thomas
    Deisenhofer, Isabel
    Rostock, Thomas
    Steven, Daniel
    Rivard, Lena
    Guerra, Peter G.
    Dyrda, Katia
    Mondesert, Blandine
    Dubuc, Marc
    Thibault, Bernard
    Talajic, Mario
    Roy, Denis
    Nattel, Stanley
    Macle, Laurent
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (08)
  • [47] Individualized or fixed approach to pulmonary vein isolation utilizing the fourth-generation cryoballoon in patients with paroxysmal atrial fibrillation: the randomized INDI-FREEZE trial
    Heeger, Christian-Hendrik
    Popescu, Sorin Stefan
    Saraei, Roza
    Kirstein, Bettina
    Hatahet, Sascha
    Samara, Omar
    Traub, Anna
    Fehe, Marcel
    D'Ambrosio, Gabriele
    Keelani, Ahmad
    Schlueter, Michael
    Eitel, Charlotte
    Vogler, Julia
    Kuck, Karl-Heinz
    Tilz, Roland Richard
    EUROPACE, 2022, 24 (06): : 921 - 927
  • [48] Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study
    Chen, Shaojie
    Schmidt, Boris
    Bordignon, Stefano
    Urbanek, Lukas
    Tohoku, Shota
    Bologna, Fabrizio
    Angelkov, Lazar
    Garvanski, Iskren
    Tsianakas, Nikolaos
    Konstantinou, Athanasios
    Trolese, Luca
    Weise, Felix
    Perrotta, Laura
    Chun, K. R. Julian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2724 - 2731
  • [49] Long-term clinical outcome following pulmonary vein isolation with high-intensity focused ultrasound balloon catheters in patients with paroxysmal atrial fibrillation
    Metzner, Andreas
    Chun, K. R. Julian
    Neven, Kars
    Fuernkranz, Alexander
    Ouyang, Feifan
    Antz, Matthias
    Tilz, Roland
    Zerm, Thomas
    Koektuerk, Buelent
    Wissner, Eric
    Koester, Ilka
    Ernst, Sabine
    Boczor, Sigrid
    Kuck, Karl-Heinz
    Schmidt, Boris
    EUROPACE, 2010, 12 (02): : 188 - 193
  • [50] Robotic magnetic navigation-guided catheter ablation establishes highly effective pulmonary vein isolation in patients with paroxysmal atrial fibrillation when compared to conventional ablation techniques
    Noten, Anna M. E.
    Romanov, Alexander
    De Schouwer, Koen
    Beloborodov, Vladimir
    Bhagwandien, Rohit
    Hoogendijk, Mark G.
    Mikheenko, Igor
    Wijchers, Sip
    Yap, Sing-Chien
    Schwagten, Bruno
    Szili-Torok, Tamas
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (12) : 2472 - 2483