Local catheter impedance drop during pulmonary vein isolation predicts acute conduction block in patients with paroxysmal atrial fibrillation: initial results of the LOCALIZE clinical trial

被引:51
|
作者
Das, Moloy [1 ]
Luik, Armin [2 ]
Shepherd, Ewen [1 ]
Sulkin, Matthew [3 ]
Laughner, Jacob [3 ]
Oesterlein, Tobias [3 ]
Duffy, Elizabeth [3 ]
Meyer, Christian [4 ]
Jais, Pierre [5 ]
Duchateau, Josselin [5 ]
Yue, Arthur [6 ]
Ullah, Waqas [6 ]
Ramos, Pablo [7 ,8 ]
Garcia-Bolao, Ignacio [7 ,8 ]
机构
[1] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[2] Univ Freiburg, Acad Teaching Hosp, Stadt Klinikum Karlsruhe, Med Klin 4, Karlsruhe, Germany
[3] Boston Sci Corp, Electrophysiol Dept, St Paul, MN USA
[4] Univ Hosp Hamburg, Univ Heart Ctr, Dept Cardiol, Hamburg, Germany
[5] Univ Bordeaux, CHU Bordeaux, Hop Cardiol Haut Leveque, Inst Rythmol & Modelisat Cardiaque LIRYC, Bordeaux, France
[6] Univ Hosp Southampton, Dept Cardiol, Southampton, Hants, England
[7] Clin Univ Navarra, Dept Cardiol & Cardiovasc Surg, Pamplona, Spain
[8] Navarra Inst Hlth Res, IdiSNA, Navarra, Spain
来源
EUROPACE | 2021年 / 23卷 / 07期
关键词
Radiofrequency ablation; Local impedance; Atrial fibrillation; Pulmonary vein isolation; ABLATION; RECONNECTION; FORCE;
D O I
10.1093/europace/euab004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Radiofrequency ablation creates irreversible cardiac damage through resistive heating and this temperature change results in a generator impedance drop. Evaluation of a novel local impedance (LI) technology measured exclusively at the tip of the ablation catheter found that larger LI drops were indicative of more effective lesion formation. We aimed to evaluate whether LI drop is associated with conduction block in patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI). Methods and results Sixty patients underwent LI-blinded de novo PVI using a point-by-point ablation workflow. Pulmonary vein rings were divided into 16 anatomical segments. After a 20-min waiting period, gaps were identified on electroanatomic maps. Median LI drop within segments with inter-lesion distance <= 6 mm was calculated offline. The diagnostic accuracy of LI drop for predicting segment block was assessed using receiver operating characteristic analysis. For segments with inter-lesion distance <= 6 mm, acutely blocked segments had a significantly larger LI drop [19.8 (14.1-27.1) Omega] compared with segments with gaps [10.6 (7.8-14.7) Omega, P < 0.001). In view of left atrial wall thickness differences, the association between LI drop and block was further evaluated for anterior/roof and posterior/inferior segments. The optimal LI cut-off value for anterior/roof segments was 16.1 Omega (positive predictive value for block: 96.3%) and for posterior/inferior segments was 12.3 Omega (positive predictive value for block 98.1%) where inter-lesion distances were <= 6 mm. Conclusion The magnitude of LI drop was predictive of acute PVI segment conduction block in patients with paroxysmal AF. The thinner posterior wall required smaller LI drops for block compared with the thicker anterior wall.
引用
收藏
页码:1042 / 1051
页数:10
相关论文
共 50 条
  • [21] One-year follow-up after pulmonary vein isolation using a single mesh catheter in patients with paroxysmal atrial fibrillation
    Steinwender, Clemens
    Hoenig, Simon
    Leisch, Franz
    Hofmann, Robert
    HEART RHYTHM, 2010, 7 (03) : 333 - 339
  • [22] Preprocedural Predictors of Atrial Fibrillation Recurrence Following Pulmonary Vein Antrum Isolation in Patients With Paroxysmal Atrial Fibrillation: Long-Term Follow-Up Results
    Miyazaki, Shinsuke
    Kuwahara, Taishi
    Kobori, Atsushi
    Takahashi, Yoshihide
    Takei, Asumi
    Sato, Akira
    Isobe, Mitsuaki
    Takahashi, Atsushi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (06) : 621 - 625
  • [23] Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Stabile, Giuseppe
    Solimene, Francesco
    Calo, Leonardo
    Anselmino, Matteo
    Castro, Antonello
    Pratola, Claudio
    Golia, Paolo
    Bottoni, Nicola
    Grandinetti, Giuseppe
    De Simone, Antonio
    Schillaci, Vincenzo
    Bertaglia, Emanuele
    De Ponti, Roberto
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 42 (01) : 21 - 26
  • [24] Catheter Versus Surgical Ablation of Atrial Fibrillation After a Failed Initial Pulmonary Vein Isolation Procedure: A Randomized Controlled Trial
    Pokushalov, Evgeny
    Romanov, Alexander
    Elesin, Dmitry
    Bogachev-Prokophiev, Alexander
    Losik, Denis
    Bairamova, Sevda
    Karaskov, Alexander
    Steinberg, Jonathan S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (12) : 1338 - 1343
  • [25] Incremental value of isolating the right inferior pulmonary vein during pulmonary vein isolation procedures in patients with paroxysmal atrial fibrillation
    Oral, H
    Chugh, A
    Scharf, C
    Hall, B
    Cheung, P
    Veerareddy, S
    Good, E
    Pelosi, F
    Morady, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (04): : 480 - 484
  • [26] Initial experience with zero-fluoroscopy pulmonary vein isolation in patients with atrial fibrillation: single-center observational trial
    Torma, Dalma
    Janosi, Kristof
    Debreceni, Dorottya
    Bocz, Botond
    Keseru, Mark
    Simor, Tamas
    Kupo, Peter
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [27] Prevalence, characteristics, and predictors of endocardial and nonendocardial conduction gaps during local impedance-guided extensive pulmonary vein isolation of atrial fibrillation with high-resolution mapping
    Nakamura, Kohki
    Sasaki, Takehito
    Minami, Kentaro
    Take, Yutaka
    Inoue, Mitsuho
    Sasaki, Wataru
    Kishi, Shohei
    Yoshimura, Shingo
    Okazaki, Yoshinori
    Motoda, Hiroyuki
    Niijima, Katsura
    Miki, Yuko
    Goto, Koji
    Kaseno, Kenichi
    Yamashita, Eiji
    Koyama, Keiko
    Funabashi, Nobusada
    Naito, Shigeto
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (08) : 2045 - 2059
  • [28] Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden The RACE-AF Randomized Controlled Trial
    Sorensen, Samuel K.
    Johannessen, Arne
    Worck, Rene
    Hansen, Morten L.
    Hansen, Jim
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (05) : 523 - 532
  • [29] Initial clinical experience with the novel POLARx FIT cryoballoon system for pulmonary vein isolation in patients with atrial fibrillation
    Fukunaga, Hiroshi
    Sekiguchi, Yukio
    Sawaguchi, Jun
    Hayashi, Yosuke
    Asano, Sou
    Mabuchi, Kei
    Inoue, Kanki
    Tanizaki, Kohei
    Umemura, Jun
    Isobe, Mitsuaki
    Nitta, Junichi
    IJC HEART & VASCULATURE, 2024, 50
  • [30] Circumferential Pulmonary Vein Ablation With Additional Linear Ablation Results in an Increased Incidence of Left Atrial Flutter Compared With Segmental Pulmonary Vein Isolation as an Initial Approach to Ablation of Paroxysmal Atrial Fibrillation
    Sawhney, Navinder
    Anousheh, Ramtin
    Chen, Wei
    Feld, Gregory K.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (03) : 243 - 248