Reduced-scan schemes for x-ray fluorescence computed tomography

被引:13
|
作者
La Riviere, Patrick J. [1 ]
Vargas, Phillip
Newville, Matt
Sutton, Stephen R.
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Ctr Adv Radiat Sources, GSECARS, Argonne, IL 60439 USA
[3] Univ Chicago, Dept Geophys Sci, Chicago, IL 60637 USA
基金
美国国家科学基金会;
关键词
image reconstruction; penalized-likelihood; methods; X-ray fluorescence computed tomography;
D O I
10.1109/TNS.2007.906167
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
X-ray fluorescence computed tomography (XFCT) is a synchrotron-based imaging modality employed for mapping the distribution of elements within slices or volumes of intact specimens. A pencil beam of external radiation is used to stimulate emission of characteristic X-rays from within a sample, which is scanned and rotated through the pencil beam in a first-generation tomographic geometry. The measurements so obtained can be represented as generalizations of the attenuated Radon Transform. The range of angular scanning employed is the subject of some variability in the XFCT imaging community, as some groups rotate the object through a full 360 degrees, while others employ only a 180 degrees rotation. In both cases, the entire object is scanned through the beam at each projection view. The use of a 180 degrees rotation is sometimes justified by implicit reference to a well-known symmetry property of the Radon transform, but that symmetry does not hold for the attenuated Radon transform. In this work, we demonstrate that a full scan of the object at each view coupled with a 360 degrees rotation does contain a two-fold data redundancy. While the redundancy does not give rise to a simple symmetry condition as in the case of the Radon transform, we will show that it does indeed license the use of the 180 degrees scheme. However, we will also demonstrate that when there is a single external fluorescence detector, the redundancy also licenses a potentially more attractive reduced-scan scheme, in which the object is rotated through a full 360 degrees, but in which only the half of the object closest to the fluorescence detector is scanned at each projection view. This new scheme may permit both reduced imaging times and improved image quality.
引用
收藏
页码:1535 / 1542
页数:8
相关论文
共 50 条
  • [31] Automatic Parameter Tuning for X-ray Computed Tomography Reconstruction
    Liu, Li
    Lin, Weikai
    Jin, Mingwu
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [32] X-ray source translation based computed tomography (STCT)
    Yu, Haijun
    Li, Lei
    Tan, Chuandong
    Liu, Fenglin
    Zhou, Rifeng
    OPTICS EXPRESS, 2021, 29 (13) : 19743 - 19758
  • [33] Scattering Noise Model Enhanced EM-TV Algorithm for Benchtop X-ray Fluorescence Computed Tomography Image Reconstruction
    Zhang, Siyuan
    Li, Liang
    Chen, Zhiqiang
    IEEE ACCESS, 2019, 7 : 113589 - 113595
  • [34] Deep Interactive Denoiser (DID) for X-Ray Computed Tomography
    Bai, Ti
    Wang, Biling
    Nguyen, Dan
    Wang, Bao
    Dong, Bin
    Cong, Wenxiang
    Kalra, Mannudeep K.
    Jiang, Steve
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (11) : 2965 - 2975
  • [35] A Stopping Criterion for iterative reconstruction of X-ray computed tomography
    Yang, Yirong
    Liang, Kaichao
    Xing, Yuxiang
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [36] Fast optimization of coded apertures in X-ray computed tomography
    Mao, Tianyi
    Cuadros, Angela P.
    Ma, Xu
    He, Weiji
    Chen, Qian
    Arce, Gonzalo R.
    OPTICS EXPRESS, 2018, 26 (19): : 24461 - 24478
  • [37] A general method for motion compensation in x-ray computed tomography
    Biguri, Ander
    Dosanjh, Manjit
    Hancock, Steven
    Soleimani, Manuchehr
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16) : 6532 - 6549
  • [38] X-ray computed tomography using sparsity based regularization
    Liu, Li
    Lin, Weikai
    Pan, Jing
    Jin, Mingwu
    NEUROCOMPUTING, 2016, 173 : 256 - 269
  • [39] Fluorescence background subtraction technique for hybrid fluorescence molecular tomography/x-ray computed tomography imaging of a mouse model of early stage lung cancer
    Ale, Angelique
    Ermolayev, Vladimir
    Deliolanis, Nikolaos C.
    Ntziachristos, Vasilis
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [40] Quantitative X-ray phase contrast computed tomography with grating interferometry Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography
    Birnbacher, Lorenz
    Braig, Eva-Maria
    Pfeiffer, Daniela
    Pfeiffer, Franz
    Herzen, Julia
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (13) : 4171 - 4188